Summary of Contents for Feig Electronic OBID i-scan HF LRM2500
Page 1
INSTALLATION Reader LRM2500 with an- tenna ID ISC.ANT1800/700 customized (E) 2013-04-09 –M00910-8e-ID-B-ANATEL.doc...
Page 2
FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a human.
Page 3
• The following figure formats are used: 0...9: for decimal figures 0x00...0xFF: for hexadecimal figures, b0...1 for binary figures. • The hexadecimal value in brackets "[ ]" marks a control byte (command). FEIG ELECTRONIC GmbH Seite 3 von 69 M00910-8e-ID-B-ANATEL.doc...
Setting the Multiplexer ......................30 Setting the Antenna Tuner ....................31 Interface Connections ......................32 RS 232 ........................32 LAN / TCP/IP ......................33 Reader Configuration with Multiplexer ................. 34 Tuning the Gate Antenna ..................... 37 FEIG ELECTRONIC GmbH Seite 4 von 69 M00910-8e-ID-B-ANATEL.doc...
Page 5
USA (FCC) and Canada (IC) ....................64 Antenna ID ISC.ANT1800/700 ..................64 People Counter ID ISC.ANT1800/700-GPC ..............65 USA and Canada (UL) ......................66 Annex A Terminal assignment “Terminal Board” ................67 Internal wiring ......................... 69 FEIG ELECTRONIC GmbH Seite 5 von 69 M00910-8e-ID-B-ANATEL.doc...
Page 6
• CAUTION! Do not look directly into the LED light. There is a danger of injury of the eyes! FEIG ELECTRONIC GmbH Seite 6 von 69 M00910-8e-ID-B-ANATEL.doc...
Page 7
Do not try to open the antenna during operation or outside maintenance periods. Non- professional management can result in damage to the device. If any device not working properly, please contact the appropriate representative. FEIG ELECTRONIC GmbH Seite 7 von 69 M00910-8e-ID-B-ANATEL.doc...
Page 8
Even after the unpacking of the antennas the face of the antenna plate must be always transported and stored vertically. A transport in horizontally oriented antenna can deform the antenna plate. FEIG ELECTRONIC GmbH Seite 8 von 69 M00910-8e-ID-B-ANATEL.doc...
After tuning, the antennas will retain their settings as long as the ambient conditions remain unchanged. The antennas can be used for detecting both product and persons. It is for indoors use, only. FEIG ELECTRONIC GmbH Seite 9 von 69 M00910-8e-ID-B-ANATEL.doc...
A change of the counter values will be stored in the EEPROM of the People Counter board. By sending the command “0x78 Set People Counter” the values could be set/reset to the needed value. FEIG ELECTRONIC GmbH Seite 10 von 69 M00910-8e-ID-B-ANATEL.doc...
Page 11
The three digital output can be used, to enable a signal light at every gate antenna or activate an alarm buzzer in the gate antenna. FEIG ELECTRONIC GmbH Seite 11 von 69 M00910-8e-ID-B-ANATEL.doc...
Page 12
In ISO Host or Buffered Read Mode, the host poll the GPC by sending protocols. Only, in the Noti- fication Mode, the reader poll the counter values, automatically, and send data according the read- er configuration to the host. See also System Manual H01011-0e-ID-B.DOC FEIG ELECTRONIC GmbH Seite 12 von 69 M00910-8e-ID-B-ANATEL.doc...
Number of ID ISC. ID ISC. ID ISC. ID ISC.ANT. Note antennas ANT1800/700 ANT1800/700 ANT1800/ GPC-E 700-GPC 2 Antennas 3 Antennas 4 Antennas Table 2 Required components for gates with People Counter FEIG ELECTRONIC GmbH Seite 13 von 69 M00910-8e-ID-B-ANATEL.doc...
The antennas must have a minimum distance of 20 cm to all larger metal parts! At a distance of less than 50 cm between the antenna and metal parts the read range will be significantly reduced. FEIG ELECTRONIC GmbH Seite 14 von 69 M00910-8e-ID-B-ANATEL.doc...
