Express VCDD0901 Quick Start Manual

Advertisement

IN-LINE
VENTILATORS • 120V
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer at the
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the
service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhaust-
ing of gases through the flue (chimney) of fuel burning
equipment to prevent backdrafting. Follow the heating
equipment manufacturer's guideline and safety standards
such as those published by the National Fire Protection
Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE),
and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected
to a GFCI (Ground Fault Interrupter) - protected branch
circuit.
9. Never place a switch where it can be reached from a tub or
shower.
10. This unit must be grounded.
CAUTION
1. For general ventilation use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbal-
anced impellers, keep drywall spray, construction dust, etc.
off power unit.
3. Please read specification label on product for further
information and requirements.
TABLE OF CONTENTS
This manual is divided into sections as follows:
This section shows a common installation in new and
existing frame construction.
- Mounting (New Construction)
- Mounting (Existing Construction)
- Wiring
- Ducting (Straight-Through Blower Discharge)
- Wiring Plate Position
- Blower Discharge Positions
- Ducting (Right-Angle Blower Discharge)

"WARRANTY"

MODELS
VCDD090I • VCDD150I
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VCDD0901 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Express VCDD0901

  • Page 1 MODELS VCDD090I • VCDD150I Page 1 IN-LINE VENTILATORS • 120V READ AND SAVE THESE INSTRUCTIONS WARNING TABLE OF CONTENTS This manual is divided into sections as follows: TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: •...
  • Page 2 MODELS VCDD090I • VCDD150I Page 2 TYPICAL INSTALLATION TYPICAL INSTALLATION MOUNTING (New Frame Construction) WIRING 12” ROUND DUCT BLACK 8” X 12” TO (OUTLET) 12” ROUND BLACK TRANSITIONS EDGE OF HOUSING GROUND TO WIRING PLATE 12” ROUND DUCT (INTAKE) WIRING PLATE WHITE GRILLE NUT...
  • Page 3 MODELS VCDD090I • VCDD150I Page 3 MOUNTING OPTIONS DUCTING OPTIONS BLOWER DISCHARGE POSITIONS ¼-20 hex nuts secure mounting brackets to housing. Loosen and re-tighten or remove and replace nuts as necessary for DUCT DUCT MOVABLE Housing desired mounting bracket position. CONNECTOR PANEL CONNECTOR...
  • Page 4 MODELS VCDD090I • VCDD150I Page 4 SERVICE PARTS SERVICE PARTS KEY NO. PART NO. DESCRIPTION 97014853 Damper Flap 99150415 Screw, #8B x ¼ (16 req.)* 98009520 Duct Connector (2 req.) 97014784 Housing Assembly 97014728 Mounting Bracket (2 req.) 99150591 Mounting Screw (4 req.) 97006142 Wire Harness 99150471...

This manual is also suitable for:

Vcdd1501

Table of Contents