00. CONTENT 01. SAFETY INSTRUCTIONS INDEX ATTENTION: 01. SAFETY INSTRUCTIONS This product is certified in accordance with European Community (EC) safety standards. 02. CONNECTION SCHEMES COMPONENTS CONNECTION This product complies with Directive 2011/65/EU of the RADARS AND PROGRAM SELECTOR CONNECTION European Parliament and of the Council, of 8 June 2011, on CONNECTION OF 2 SINGULAR DOORS WITH INTERLOCK the restriction of the use of certain hazardous substances...
Page 3
01. AVISOS DE SEGURANÇA 01. AVISOS DE SEGURANÇA 01. SAFETY INSTRUCTIONS GENERAL WARNINGS the motorized door or gate from being triggered involuntarily. • This manual contains very important safety and usage information. WARNINGS FOR TECHNICIANS very important. Read all instructions carefully before beginning the installation/usage procedures and keep this manual in a safe place •...
Page 4
01. SAFETY INSTRUCTIONS to the release mechanism. use or maintenance! • Disconnect means, such as a switch or circuit breaker on the electrical • Safety norms are not followed in the installation, use and panel, must be provided on the product’s fixed power supply leads in maintenance of the product.
02. CONNECTION SCHEMES COMPONENTS CONNECTION Magnetic lock Control board +24V 12-24V AC/DC MDL1805 module 1º M1601 Radar Battery 24V Electric lock Automatism Radar 12-24V AC/DC 2º M1601 Radar RAP5M-PRO The electro lock current can not exceed 600mA. All connections should be made with the power supply disconnected.
02. CONNECTION SCHEMES RADARS AND PROGRAM SELECTOR CONNECTION Control board black brown yellow white white green green EXTERNAL purple Radar M1601 orange PROGRAM SELECTOR brown yellow white green Control board INTERNAL Radar M1601...
02. CONNECTION SCHEMES CONNECTION OF 2 SINGULAR DOORS WITH INTERLOCK 1st door is closed Control board of the 1st door 2nd door started opening Control board of the 2nd door Operation: When using 2 singular doors with interlocking, connected to each other, All connections should be made with the power off.
02. CONNECTION SCHEMES DOOR WITH 2 LEAVES Operation: When using a door with two leaves, you should note these connections. This function will allow the two sheets work in a coordinated manner. Control board 1 Control board 2 When using a kit of two sheets: 1 - LED 2 of both switches must be ON 2 - When the door input is set to leaf 1, LED 1 must be ON and LED 1 of the opposite panel must be OFF.
02. CONNECTION SCHEMES CONNECTION OF PUSH LOCK WITH MDL1805 MODULE IN-LOC OU-LOC GND 24+ OUT 12+ 24V+ Operation: Whenever an impulse lock is used, the MDL1805 module must be placed. With this module, whenever the automation receives an opening order, a signal is sent to the electrolock for 300ms to unlock and allow opening.
03. THE AUTOMATION 03. THE AUTOMATION TECHNICAL CHARACTERISTICS TECHNICAL CHARACTERISTICS The M1805-X is an automation with anodized aluminum chassis, developed to use in pedestrian Motor doors up to 120kg. • The control board is microprocessor controlled and does self programming. Users only need to select the speeds and the pause time.
04. PRE-INSTALLATION INSTALLATION MEASURES | OPENING DIRECTION Exterior opening Interior opening Maximum opening angles for the several combinations of allowed dimensions: Maximum opening angles for the several combinations of allowed dimensions: INTERIOR OPENING EXTERIOR OPENING Quotas X Quotas Y Quotas X 109°...
05. INSTALLATION INSTALLATION PROCESS INTERIOR OPENING EXTERIOR OPENING • • Remove the front cover of the automation, with the help of Direct the motor body and apply the screws, tightening Apply the side covers to the guide. completely. two screwdrivers. (Only for INTERIOR OPENING) Position the fixing body on the wall and make the markings.
06. THE CONTROL BOARD 06. THE CONTROL BOARD TECHNICAL CHARACTERISTICS TECHNICAL CHARACTERISTICS 167mm 1 • +24V battery power input 2 • Magnetic lock or impulse lock module 3 • +12V auxiliary power supply 4 • GND 5 • +24V component power supply 6 •...
06. THE CONTROL BOARD DIGITAL DISPLAY AND FUNCTIONS Increase button Selection of the function Decrement button Test button (START) Opening speed (1 to 32) Deceleration distance on door opening (1 to 32) Door slowdown speed (1 to 32) Closing speed (1 to 32) Closing deceleration distance (1 to 32) Closed automation force (1 to 32) Pause time (1 to 20 - 20 corresponds to 10 seconds)
07. TROUBLESHOOTING INSTRUCTIONS FOR FINAL CONSUMERS / SPECIALIZED INSTALLERS Anomaly Procedure Behavior Procedure II Find source of the problem • Door/Motor • Make sure you have • Still not working • Consult a qualified 1 • Open the control board and fuses (switch);...