(hexagon socket width AF 2,5) have to remove of the antenna base cover. By moving the cover upwards, carefully, remove the cover from the antenna base. Fig. 4 Step 1 Step 2 Fig. 4: Opening the antenna base FEIG ELECTRONIC GmbH Seite 15 von 69 M00910-8e-ID-B-ANATEL.doc...
Dimensions of antenna The overall dimensions of the antenna are shown in Fig. 5 Fig. 5: Antenna outside dimensions All dimensions are in mm with general tolerance according to ISO 2768 m (mean). FEIG ELECTRONIC GmbH Seite 16 von 69 M00910-8e-ID-B-ANATEL.doc...
A cable opening is provided for the necessary connection cable (see Fig. 6). The cable opening is dimensioned such as up to 10 cables having a diameter of 6 mm can be passed through the opening. FEIG ELECTRONIC GmbH Seite 17 von 69 M00910-8e-ID-B-ANATEL.doc...
Page 18
® OBID i-scan Installation LRM2500 Alternatively the cables can be routed at the sides of the antenna bas like shown in Fig. 7 Fig. 7 Cable routing at the antenna sides FEIG ELECTRONIC GmbH Seite 18 von 69 M00910-8e-ID-B-ANATEL.doc...
Gate People Counter 0 Project Notes People Counter (GPC). Fig. 8 Conductors shape have to have same direction Adjusting screws (hexagon socket width AF 4) Fig. 9: Attaching and aligning the antenna FEIG ELECTRONIC GmbH Seite 19 von 69 M00910-8e-ID-B-ANATEL.doc...
To get a optimal performance the reader has to be configured and run in one of the Automatic Modes (Buffered Read, Notification or Scan Mode). FEIG ELECTRONIC GmbH Seite 20 von 69 M00910-8e-ID-B-ANATEL.doc...
Page 21
(see Table 5: ). The number of tags may be increased in the gate distance GD is correspondingly reduced and the maximum speed adjusted accordingly. The antenna should be at least 50 cm away from metal parts. FEIG ELECTRONIC GmbH Seite 21 von 69 M00910-8e-ID-B-ANATEL.doc...
Page 22
Electrical cable, directly at the antenna or in the immediate vicinity of the antenna, can be cause interference. A minimum distance of 20 cm is required. A minimum distance of 65cm between the two gate antennas is required. FEIG ELECTRONIC GmbH Seite 22 von 69 M00910-8e-ID-B-ANATEL.doc...
/ masonry . Antenna wall / masonry Type -A Fig. 12: Top: Detection area A1 und A2 (Foot print) of the radar sensor FEIG ELECTRONIC GmbH Seite 23 von 69 M00910-8e-ID-B-ANATEL.doc...
Page 24
If greater deviations are found, at first, the sensitivity of the radar sensors should be reduced stepwise. FEIG ELECTRONIC GmbH Seite 24 von 69 M00910-8e-ID-B-ANATEL.doc...
DATuningTool Version 1.10 or higher ® ® on a personal computer running under Microsoft Windows . The service can be downloaded at the Download Area of the Homepage www.feig.de. FEIG ELECTRONIC GmbH Seite 25 von 69 M00910-8e-ID-B-ANATEL.doc...
DC Power Supply24 V LED3 LED2 3. Antenna 2. Antenna Second GPC 4. Antenna (Type B) Optional Fig. 13: Connecting the components for a gate consisting of two antennas, reader and multiplexer FEIG ELECTRONIC GmbH Seite 26 von 69 M00910-8e-ID-B-ANATEL.doc...
Page 27
OBID i-scan Installation LRM2500 Fig. 14: Terminal board An overview of the terminal board assignment is given in 0. Annex A Note: • A reverse polarity could damage the device or the In-/Outputs. FEIG ELECTRONIC GmbH Seite 27 von 69 M00910-8e-ID-B-ANATEL.doc...
Page 28
X14 LED3 of the terminal board in Antenna Type A und X14 LED 3 at the 2. Antenna Type B must be installed. Grey wire (+ ) and green wire (-/GND). 1. People Counter and LED-light LED-light LED-light ANT1800700-A ANT1800700-B ANT1800700-B n.c. FEIG ELECTRONIC GmbH Seite 28 von 69 M00910-8e-ID-B-ANATEL.doc...
