Do you have a question about the SenTRI SEN-720 and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for SMS SenTRI SEN-720
Page 1
Data and installation Sensor, Sounder & Strobe range General specification Operating voltage 35V - 41V Weight 110g with base - 170g SEN-720 only: 88g (with base - 148g) Dimensions in mm 117 diameter by 49.6 height With base the height increases to 63.8 These instructions are for the SenTRI Sensor product range.
Page 2
Data and installation Sensor, Sounder & Strobe In - Out wiring to Sensor bases Siting A Sensor, Sounder & Strobe device plugs into a dedicated Base that is installed in the protected premises. The Bases should be sited in locations as defined by the project plans and by OUT5 OUT5 BS5839 : Part 1 : 2002.
Page 3
Sensor, Sounder & Strobe Data and installation To fit the dust cover using tool Tools Place the dust cover onto the tool inside the cradle. Offer the cover to the SenTRI device, locate and push to fit it onto the An extractor tool allows removal and fitting of the Sensor device assembly.
Page 4
0832 SenTri Base Locate the SenTri Base into SMS by Honeywell (Novar Systems Limited) Manufactured by: Honeywell Life Safety Systems, the flush shroud, such that the 140 Waterside Road, Hamilton Industrial Park, two locating pillars on the...
Page 5
Description and Commissioning information Sensor, Sounder & Strobe range Base Sensor Sounder Strobe device Base label (optional) Base The base has terminals for external cables to allow it to be electrically connected to the panel loop circuit and to the monitored input or output circuit.
Page 6
Description & Commissioning Sensor, Sounder & Strobe Monitoring Sounder (S) Under normal conditions the Sensor, Sounder & Strobe devices The sounder function in a Sensor, Sounder & Strobe device is are monitored regularly and the data is used to create a designed to meet the requirement of EN54 : Part 3.
Page 7
Sensor, Sounder & Strobe Description & Commissioning Compatibility At the time of releasing this data sheet the Sensor, Sounder & Strobe devices were compatible for installation on the loop circuits of fire alarm system based on panels having the following cards: ³...
Page 8
Description & Commissioning Sensor, Sounder & Strobe Sensor, Sounder & Strobe device STATES The STATE in which a Sensor device operate can be changed from the default factory set STATE to another STATE during commissioning. The environment in which a Sensor, Sounder & Strobe device is installed will determine what STATE is used. # - factory default settings LPCB approved...
Page 9
Sensor, Sounder & Strobe Description & Commissioning Optical & Heat sensor STATES Sensitivity STATE Definition / Class Application in / Suitable for: a-high- to-j-none STATE 3 High sensitivity optical, Clean area or environment, where early detection Class A1 heat is required STATE 4 Medium sensitivity with no General area as STATE 0 with less immunity to...
Page 10
Description & Commissioning Sensor, Sounder & Strobe Sensor, Sounder & Strobe device Status How to view Sensor, Sounder & Strobe device Status To view the status of a Sensor, Sounder & Strobe device following the allocation of the loop circuit on which it is installed.
Page 11
Sensor, Sounder & Strobe Description & Commissioning How to check Sensor, Sounder & Strobe device Exception codes The Exception codes are also sometimes called condition codes and these codes provide information about a sensor device. A code indicates small changes in the: ¨...
Page 12
Description & Commissioning Sensor, Sounder & Strobe How to interpret Exception Codes Exceptions Meaning Action /Condition codes This is the sub-fire band and if set should be No action need be taken. 1 0 0 0 0 0 0 0 0 0 or taken as showing that the sensor is at its optimum 0 1 0 0 0 0 0 0 0 0 or sensitivity for its location.
Page 13
Sensor, Sounder & Strobe Description & Commissioning Exception (or Condition) Codes for Sensor, Sounder & Strobe devices Exception codes normal sub fault band fault band band type Description Optical None Small signal Subfire subfire sensed [Check location, [Check STATE & type] location, STATE &...
Page 14
Description & Commissioning Sensor, Sounder & Strobe Sensor, Sounder & Strobe devices - Time average reading The typical time average values for sensors under normal operating condition are shown in the table below. Part No Product Analogue Channels Time average Tnew SEN-720 Heat Sensor 2 - heat...
Page 15
Sensor, Sounder & Strobe Description & Commissioning Sensor, Sounder & Strobe devices - Message Action List This list shows the messages that are likely to be displayed at the control panel or at a loop repeat panel in the fire system. Message Action list The messages displayed at the control panel or loop repeat panels are given for guidance only: ¨...
Page 16
Description & Commissioning Sensor, Sounder & Strobe Finding a Sensor, Turbo and Non Turbo Sounder & Strobe Modes device The Sensor, Sounder & Strobe devices can output in turbo and/or in non turbo modes. When the panel commands a low or The 'find device' is a function that gives a visual or audible high tone output at Sensor, Sounder &...
Sensor, Sounder & Strobe Description & Commissioning Engineering password is set up. Press <etc> and System test select [Test] and select [Zone] and toggle select [Reset / No Reset], whatever it reads that is what Preparation is selected. Now select [On] and type in the zone number and select [Enter].
Page 18
Description and Commissioning Sensor, Sounder & Strobe Commissioning tool settings Menu selection Icon selection Attention tone Speech Message Configuration Standard Complex Message tone SenTRI Config... To select line type: Sounder or Speech and - Unmonitored output Strobe enable / disable - Monitored input or - Monitored output High and Low tone selection or...