1. SAFETY RULES FOR FLUSH BOLT FIXTURE
A Use ONLY 1/2" diameter shank router bit
Using a smaller size shank could result in injury to operator due to the length
of shank which must protrude outside the router collet
B Always begin routing with router base firmly against fixture
and router guide and bit outside of fixture slot.
C Do not attempt to insert router bit down through fixture slot to begin routing
This will greatly increase the risk of injury to the operator and also increase the
potential of permanent damage to the top plate of the flushbolt fixture.
D Do not lift router base from flush bolt fixture.
Until after router bit rotation has stopped and router guide and bit are fully retracted
outside of fixture slot
E Avoid cutting materials with nails or knots
Inspect for and remove all nails. Cutting through knots or glued material may com
promise finished product.
2. SUPPLEMENTAL EQUIPMENT AND DATA
A. Use of flushbolt fixture requires:
1-1/2 HP Router
POR690 or equivalent
3/4" Diameter 1/2" shank router bit
WHII1085 or equivalent
Fixture template guide and nut
POR42030 Guide or equivalent
POR42237 Lock-Nut or equivalent
3. ADJUSTMENT
A. Router bit must protrude approximately 1-3/8" from router base
B. A length adjustment screw is provided to accommodate differences in hardware lengths
It is located at the end of the fixture. (Fig 1)
C. Centering the fixture on a door.
Is accomplished by adjusting the knobs on the side of the fixture that contain the jamb nuts. The two knobs
adjusted "OUT" all the way adjusts the fixture for a 1-3/4" door. Adjusting the knobs in "IN" all the way adjusts the
fixture for 1-3/8" door. To install or remove fixture after initial centering, You need only tighten or loosen the clamp
knobs on one side of the fixture.
FLUSH BOLT FIXTURE - MFG7500
OPERATIONAL INSTRUCTIONS
Fig. 1
Lock Nut
Length Adjustment
Screw

Advertisement

loading

Summary of Contents for Norfield MFG7500

  • Page 1 FLUSH BOLT FIXTURE - MFG7500 OPERATIONAL INSTRUCTIONS 1. SAFETY RULES FOR FLUSH BOLT FIXTURE A Use ONLY 1/2” diameter shank router bit Using a smaller size shank could result in injury to operator due to the length of shank which must protrude outside the router collet B Always begin routing with router base firmly against fixture and router guide and bit outside of fixture slot.
  • Page 2 4. OPERATION Slide the fixture over the door / T-astragal from the door end. Center the fixture (refer to 3 C above) and clamp it firmly to the door. While tightening clamps, be sure the fixture stays square to the door face. Begin routing with the router base firmly against the top of the fixture and the router guide and bit outside of.
  • Page 3 If you have any questions about additional applications or uses, DO NOT attempt those uses or modifications until you have been ad- vised by a qualified Norfield Representative. Any and all modifications to or misuses of the tool will void all warranties.