Page 29
A should preferably be connected shortly. Unused cable lengths are possible should be tied in antenna B type. Fig. 15:Connection of the components in an antenna Type A Fig. 16: Unused coaxial cables are tied in antenna Type B FEIG ELECTRONIC GmbH Seite 29 von 69 M00910-8e-ID-B-ANATEL.doc...
Setting the Multiplexer The jumpers JP11-JP14 should be set (factory setting) as shown. More on setting the ID ISC.ANT.MUX.M4 Multiplexer can be found in the corresponding installation manual (M90700-xde-ID-B). Fig. 17: Jumper positions FEIG ELECTRONIC GmbH Seite 30 von 69 M00910-8e-ID-B-ANATEL.doc...
Antenna switch closed Capacitor C1 JP 11,12,13,14 open Capacitor C2 JP21,22,23,24 open 25,26 Verify these settings. More on setting the ID ISC.DAT antenna tuner can be found in the corresponding installation manual (M40401-xde-ID-B). FEIG ELECTRONIC GmbH Seite 31 von 69 M00910-8e-ID-B-ANATEL.doc...
Fig. 19: Wiring example for connecting the RS232 interface Note: If there is an USB/RS232 converter used on the PC/Notebook side, we recommend to in- crease the „Char Timeout Multiplier“ parameter in the COM-Port settings from „1“ to about „5“. FEIG ELECTRONIC GmbH Seite 32 von 69 M00910-8e-ID-B-ANATEL.doc...
Table 9 Standard factory configuration of the Ethernet connection Note: The Reader TCP/IP interface has a DHCP option. More Information about the interfaces you will find in the manual M01111-xde-ID-B of the reader. FEIG ELECTRONIC GmbH Seite 33 von 69 M00910-8e-ID-B-ANATEL.doc...
Select „Run without change “ Note: This has to be done at each start of ISO-Start program otherwise the configuration of the reader will be changed by the wizard. Select „Options => Program“ FEIG ELECTRONIC GmbH Seite 34 von 69 M00910-8e-ID-B-ANATEL.doc...
Page 35
® OBID i-scan Installation LRM2500 Step Action Note Select „Expert Mode“ and confirm with OK. Select “Logical View” FEIG ELECTRONIC GmbH Seite 35 von 69 M00910-8e-ID-B-ANATEL.doc...
Page 36
0. Configure the reader in accordance with national RF regulations Set by clicking on „Apply“. Operating Mode: For antenna tuning the reader has to be set to „Host Mode“. Set by clicking on „Apply“. FEIG ELECTRONIC GmbH Seite 36 von 69 M00910-8e-ID-B-ANATEL.doc...
After successful tuning both antennas are shown in green. If this does not succeed on the first try, start the process again by clicking on „Start Tuning“ After successful tuning, close the DATuningTool. FEIG ELECTRONIC GmbH Seite 37 von 69 M00910-8e-ID-B-ANATEL.doc...
„Output Channel of Input 1 = 1“ Confirm with “Send” Activate “Test and Measurement” Select „Noise Level“ and start by clicking on „Start“ Normal Noise Level values: Average: < 20mV Difference (Max-Min): < 20mV FEIG ELECTRONIC GmbH Seite 38 von 69 M00910-8e-ID-B-ANATEL.doc...
Page 39
Are there devices nearby which may emit noise interferences (larger machines or wireless devices)? • Are there interferences from the mains? To determine which devices may be disturbing the gate, briefly disconnect them from the mains. FEIG ELECTRONIC GmbH Seite 39 von 69 M00910-8e-ID-B-ANATEL.doc...
Measurement“ Select „ISO Inventory“ function and activate by clicking on „Start“. The serial number and tag type will be shown in the display. Repeat Step 1 to 5 for every further antenna FEIG ELECTRONIC GmbH Seite 40 von 69 M00910-8e-ID-B-ANATEL.doc...
Here again the tag should always be read. The tag should be read within the gate by moving in a horizontal line through the gate in all three read orientations. FEIG ELECTRONIC GmbH Seite 41 von 69 M00910-8e-ID-B-ANATEL.doc...
