If battery acid comes in contact with skin, rinse immediately with
water, then wash thoroughly with soap and water. If redness, pain, or
irritation occurs, seek immediate medical attention.
Eyes:
If battery acid comes in contact with eyes, flush eyes immediately,
for a minimum of 15 minutes and seek immediate medical attention.
LCD liquid crystal display:
with your skin: Wash area off completely with plenty of water. Remove
contaminated clothing. If liquid crystal gets into your eye: Flush the
affected eye with clean water and then seek medical attention. If liquid
crystal is swallowed: Flush your mouth thoroughly with water. Drink large
quantities of water and induce vomiting. Then seek medical attention.
SAVE THESE
INSTRUCTIONS
INTRODUCTION
Congratulations on purchasing your new Black + Decker
Digital Power Station. Read this Instruction Manual and follow the
instructions carefully before using this unit.
OVERVIEW
Common Actions and Unit Responses
Press the LED Area
A beep will sound and the Area Light will
Light Power Button.
turn on. The backlight will turn on for 10
seconds (only). The LCD screen will continue
to display the Battery Status and Voltage
Indicator. The LED Area Light remains on until
switched off.
Press the Battery
A beep will sound and the backlit LCD screen
Status Button.
will display the Battery Status and Voltage
Indicator for 10 seconds before the unit
automatically turns off.
Press the AC/USB
A beep will sound and the backlit LCD screen
Power Button.
will display the Battery Status Icon and the
USB Icon; the Digital Display shows "AC",
indicating the AC Outlet and the USB charging
port are ready to use. The unit remains on
until the AC/USB Power Button is pressed
again to turn both off.
Press the Compressor
A beep will sound and the backlit LCD screen
Power Button.
will display the Battery Status and the
Compressor Icon and will alternately show
the flashing pre-set PSI value (that was last
set using the compressor pressure control
buttons) and the current pressure of the
item being inflated (which will light solid). If
no further actions are taken after 1 minute,
the unit will display the Battery Status and
Voltage Indicator for 10 seconds before
automatically turning off.
Whenever the
... a beep will sound and the backlit LCD
clamps are properly
screen will display the Battery Status Icon,
connected to a battery
Battery Voltage Indicator, the Clamp Icons,
(refer to the "Jump
and the "+" and "–" signs, as well as the
Starter" section) ...
flashing Jump Starter Icon. The unit remains
on until the clamps are disconnected from
the battery.
If the Jump Starter
... a two-second warning will sound every
Power Switch is
10 seconds. The backlit LCD screen will
rotated to the on
display the Battery Status Icon, Battery
position and the
Voltage Indicator, the Clamp Icons, and the
clamps are not
"+" and "–" signs. The Alarm Icon and the
connected to a battery
Jump Starter Icon will flash. The unit remains
(refer to the "Jump
on until the Jump Starter Power Switch is
Starter" section) ...
switched off and then displays the Battery
Status Icon and the voltage of digital display
for 10 seconds before automatic shut down.
If liquid crystal comes in contact
Professional
®
If the clamp
... the backlit LCD screen will display the
connections to the
Battery Status Icon, Battery Voltage Indicator,
battery's positive and
and the Clamp Icons. The Alarm Icon, the "+"
negative terminals are
and "–" signs and the Reverse Polarity Icons
reversed ...
will flash and the unit will sound continuously
until the clamps are disconnected from the
battery.
When the unit is
... the backlight will turn on for 10 seconds
charging or
(only). The LCD screen will continue to
recharging using the
display the Battery Status Icon and Battery
built-in 120 Volt AC
Voltage Indicator. The bars on the battery icon
Charger ...
will change from empty to solid (bottom to
top) repeatedly.
Note:
The unit will automatically power off once ALL the functions are turned off.

VIEWING BATTERY STATUS

To check the unit's battery charge level, press the Battery Status Button.
The Battery Icon will indicate the battery charge level as follows:
• If the battery charge level is at full capacity, four solid bars will display.
• If the battery is partially charged, two or three solid bars will display.
• If the battery is nearly empty, one solid bar will display. The unit should be
charged at this time.
• If the battery is completely empty, four blank bars will display. The unit
MUST be charged at this time or the unit's built-in low voltage protection
will activate. The empty Battery Status Icon will flash for a short period
of time before automatic shut down. The unit will not operate until the
battery is recharged.
CHARGING/RECHARGING
Lead-acid batteries require routine maintenance to ensure a full charge and
long battery life. All batteries lose energy from self- discharge over time
and more rapidly at higher temperatures. Therefore, batteries need periodic
charging to replace energy lost through self-discharge. When the unit is not
in frequent use, manufacturer recommends the battery should be recharged
at least every 30 days and after each use.
IMPORTANT: If you attempt to use the unit when the unit's battery charge
level is too low, the unit will automatically shut down. Recharge the unit
with all other functions turned off as soon as possible.
Notes:
This unit is delivered in a partially charged state – you must fully charge it before using it
for the first time. Initial AC charge should be for 40 hours.
Recharging battery after each use will prolong battery life; frequent heavy discharges
between recharges and/or overcharging will reduce battery life.
Make sure all other unit functions are turned off during recharging, as this can slow the
recharging process.
CAUTION –
RISK OF PROPERTY DAMAGE: Failure to keep the battery
charged will cause permanent damage and result in poor jump starting
performance.
IMPORTANT: If you know the unit is discharged, but the battery icon
displays four solid bars as if the unit is fully charged when connected to
a charging power source, this may be due to the internal battery having
high impedance. The manufacturer suggests leaving the unit charging for a
period of 40 hours using the built-in AC charger before use.
Charging/Recharging Using the Built-In 120 Volt AC
Charger and AC Extension Cord (not included)
1. Lift the protective cover of the built-in 120 volt AC charger located on
the lower left front of the unit (refer to the Features section to locate).
Connect an extension cord to the unit. Plug the other end of the cord
into a standard 120-volt AC wall outlet. When the unit is properly
connected to an AC power source, the LCD screen will display the
following (the screen will be backlit):
The bars on the battery icon represent the capacity level of the unit's
internal battery. After 10 seconds, the backlight will shut off.
The bars on the battery icon will change from empty to solid (bottom to
top) repeatedly to indicate the unit is charging.
2. Charge for approximately 40 hours or until the battery icon shows 4
solid bars.