Hot tub performance specifications For your own safety and the safety of your device, please comply with the following instructions . Read the following instructions carefully and comply with them during the use of the hot tub to prevent damage and risk of an injury . Hot tub performance specifications Performance specifications nominal voltage:...
Preparation for the installation of the hot tub Preparation for the installation of the hot tub Check the hot tub first before the installation . Immediately contact the seller in case any of the parts are broken or missing .Make sure that all the components correspond to your order .
Preparation Installation of the hot tub accordingtotheseconditions.The hot tub should be accessible from all sides for future repair services .Ifitisnotsufficientlyaccessibleduringtheguaranteeperiod, theownerhasadutytoensuretheaccess. 2 .3 Preparation for the exterior hot tub installation Ifthehottubisinstalledinanexteriorspace,itisnecessarytocomplywithsafetyin- structions.Thebasicsafetyrequirementsaremainlynon-skidfloorsandwaterdrain- ageincaseofarainfallorwateroverflowfromthehottub.Thereforewerecommend customizingtheplaceoftheinstallationaccordingtotheseconditions. 3 Installationofthehottub Warning: connection to electricity must be done according to norms valid in Czech Republic ČSN 33 2000-7-701 3 .
Installation of the hot tub/Audio system Aquatic 3 .2 Filling the hot tub with water Fillthehottubwithasufficientamountofwater.Thelevelofwaterinthehottub cannoteverfallundertheskimmerlevel.Ifyounoticeawaterleak,stopthewater untilthedefectisfixed.Hottubsdonotpossessthetechnologyforwater-softening andhardwatercanbedamagingtothem.Thedamagescausedbypoorhandlingand upkeeparenotcoveredbytheguarantee. a) F illthehottubthroughaskimmertopreventanoveraerationofthecirculation pumps. b) Donotfillthehottubwithwateroftemperatureover104°F. O ncethewaterreachesthedesiredlevel,putthecartridgefilterinsidethe skimmer.Tiltthefilterduringtheinstallationtopreventairbubbles.Onlyafter removingtheairfromthefilter,installthefilterintoplace. 3 .3 Running the power supply of the hot tub Ifthehottubisconnectedbyamovingsupplycable,thiscablecannotcomeincon- tactwithsharpobjectsorbeexposedtoexternalforces.Thereforewerecommend puttingthesupplycableinsideaprotectivecase.Turnonaresidualcurrentdevice...
Control panel Heating mode ready i n this mode the whirlpool heats the water to the set temperature economical in this mode the whirlpool only heats the water at the time of filtration Temperature range high 79 .88 –104 °F 50 – 98 .6 °F 5 .6 Blower Selectthenozzlebuttononthemainscreen.Pressblowerinthefollowingmenu....
Control panel press the setupbutton,thenpresstheright arrow.Inthismenu,youcanset,forexample, thetemperatureandtimeunits,thelanguage,orthecontrolpanelsleeptimer. Settings Settings Units Language Info Tools setting the temperature screenoff(timing)and units°Cor° Fandsettingthe error list timemodes12or24hours informations about the product,controlpaneland language settings control unit 5 . 1 1 Lock Theusercanindependentlylockthedisplayorallsettings.Lockingthesettingsrestricts control.Lockingallowstheuseofjetsandthesetfunctionsarestillactive.Tolock, selectthesettingsbuttononthemainscreen.PressLock.Thesettingoptions/panel aredisplayed.Touchtoselectwhethertolockthesettingsortheentirepanel.When youpresstheoption,thelocksettings/panelisdisplayedatthebottom.Pressthelock functiononthetopbarandholditfor5seconds.Thelockedoptionishighlightedwith atextlockbelowit.Tounlock,selectthelockedoptionandpressthelockbuttononthe topbaragain,holdfor5secondsandthefunctionwillunlock.
Control panel /Trouble shooting 5.12 Hold-on mode Theholdmodeisusedtodisconnectthepumpsduringservicing,suchascleaningor filterreplacement.Holdmodewilllastfor1hourunlesscanceledmanually.Ifittakes moretimetoservicethespa,itisbettertoturnoffthepowertothespa. 5 . 1 3 Information Thesysteminformationmenudisplaysvarioussettingsandidentificationofaparticular system.Sinceeachmenuitemishighlighted,thedetailofthisitemisdisplayedatthe bottomofthescreen.Youcanfinditinthesettingssection2underthetitleinfo. Settings Info Software ID (SSID) showsthesoftwareIDofthesystem system showsthesystemmodelnumber current settings displaysinformationforbuttonconfiguration(service) heating power input s howsoperatingel.thevoltagethatisconfigured heating type standardheating DIP switch setting shows the number that represents the positions of the fuselineS1onthemaindistributionboard display version...
Page 13
Trouble shooting Showupwhenconditionsofpossiblewaterfreezingaredetectedorthe conditions AUXfreezeswitchhasturnedoffwhilethecirculationpumpsandjetsare of possible turnedon.Insomecasesthecirculationpumpscanturnonandoffand freezing theheatercanruninthefreezeprotectionmode.Thisisaninformative operationalmessage,notadefectindicator. The water is too hot Oneofthetemperaturesensorsdetectedawatertemperatureof 109.94°Fandthehottubfunctionsaredisabled.Thesystemwill M029 automaticallyrestoncethewatertemperaturefallsunder107.96°F. Check whether the circulation pump has been running for too long or the surroundingtemperatureistoohigh. HEATER REPORTS The water flow through the heater is reduced Thisreportsaysthatnotenoughwaterflowsthroughtheheaterforthe M016 warmthfromtheheatertogeteffectivelydistributed.Theheaterwillturn onagainafterapproximately1minute.Seebelowfor“Checkingthewater flow”.