Page 42
Transponder too insensitive, detuned or defective • Reader improperly configured (transmitting power, transponder type, modulation, transponder parameters, etc.). • A cable is defect or has a weak contact. • Reader, multiplexer or antenna defect. FEIG ELECTRONIC GmbH Seite 42 von 69 M00910-8e-ID-B-ANATEL.doc...
People Counter. The pulse duration can be set (CFG2 / OUT2) between 100 ms and 65535 s by adjusting the Reader configuration. The volume of the buzzer could be adjusted by R1 Fig. 21 Volume adjusting FEIG ELECTRONIC GmbH Seite 43 von 69 M00910-8e-ID-B-ANATEL.doc...
Set by clicking on „Apply“. Ext. IO: Enable People Counter by setting to “True” Set Detect Mode to “Search up to Busaddress 1” Set by clicking on „Apply“. FEIG ELECTRONIC GmbH Seite 44 von 69 M00910-8e-ID-B-ANATEL.doc...
Page 45
Up to four different AFI values could be set. Operating Mode If the alarm should occur by an EAS, you have to configure the reader as follow: Set “EAS” Set by clicking on „Apply“ FEIG ELECTRONIC GmbH Seite 45 von 69 M00910-8e-ID-B-ANATEL.doc...
Transponder Select „[0x27] Write AFI“ ADR: 1: addressed Serial Number: Select Transponder UID AFI: Desired AFI Number (not equal to 00) Write AFI byte on to the transponder by click on „Send“ FEIG ELECTRONIC GmbH Seite 46 von 69 M00910-8e-ID-B-ANATEL.doc...
The configuration of the Notification or Scan Mode are similar (See System Manual of the reader) To test the function of the Gate in the Buffered Read Mode, the BRM Window of ISOStart or the BRMDemo program can be used. FEIG ELECTRONIC GmbH Seite 47 von 69 M00910-8e-ID-B-ANATEL.doc...
Note Attention !! Note: Do not touch the an- tenna surface of the Radar module to avoid damaging the electronic components and soiling. Connect radar connection cable with X1 of Radar module. FEIG ELECTRONIC GmbH Seite 48 von 69 M00910-8e-ID-B-ANATEL.doc...
Page 49
See also picture in Step 4 Plug Radar connection cable onto X12 Sen 2 Radar Module Radar Module ID ISC.ANT.GPC-E ID ISC.ANT1800/700-GPC Gate People Counter ID ISC.ANT1800/700-GPC Fig. 22: Connections GPC-E 2.Radarmodule FEIG ELECTRONIC GmbH Seite 49 von 69 M00910-8e-ID-B-ANATEL.doc...
Fig. 24. At one reader, up to 3 People Counter (bus address 1-3) could be operated. Fig. 24: Position of Dip Switch at People Counter Board DIP-Switch S1 bus address OFF/ON Reserved Table 10 Setting the bus address of the People Counter FEIG ELECTRONIC GmbH Seite 50 von 69 M00910-8e-ID-B-ANATEL.doc...
0.Annex A e.g. 1.People Counter 2. People Counter 3. People Counter in antenna A in antenna Type B in antenna Type B (2.Antenna) (4.Antenna) (6. Antenna) Fig. 25 Connecting the People Counters FEIG ELECTRONIC GmbH Seite 51 von 69 M00910-8e-ID-B-ANATEL.doc...
Output 2 to antenna 2. Output 3 to antenna 3. „True“ means: Output 1,2 or 3 will be active if the reader read a valid trans- ponder on the correspond- ing antenna FEIG ELECTRONIC GmbH Seite 52 von 69 M00910-8e-ID-B-ANATEL.doc...
Page 53
Confirm with „Send“ Number of Devices should be 1 Select Command „Set People Counter Values“ Confirm with „Send“ Select Command „Get People Counter Values“ Confirm with „Send“ (All counter values should be 0) FEIG ELECTRONIC GmbH Seite 53 von 69 M00910-8e-ID-B-ANATEL.doc...
