Page 1
SERVICE MANUAL EIS 165.3 N/P KW (short version) inglese EIS 165.3 N/P KW Service Manual (short version) EIS 165.3 N/P KW Service Manual Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
2.2. REFRIGERATION DIAGRAM FOR DEFROST CYRCLE EIS 165.3 N/P KW 2.3. VIEW OF MOTOR COMPARTMENT – EIS 165.3 N/P KW 2.4. VIEW OF THE EVAPORATOR COMPARTMENT - EIS 165.3 N/P KW 3. POSITION OF PROBE IN THE CABINET 4. ALARMS FOR EIS 165.3 N/P KW (Dixell Controller) 5.
39g/m Striking will not cause 100% flames If the entire amount of refrigerant is released in the chest of a EIS 165.3 N/P KW, this would be a flammability zone event. Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
GROUP 1 – LEFT SIDE – REFRIGERANT CHARGE 130g Point into which nitrogen needs to be blown to remove propane from the pipework. Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
Page 5
GROUP 2 – CENTRAL SIDE – REFRIGERANT CHARGE 140 g Point into which nitrogen needs to be blown to remove propane from the pipework. Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
The open solenoid valve runs gas through the drip trough and then sends it straight to the evaporator. GROUP 1 Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
Page 7
SERVICE MANUAL EIS 165.3 N/P KW (short version) inglese GROUP 2 Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
VIEW OF MOTOR COMPARTMENT – REAR SIDE FRAME HEATING PIPE COMPRESSOR COMPRESSOR EVAPORATING WATER TRAY FILTER DRYER INVERTER INVERTER FILTER DRYER SOLENOID VALVE SOLENOID VALVE Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
Function Probe Epta code Colour Evaporator Yellow Defrost I0205786 EIS 165 N/P KW Tank – motor compartment Grey Display - Thermostat I0205805 Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
In order to achieve this, three general guidelines should be followed during servicing: F1. Containment of the substance; F2. Avoidance of ignition sources; F3. Use of ventilation. Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
DO NOT WORK WITH OPEN FLAMES BEFORE THE PIPEWORK HAS BEEN CUT! ‐ REMOVE ALL SPARK SOURCES FROM THE WORK AREA (LIGHTERS, LAMPS, ‐ CIGARETTES). PROTECTION TOOLS AND DEVICES FOR SERVICING Protection tools: Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
Page 12
ELECTRONIC LEAK DETECTOR REFRIGERAT JUNCTIONS LOCKRING JOINT PLIER LOCKRING JOINT WITH CLOSED SIDE REFRIGERANT GAS BOTTLE NITROGEN GAS BOTTLE Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
Page 13
SERVICE MANUAL EIS 165.3 N/P KW (short version) inglese REFRIGERANT SCALE VACUUM PUMP LOKPREP SEALANT ORBITAL CUTTER SCREWDRIVER WRENCH n°10 Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
CIRCUIT IN SUCH A QUANTITY TO BE DANGEROUS WHEN FLAMES OR HEAT SOURCES ARE USED. Also cut the pipe entering the filter and replace the filter dryer with a new one. Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
After being that no more refrigerant gas is inside the thermodynamic circuit, unsolder from compressor the charge pipe (A), the suction pipe (1) and the discharge pipe (2). Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
After 30-40 minut of vacuum operation, disconnect the vacuum machine only on the high pressure pipe (B). Take the plier (3) and pinch the high pressure pipe (B), then remove refrigerant junction. Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
Page 17
Insert lockring joint (5) on the high pressure pipe (B). Rotate the joint (5) for correctly distribute the sealant (4). By using the lockring plier (6) fix joint (5) on the copper pipe (B). Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
The refrigerator must be ON for 5-6 minutes, then disconnect the refrigerator from current. Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
Page 19
Put a drop of Lokprep sealant (4) on the low pressure pipe (A). Insert lockring joint (5) on the low pressure pipe (A). Rotate the joint (5) for correctly distribute the sealant (4). Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
‐ End of high pressure pipe (lockring joint). ‐ End of low pressure pipe (lokring joint). ‐ Suction pipe welding. ‐ Charge pipe welding. ‐ Discharge pipe welding. Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
REPLACEMENT OF EVAPORATOR MOTOR FAN 5.12 1 – Unscrew and remove evaporator cover. 2 – Disconnect the motor fan connectors. 3 – Unscrew and remove the motor fan. Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
