Sink Tray Sump Basin
Description
Sink Tray Sump Basin, Model number PS51-1P, is ideal
for home wastewater removal from sinks, wet bars, wash-
ing machines and laundry tubs, or for drain water transfer
from air conditioners and dehumidifiers. The molded poly-
ethylene seamless basin comes with a bolt down lid with
threaded inlet and vent connections and water and gas
tight uniflex fittings.
Specifications
Capacity................................................10 Gallons Minimum
Inlet.......................................................................1-1/2" NPT
Discharge ..........................................1-1/4" or 1-1/2" Uniflex
Vent.........................................................................2" Uniflex
Dimensions:
Length ...............................................................................17"
Width...........................................................................11-3/4"
Height................................................................................14"
Weight............................................................................9 lbs.
Installation
(See Figure 1)
NOTICE: The basin (system) should be located at the low-
est place possible relative to the area to be drained.
Vent Pipe
2" Uniflex Vent Fitting
Cord grommet
Capscrews and Washers
(8 of each)
Basin Cover
Gasket
10-Gallon water basin
with cover & gasket
Vertical Float Switch
14"
(355.6mm)
17"
(431.8mm)
Figure 1 - Sink Tray Sump Basin System Diagram.
1. Place the pump with an in-line check valve in the basin.
2. Remove the paper backing from the gasket and install
3. Run the electrical cords through the hole in the cover as
4. Install the discharge grommet in the cover, lip up.
5. Slip this end of the discharge pipe into the upper end of
6. Work the cover assembly down the discharge pipe until
7. Gently pull the slack out of electrical cords.
8. Install the vent grommet, larger diameter of fitting up.
9. Lubricate the vent pipe with soapy water and insert the
10. Install the inlet pipe into the basin opening. Use
*E.I. DuPont DE Nemours and Company Corporation, Wilmington Delaware, 19898
Discharge
pipe
1-1/4" or 1-1/2"
Uniflex Fitting
Hose
(not included)
1-1/2" Inlet Fitting
Check valve
(not included)
Drainer Pump
11.75"
(299mm)
Figure 2 -Typical installation to remove air conditioner
2427 0596 IS
condensate or humidifier water.
Attach the discharge hose to the check valve.
the gasket around the edge of the opening in the basin,
sticky side down. Do not cover the threaded inserts.
shown. Slip the cord grommet over the cords and install
the grommet in the cover, lip side up.
Lubricate the discharge pipe with soapy water and insert
the pipe 10" - 12" through the grommet.
the hose. Secure both ends of the hose with hose
clamps.
the cover is seated on the basin. Tighten the cover
down on the basin with the 8 capscrews and washers.
Compress the gasket material, but do not overtighten.
vent pipe into the vent grommet. The pipe should
extend no more than 2" into the basin. Connect the vent
pipe to sewer vent system.
Teflon™ tape to seal the pipe threads. For typical instal-
lation arrangements see Figures 2, 3, and 4.
NOTICE: Do not use ordinary pipe joint compound on
plastic pipe. Pipe joint compound can attack plastics.
Air Conditioner
or Dehumidifier
Sink Basin
and Pump
Discharge
Pipe
Vent
Pipe
3272 0698 IS
PW80-45 (1/23/02)

Advertisement

loading

Summary of Contents for Pentair PS51-1P

  • Page 1 1. Place the pump with an in-line check valve in the basin. Attach the discharge hose to the check valve. Sink Tray Sump Basin, Model number PS51-1P, is ideal 2. Remove the paper backing from the gasket and install for home wastewater removal from sinks, wet bars, wash-...
  • Page 2 11. Check system operation by filling the basin with water and observing system operation through one complete cycle. Risk of Flooding. Flooding can cause Discharge Pipe personal injury or property damage. Failure to make this operational check may lead to improper operation, premature failure, and flooding.To avoid flooding, wash- Vent to Sewer Vent System...