Page 54
In ISO-Host and Buffered Read the People Counter has to be polled by the Host Application to get the data. In Notification Mode the Reader sends the People Counter Data automatically to the Host. FEIG ELECTRONIC GmbH Seite 54 von 69 M00910-8e-ID-B-ANATEL.doc...
IP Address of Host e.g. here: 192.168.3.21 Port:10005 The same TCP/IP Address and Port Address is valid for the Notification Chanel of the People Counter und Notification Chanel of the data Confirm with „Apply“ FEIG ELECTRONIC GmbH Seite 55 von 69 M00910-8e-ID-B-ANATEL.doc...
Page 56
® OBID i-scan Installation LRM2500 A Test could be done with the People Counter Sample. Therefore you will have to set both ports have the same address, at the TCP- Settings. FEIG ELECTRONIC GmbH Seite 56 von 69 M00910-8e-ID-B-ANATEL.doc...
Otherwise the reading of the transponder will just be started, when the person/transponder is already in or outside the gate. Valid Transponder Exit of Building Long Range Reader ID ISC.LRM2500 X2 IN2+/IN2- FEIG ELECTRONIC GmbH Seite 57 von 69 M00910-8e-ID-B-ANATEL.doc...
Page 58
20x100ms =2sec. Confirm with „Apply“ Multiplexer stops switching of antennas. All Output LED´s at Outputs of Multiplexer are switched off. Walk through the gate. Multiplexer/Gate will be switch on for the set time. FEIG ELECTRONIC GmbH Seite 58 von 69 M00910-8e-ID-B-ANATEL.doc...
Maximum transmitting power per antenna • Permissible overall transmitting power per antenna gate 8.0 W – EU-territory (per EN 300 330) 8.0 W – USA (per. FCC Part 15) 8.0 W - Canada (per. RSS210) FEIG ELECTRONIC GmbH Seite 59 von 69 M00910-8e-ID-B-ANATEL.doc...
Page 60
110 / 120 cm*** – All tag orientations • Antenna connection 1 x SMA plug (50 Ω) • Antenna connector cable RG58, 50 Ω, approx. 8,55 m long - Type B FEIG ELECTRONIC GmbH Seite 60 von 69 M00910-8e-ID-B-ANATEL.doc...
Page 61
8 W, aligned in all 3 dimensions for horizontal movement through the antenna. The maximum antenna distance also depending of the strength of the Transponder answer signal! Z.B NXP I-Code SLi / NXP I-Code SLi-S FEIG ELECTRONIC GmbH Seite 61 von 69 M00910-8e-ID-B-ANATEL.doc...
• max. 2 VA • Operating Frequency • 24,125 GHz • RF-transmitting power • 16 dBm (e.i.r.p.) • Temperature range – Operation –25 °C to +55 °C – Storage –25 °C to +85 °C FEIG ELECTRONIC GmbH Seite 62 von 69 M00910-8e-ID-B-ANATEL.doc...
This RF equipment is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC dated March 99. Equipment Classification according to ETSI EN 300 330 and ETSI EN 301 489: Class 2 FEIG ELECTRONIC GmbH Seite 63 von 69 M00910-8e-ID-B-ANATEL.doc...
Further information and technical data of the LRM2500 Reader built into the ID ISC.ANT1800/700 antenna can be found in the Installation Manual which is included with the device. FEIG ELECTRONIC GmbH Seite 64 von 69 M00910-8e-ID-B-ANATEL.doc...
: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonc- tionnement. FEIG ELECTRONIC GmbH Seite 65 von 69 M00910-8e-ID-B-ANATEL.doc...
® OBID i-scan Installation LRM2500 USA and Canada (UL) The following picture indicates the label position: FEIG ELECTRONIC GmbH Seite 66 von 69 M00910-8e-ID-B-ANATEL.doc...
Connection LED / Alarm light antenna X14 / Pin 1 +24V DC LEDB X14 / Pin 2 GND LEDB 24V DC Power Supply X11 / Pin 1 Power Supply +24 V DC FEIG ELECTRONIC GmbH Seite 67 von 69 M00910-8e-ID-B-ANATEL.doc...