Advertisement

Quick Links

IMPORTANT:
This procedure must be carried out only by BK Ultrasound service personnel or their authorized
representatives. The procedure covers unpacking and set-up of the system including connecting to the
power outlet and a possible network connection.
All scanners leaving the factory are configured for mains voltage 100-240V 50/60Hz and English
language. The mains voltage does not have to be changed as the power supply accepts 100-240V
50/60Hz.
CONTENTS
1
Necessary Tools .......................................................................................................................1
2
Unpacking the System..............................................................................................................2
3
Check the fuses ........................................................................................................................3
4
Fasten the Transducer Holder Frames.....................................................................................4
5
Set-up Additional Transducer Holders (Optional - UA1371) ....................................................5
6
Set-up Side-mount basket (Optional - UA1379) ......................................................................7
7
Connectivity ..............................................................................................................................8
8
Setting Up Printer Start-up Kit (Optional - UA4104).................................................................9
9
Connect the power cord..........................................................................................................10
10
Turn On the Scanner ..............................................................................................................11
11
Electrical safety test and functional test..................................................................................11
12
Creating an User.....................................................................................................................12
13
Changing language (Optional)................................................................................................13
14
Connecting to Wi-Fi (Optional) ...............................................................................................14
15
Time and Date Settings ..........................................................................................................14
16
General information ................................................................................................................16
1

Necessary Tools

-
Small thin slotted screw driver (e.g. 2mm or 3/32 in).
-
Tools for electrical safety test.
-
Torx #10 and #20 for printer set up.
-
Torx #25 for transducer holder frame and additional transducer holders.
-
Checking Procedure available in user guide.
IG42955-03
Installation Procedure for bkSpecto
16-01724 rev 00
Installation Procedure for bkSpecto
PAGE
1/16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the bk ultrasound bkSpecto and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Analogic bk ultrasound bkSpecto

  • Page 1: Table Of Contents

    Installation Procedure for bkSpecto Installation Procedure for bkSpecto IMPORTANT: This procedure must be carried out only by BK Ultrasound service personnel or their authorized representatives. The procedure covers unpacking and set-up of the system including connecting to the power outlet and a possible network connection. All scanners leaving the factory are configured for mains voltage 100-240V 50/60Hz and English language.
  • Page 2: Unpacking The System

    Installation Procedure for bkSpecto Unpacking the System 1. Cut and remove the two black straps. 2. Remove the cardboard. 3. Cut and remove the black strap. 4. Remove the top support. 5. Remove the plastic bag from the monitor and keyboard. 6.
  • Page 3: Check The Fuses

    Installation Procedure for bkSpecto 10. Remove the scanner from the pallet. 11. Empty the box from step 6. 12. Unpack the transducer holder frames from the bags. Note: The transducer holder frame package contains: 3 transducer holders, 1 gel holder, 2 transducer holder frame trays, and four screws.
  • Page 4: Fasten The Transducer Holder Frames

    Installation Procedure for bkSpecto Fasten the Transducer Holder Frames The scanner comes with two transducer holder frames. One for the right side with two transducer holders and one for the left side with one transducer holder and one gel holder. The screws used are in the zipper bag. If the system has been bought with the optional transducer holder kit UA1371 first go to step 5 Set-up Additional Transducer Holders (Optional –...
  • Page 5: Set-Up Additional Transducer Holders (Optional - Ua1371)

    Installation Procedure for bkSpecto Set-up Additional Transducer Holders (Optional – UA1371) UA1371 contains two additional probe holders. 2 x Cup holder 2 x Elastomer holder 2 x Transducer Base 8 x M312 screws Figure 5-1: UA1371 parts Note: Be aware the transducer bases for left and right are not identical. 1.
  • Page 6 Installation Procedure for bkSpecto 5. Fasten the probe holder bases to the probe holder frame and stiffener using 3 x M5X12 screws torx #25. 6. Slide the green elastomer holder inside the white cup holder. 7. Fasten the three transduce holders to the transducer bases with 4 x M3X12 screws pr. Transducer torx #10 IG42955-03 16-01724 rev 00 6/16...
  • Page 7: Set-Up Side-Mount Basket (Optional - Ua1379)

    Installation Procedure for bkSpecto Set-up Side-mount basket (Optional – UA1379) 1. Remove the two screw covers using a thin screw driver. Scanner Overview Procedure Place the screw driver in the pocket, press upwards, and pull. The locking Screw covers with mechanism is casted the two pins.
  • Page 8: Connectivity

    Installation Procedure for bkSpecto Connectivity Touch Display The IO board on the engine behind the lid. USB 3.0 For Pro- duction LAN / research (DICOM) HDMI USB 3.0 Mic in USB 2.0 Audio out Below the Engine Standby power Switch Mains input and fuses Potential...
  • Page 9: Setting Up Printer Start-Up Kit (Optional - Ua4104)

    Installation Procedure for bkSpecto Setting Up Printer Start-up Kit (Optional – UA4104) The printer is placed below the touch display in a printer holder. 1. Remove 1 screw with a torx #20 and remove the lid. Scanner Overview Procedure Note: Remember to support the cover while removing the screw 2.
  • Page 10: Connect The Power Cord

    Installation Procedure for bkSpecto 6. Connect the two cables to the printer and gently slide the printer into the holder. 7. Finally fasten the printer to the using four screws. The printer is fastened from below with four screws to the printer holder. Connect the power cord Unscrew the screw and remove the power restraint bracket...
  • Page 11: Turn On The Scanner

    Installation Procedure for bkSpecto Turn On the Scanner 1. Switch on the standby power. Scanner overview Parts Standby power switch 2. Click on one of the power buttons. Power Button Location Engine Button Monitor Button 3. The scanner boots up and is ready to be used. Follow 12 Creating an User, 13 4.
  • Page 12: Creating An User

    Installation Procedure for bkSpecto Creating an User 1. Login as the default system administrator. 2. Select Settings in the top right corner. 3. Select the SECURITY button. 4. Choose Add User. 5. Submit the personal information and select Next. IG42955-03 16-01724 rev 00 12/16...
  • Page 13: Changing Language (Optional)

    Installation Procedure for bkSpecto 6. Submit a password and press Add Note: More user specific settings are available and described in the User Guide and/or Service Manual. Changing language (Optional) 1. Login as an administrator. 2. Select Settings in the top right corner. 3.
  • Page 14: Connecting To Wi-Fi (Optional)

    Installation Procedure for bkSpecto Connecting to Wi-Fi (Optional) 1. Login as an administrator. 2. Select Settings in the top right corner. 3. Select the STORE / NETWORK button and choose the WI-FI tab. 4. Select CONFIGURE Wi-Fi. 5. Select the relevant Wi-Fi in the dialog on the monitor and press Connect. Time and Date Settings 1.
  • Page 15 Installation Procedure for bkSpecto 5. Select Time to enter the current time in the input area and select Enter 6. Select the relevant Date Format. 7. Select Date to enter the current date in the input area and select Enter IG42955-03 16-01724 rev 00 15/16...
  • Page 16: General Information

    Installation Procedure for bkSpecto 8. Finish by UPDATE TIME / DATE. 9. Restart the system General information Parameter Value REF number 1300 Name bkSpecto Weight of product in packaging 89 kg Dimensions of packaging 60x84x140 cm Packaging materials Flamingo (5kg) Cardboard (5kg) Plastic pallet (4kg) Packaging Material...

Table of Contents