Page 1
Aqua-X Irrigation Control System The default function of Water Dectector (WD-1) is for leak detection and there is a triangle symbol shown in the LCD display of the Aqua-X Controller. When the WD-1 detects water leakage, it will send alarm message to your Smartphone one minute later.
Installation Mount the water detector near the water reservoir or nutrient tank. Use a screw to mount the Water Detector on the wall or fix it through the top hole with a string.
Page 4
Operation Instructions 1. Connection to Aqua-X Connect the RJ12 cable ( left ) to the Water Detector terminal on the bottom panel of the Aqua-X Controller. The touch spot cable ( right ) can be used to be connected to a single TSS-1 Touch Spot ( sold separately ) or use a T-Splitter to connect one more TSS-1 Touch Spot under one Water Detector.
2. Address Assignment Press the Addressing button on the WD-1unit so that the Aqua-X Controller will assign an address to the WD-1 unit accordingly. The LCD screen of the WD-1 Water Detector will show a triangle symbol indicating that the water leak...
Page 6
Detector will be marked as number 1, and the second is number 2 and so on. a. Leak Sensor ( Leak Detection Mode) The default function of Water Detector (WD-1) is for leak detection and there is a triangle symbol shown in the LCD display of the Aqua-X Controller. When WD-1 detects water leakage, it will send an alarm message to your Smartphone one minute later.
Page 7
If the Water Detector is NOT in original default function ( leak sensor ), you can change the Assignment into Leak Sensor as above processes. b. Assignment ( Output Assigned Mode ) The default mode of Water Detector is in Leak Sensor ( Leak Detection Mode). You can change the Leak Detection Mode ( Leak Sensor ) into Output Assigned Mode ( Assignment ) as below processes.
Page 9
NOTE : 1. Each Water Detector can be assigned to a Control Board which has been successfully assigned to the Aqua-X Controller. The Water Detector can not be assigned to an unassigned Control Board. 2. One Water Detector can be assigned to only one 24V or 110V output. One Aqua-X Controller can connect up to 30pcs Water Detectors.
Need help?
Do you have a question about the WD-1 and is the answer not in the manual?
Questions and answers