10 to 12 gallons of water. It should be noted that even during the backflush cycle, the filtration process continues uninterrupted. Recommended Applications Tekleen OBF water filters are ideal for filtering out silt, scale, sand, rust, dirt and organic material like algae, zebra muscles, and clams from virtually all types of water sources.
Design Features Among the many features of the OBF models is their avoidance of the danger of forcing contaminated water back into the system, which often happens with a sand media filter. These filters will deliver clean water or no water.
The solenoid should be mounted in a vertical and upright position to reduce the possibility of contamination by foreign material. For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
3. PRESSURE DIFFERENTL ADJUSTMENT - the triggering differential is pre-set for 7 psi. It can be changed to different setpoints (see your rinse controller manual). For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
Proceed as follows: Turn inlet water off. Relieve any pressure on downstream side of filter. Unbolt clamp and remove lid. Remove pre-strainer cap. Remove pre-strainer. For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
Partially close a mainline valve downstream of the filter to maintain 25 psi on filter gauges. This pressure will ensure valve closure and also supply back pressure necessary to clean the screen. For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
The controller pressure differential is set too close causing vibration to initiate a flush cycle. SOLUTION Increase pressure differential (see Page 2 for both electronic ant hydraulic controller). For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
Water flow in new block is causing an increased pressure drop through filter which exceeds the controller setting. SOLUTION Re-adjust controller for the highest flow rate. (See pages 2 and 3). For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
5 gal. water) for 15 minutes. Then spray the filter with a high pressure hose to remove the contaminant. After reinstalling the filter, perform another super flush. For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...