Do you have a question about the ES10 and is the answer not in the manual?
Questions and answers
Summary of Contents for AVICHE ES10
Page 1
User Manual Automatic Digital Blood Pressure Monitor Version 2.0 ES10 Attention: The user manual is in the packaging, please read all instructions before using and keep them properly for later use. Issued time: January, 2019...
Page 3
Introduction Thank you for purchasing our product. It is used to measure human blood pressure and pulse, help people to know their health status. With automatic control measurement technique, This digital blood pressure monitor will inflate intelligently according to people's systolic pressure and arm circumference, reducing the uncomfortable feeling caused by excessive pressure.
Table of Contents ……………………………………………………… Unit Description ……………………………………………………… Icons in Display ……………………………… Inserting and Replacing Batteries ………… Setting Date, Time, Voice, Unit, and Alarm Clock …………………………………………… Setting Memory Space ………………………………………………… Measuring Position ………………………………………………………… Fitting the Cuff ……………………………………… Measuring Blood Pressure …………………………………………………… Reading Memory ……………………………………………………...
Unit Description LCD Display Power Button (START/STOP) Cuff Socket Memory Button Setting Button (MEM) (SET) Adapter Socket (USB Type-C) Voice Broadcast Cuff Connector Cuff Attention if use AC adapter 1. If user needs to purchase the adapter, please refer AC adaptor to the specifications shown on the right figure.
Icons in Display Memory group Date/Time Voice broadcast Systolic pressure Blood pressure classification Diastolic pressure Memory number Pulse Display Symbols Storing or reading memory symbol Low battery symbol, replacing battery Alarm clock Hypertension classification Voice function Pulse symbol Memory group 1 Memory group 2 Average of latest 3 readings Inflating error...
Inserting and Replacing Batteries 1. Remove the battery compartment lid according to the arrow direction. 2. Insert 4pcs AA batteries with correct polarity, then put on the battery cover. Attention: 1. Replace the batteries when indicating low battery symbol or no display after switching on machine.
Setting Date, Time, Voice, Unit, and Alarm Clock Right time setting can help you to record every measurement time correctly. 1. Press button for 3 seconds, then enter the setting interface, the year in display starts to flash (Figure 1). 2.
Page 10
6. mmHg and kPa unit conversion setting. After setting the voice, it will automatically enter the unit setting and user can press button to adjust mmHg to kPa. 7. 3 groups of alarm clock remind you to measure blood pressure on time, after unit setting it automatically enter A1 alarm setting, press to adjust ON or OFF, press button to confirm, after finish...
Setting Memory Space 1. Press button to choose memory Measuring Position Take a seat and two feet flat on the floor, place your arm on the table comfortably, palms up, ensure that the arm cuff is at heart height. Keep still and do not talk during the measurement.
Fitting the Cuff 1. Open arm cuff, slide the open end of cuff through the metal bracket so that the velcro fastener is on outside, insert the cuff tube connec- tor solidly into blood pressure monitor body. 2. Slide the cuff over the left upper arm, wrapped the arm cuff tightly, artery indicator close to artery of upper arm (the inner arm).
Measuring Blood Pressure 1. Wrap the arm cuff properly on the arm (refer to cuff using). 2. Press button display full screen, ready to measure. 3. Press button to start measuring, the device will inflate until the pressure is suitable for you, and then deflate, keep still and quiet during measurement.
Reading Memory 1. When you press button, the first display is the average of the latest 3 measured value. 2. Press button again, it will display the record of the previous time. Deleting Memory 1. Press button for 3 seconds, all records will be deleted. Attention: 1.
Blood Pressure Knowledge What is the blood pressure ? Blood pressure is the pressure exerted by circulating blood upon the walls of blood vessels, which refers to systolic pressure and diastolic pressure. Systolic pressure is the highest pressure output by blood during systole.
Safety Cautions 1. Battery leakage may damage the machine body, remove the batteries if the product will not be used for a long time. 2. The product is not allowed to use on infants and young children. 3. Do not inflate before wrapping the cuff. 4.
9. There may be risk if the air bag is over inflated for a long time. 10. When common arrhythmia (such as atrial premature, premature ventricular, atrial fibrillation) appears, measured values may not be accurate or blood pressure can't be measured. The accuracy of this monitor has been rigorously tested.
Maintenance 1. Please keep the blood pressure cuff and accessories in the saving bag when not using. 2. In order to avoid the damage of the device, do not expose the blood pressure monitor and cuff to high temperature, humidity, full of water vapor or direct sunlight.
Specification Product name Automatic Digital Blood Pressure Monitor Model number ES10 Power supply 4 “AA” batteries 1.5V or USB power line (Type-C) Measuring method Oscillometric method Pressure: 0 to 280 mmHg (0-37.3kPa) Measure range Pulse: 40 to 199 beats/min Pressure: ±3 mmHg (±0.4kPa) Accuracy Pulse: ±5% of display reading...
EMC Declaration Guidance and manufacturer's declaration - electromagnetic immunity The “blood pressure monitor” is intended for use in the electromagnetic environment specified below. The customer or the user of the “blood pressure monitor” should ensure that it is used in such an environment. IEC 60601 Compliance Electromagnetic environment...
Page 21
IEC 60601 Compliance Electromagnetic environment Immunity test test level level — guidance Portable and mobile RF communica- tions equipment should be used no closer to any part of the “blood pressure monitor”, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.
Page 22
Guidance and manufacturer's declaration - electromagnetic emissions The “blood pressure monitor” is intended for use in the electromagnetic environment specified below. The customer or the user of the “blood pressure monitor” should ensure that it is used in such an environment. Electromagnetic environment Compliance Emissions test...
Page 23
Recommended separation distances between portable and mobile RF communications equipment and the blood pressure monitor The “blood pressure monitor” is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the blood pressure monitor can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the “blood pressure monitor”...
Page 24
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
After-safes Service and Warranty Card 1. Implement the national policy of Three Guarantees. 2. Free maintenance will be provided by AVICHE in case of quality problems within one year from the date of purchase. In case of such issues over one year, Users can seek services by right of invoice and...
Page 30
2. Spare Parts Spare parts will be provided free of charge within the warranty period, and is subject to charges out of warranty period. 3. Contact Information for After-sales Service Service Hotline: +86-400-800-9850 AVICHE Shandong Medical Technology Co., Ltd.
Page 32
Of AVICHE Production date: See the label on the bottom of monitor Service life: 2 years Distributed by: AVICHE Shandong Medical Technology Co., Ltd. Manufacturer: AVICHE Shandong Medical Technology Co., Ltd. Address: Floor 26, Building A, A2-1 Jinan Pharm Valley, Gangxingsan Road, High-tech District, Jinan City, Shandong Province, China.
Need help?
Do you have a question about the ES10 and is the answer not in the manual?
Questions and answers