Page 2
Important instruction: 1 This manual detailedly describes bucket elevator of each system structure, function and use and maintenance method. Before installation and use of the machine , customer should read the manual, and have a full understanding of the ministries and its structure and function ,then have operation and maintenance of the machine.
2.1 General Structure TDTG Series Bucket Elevator mainly consists of elevator head, elevator casing, bucket, bucket belt, elevator foot and drive. Elevator head, elevator tail and elevator casing flanges are connected with bolts and sealed with sealing gasket. Buckets are fixed to the bucket belt with special-purpose bucket bolts.
position and quantity shall be determined according to requirement) so as to make air pressure in two casings keep balanced and ensure that materials are fed to and discharged out of the buckets smoothly. There is access door in the maintenance casing for observation and replacement of buckets and bucket belt.
Page 6
3.2.3 Mounting of Drive Motor, reducer, coupling, drive bracket and guard have already been assembled before the delivery. To mount the drive to the elevator body, the detailed requirement of Assembling General Drawing should be followed and the drive should be fixed to drive platform or head housing.
Page 7
Table 4 Deviation of Perpendicularity and Curvature Elevating Height H(m) Measuring <7 >30 7-30 Position Deviation(mm) 3.2.9.4 See Figure 8 for mounting of tail pulley shaft and see Table 5 for requirement on deviation. Table 5 Installing Deviation of Tail Pulley Shaft Elevating Height H(m) <7 >30...
3.4.1.4 Check to see if fasteners become loose. 3.4.1.5 Check to see if gap between return retainer and bucket is proper. 3.4.1.6 Remove the reverse stopper and adjust the rotation direction of motor. Mount the reverse stopper after the rotation direction is correct. 3.4.1.7 Start the motor by touch and check to see if there is abnormal noise.
4.2 Operation 4.2.1 To use the machine, firstly start the follow-up equipment of the machine, then start the elevator, and then start the preceding equipment from back to front in turn, finally feed the materials. 4.2.2 The machine should be started without load. Materials cannot be fed until the running without load is normal.
exceeds technical (3)Remove the trouble of drive or electric control. performance of the machine. (3)Drive or electric control is in trouble and cause sudden stoppage. 6 MAINTENANCE 6.1 Buckets and bucket belts should be checked and repaired completely once every month.
8 WEARING PARTS Table 7 List of Easily-worn Parts Elevator Elevator Bucket Bucket Belt Model Remarks (width mm) Head Bearing Tail Bearing Model TDTG40/18 UCP210 F90509 18/14 TDTG40/23 UCP210 F90509 23/14 19/14 TDTG40/28 UCP211 F90509 28/14 TDTG50/18 SN518 F90511 18/14 TDTG50/23 SN518 F90511...