Epta code Solenid Valve: I0189033 Model: SOLENOID VALVE EVR3 115/60 U.L. Epta code Mechanic filter: I0145001 Model: MECHANIC FILTER D.MM17X74 Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
LED BARS Epta code for LED lamp: I0225233 – LED LAMP SV‐FPP54‐3014/50‐6500‐128416 REPLACEMENT OF TEMPERATURE SWITCH 5.17 1) Unscrew and remove upper command panel. 2) Disconnect and remove the temperature switch Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
REPLACEMENT OF DOOR AND DOOR GASKET 5.19 1) Unscrew and remove upper command panel. 2) Unscrew the bumper. Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
Page 25
3) Unscrew the front grid. 4) Open the fasteners and disconnect the connectors. 5) Disconnect the wires from connectors. Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
Page 26
WARNING! Pay utmost attention during next steps; so as avoid the fall of the door. 7) Unscrew and remove upper door support. 8) Unscrew the door hinge screw. Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
Page 27
10) Insert the wires into the lower frame (shown as in picture) through the fairlead ring. 11) Insert again the door. Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
Page 28
13) Insert and screw the upper door support (use the same screws previously removed). 14) Insert the wires in the connectors previously removed. Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
Page 29
17) Remove the magnetic gasket from door frame, pulling it out manually from its housing. Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
Position of probe Probe Epta code Colour Evaporator Yellow I0205786 Tank – motor compartment Grey I0205805 Remove Disconnect Remove Disconnect Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
SERVICE MANUAL EIS 165.3 N/P KW (short version) inglese REPLACEMENT OF DEFROST HEATER 5.21 Remove Remove Disconnect REPLACEMENT OF DOOR HANDLE 5.22 Unscrew Unscrew Unscrew Unscrew Unscrew Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
SERVICE MANUAL EIS 165.3 N/P KW (short version) inglese REPLACEMENT OF SHELF RACK 5.24 Unscrew Unscrew Unscrew Unscrew Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
To exit: press both SET+UP keys or wait for 15 sec without pressing any key. NOTE: the set value is stored even when the procedure is exited by waiting the time-out to expire. Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
SERVICE MANUAL EIS 165.3 N/P KW (short version) inglese EIS 165.3 N/P KW PARAMETERS Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
Only if the average internal temperature is too cold or not cold you can increment or decrement the temperature: Press the (Set) (2 sec.) key in order to see on display the temperature set point. Press the () key or the () key in order to increment or decrement the temperature set point. Press the (Set ) key in order to store the new temperature set point. Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
DOOR FRAME HEATER DOOR GLASS HEATER DECOMPRESSION VALVE HEATER POSITIVE TEMP. RANGE LIGHT ISOLATION TRANSFORMER DEFROSTING VALVE VS / VS1 Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
SERVICE MANUAL EIS 165.3 N/P KW (short version) inglese WIRING DIAGRAM Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
Check that internal fans are correctly running; if not, check top switches and connectors inside the carter. Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
Page 40
Picture example of motor compartment Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
PRESENCE OF WATER ON THE FLOOR OR ABNORMAL ICE INSIDE THE TANK Check alignment of the cabinet by means of adjustable feet. Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
Page 42
Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
Obstruction or incorrect circuit cleaning: initial part of capillary tube shows ice or frost. Leakage: check with a HC-compatible detector. Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
The electronic unit has 2 LED’s which can be observed when the cable cover is removed. In case of a failure, the red LED sends a sequence of light pulses, that relates to the failure Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
Page 45
Defect electronic Electronic over-heated Insufficient airflow or load too high. Input signal failure Input frequency out of range. Frequency signal either distorted or above 200Hz Autori: Serralunga M. 14/10/2021 NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT...
Need help?
Do you have a question about the EIS 165.3 N/P KW and is the answer not in the manual?