Page 14
Trouble shooting Checking the water flow Checkwhetherthewaterflowisnottoolow,whetherthereisanobstacleinthe areaofwatersuction,whetherthevalvesarenotclosed,checkforairpocketsand toomanyclosedjets.Somedevicescanoccasionallyturnonbythemselvestoenable temperaturemonitoringorrequestedfreezeprotection,evenwhenthehottubis turnedoff. SENSOR RELATED REPORTS The sensor balance is off M015 Thetemperaturesensorsynchronizationcanbeoffby60.98°Fupto 61.88°F.Calltherepairservice. The sensor balance is off M026 Thesensorsarenotsynchronized.Thereportisdisplayedlongerthan 1hour.Calltherepairservice. Sensor A failure, sensor B failure M031 (A) Temperaturesensororelectricalcircuitsensorhadfailed.Calltherepair M032 (B) service NON-CLASSIFIABLE REPORTS communication Thecontrolpaneldoesnotreceivereportsfromthesystem.Callthe failure repairservice.
Page 15
Trouble shooting Configuration failure (the hot tub will not turn on) hot tub will not turn on Contactyoursellerorrepairservices. The circulation pump appears stuck Thewatercanbetoohot.DISCONNECTTHEHOTTUBFROMTHE M034 POWERSUPPLY.DONOTENTERTHEHOTTUB.Contactyourselleror repairservices. Heating failure Thecirculationpumpappearedstuckduringthelasttimethehottubwas M035 turnedon.DISCONNECTTHEHOTTUBFROMTHEPOWERSUPPLY.DO NOTENTERTHEHOTTUB.Contactyoursellerorrepairservices. REMINDER MESSAGES General upkeep help RemindermessagescanbesuppressedinthePREF.menu.Reminder messagescanbeindividuallyselectedbytheproducer.Theycanbe general upkeep cancelledaltogetherorarestrictedamountofremindersisallowedfora specificmodel.Thefrequencyofeachreminder(forexample7days)can bespecifiedbytheproducerinadvance. Showsupregularly,forexampleonceevery7days.Checkthewater pH control pHlevelwithatestingkitandadjustthepHlevelbythesuitablewater chemicals.
Trouble shooting Upkeep of the hot tub treat the Showsupregularly,forexampleonceevery180days.Thecabinet wooden andwoodenequipmentofthehottubshouldbecleanedandtreated surface accordingtotheproducerinstructionstokeeptheirmaximumlongevity. Showsupregularly,forexampleonceevery365days.Thefiltersshould change the occasionallybereplacedtoensureaproperfunctionalityofthehottub filter andgoodhygiene. 7 Upkeepofthehottub 7 . 1 General information Donotexposethehottubtosunwithoutwaterinsideoracoverontop.Thedirect sunlightcancausefadinganddeformationofthesurfacematerial.Whenyouarenot usingthehottub,coveritwiththethermocover,regardlessofwhetheritisempty orfull.Protectthehottubfromrainandsnow.Placethehottubunderagazeboora roofifpossible. a) D onotopenthecontrolunit.Therearenouser-fixablepartsinside. b) D rain,cleanandfillthehottubwithcleanwateronregularschedule. Cleanthefiltercartridgeatleastonceaweek.
D ependingonthefrequencyofuseofthehottub,testthewaterqualityregular- lybyasuitablewaterqualitytester. A djustthewaterpHlevelaccordinglybysuitablewaterchemicals (theHANSCRAFT SPA – pH PLUS and pH MINUS isrecommended). d) A djusttheCl(chlorine)levelwithsuitablewaterchemicals(HANSCRAFT SPA – MULTI MINI 3 in 1 tabletsarerecommended).Followtheinstructionsonthe chemicals‘label. For the chlorine to have the desired effect, the pH level needs to be adjusted first .
Upkeep of the hot tub Ideal chemical levels 0.7–1.0mg/l Free chlorine concentration (10–15mg/l) (active oxygen concentration) pH level 7.0–7.6 Calcium 100–180mg/l Overall alkalinity 80–120mg/l 7 .4 Replacing the water Itisimportanttokeepthehottubwaterfreshandclean.Werecommendyouto replacethewateratleastevery3monthsunlessthewaterqualitydropssooner.The hottubwatercanbeusedforwateringthegardenforexample,giventhatithasnot beenchemicallytreatedatleastoneweekprior. a) Disconnectthehottubfromthepowersupply(turnofftheresidualcurrentdevice). b) Checkthepowersupplycableandmakesureitisnotwet. c) D rainthewaterthroughawaterdrainagesystem,closeitcarefullyandfillthe hottubwithfreshwater.
Upkeep of the hot tub Winter and summer time WARNING: For safety and damage prevention reasons, do not sit, stand or lie on top of the cover . Do not place any objects on top of it . The thermo cover does not serve as a fence around the bathing area either .
Winter and summer time/Final establishments Ifyoudecidetouseourprofessionalservices,itisnecessarytoorderthemsufficient amountoftimeinadvance.Incaseofwinterizingthehottubbyyourself,itiscrucial todoitwhentheairtemperatureisstillabovezero.Ifthewinterizingisdoneintem- peraturesbelowzero,itcanbeverydifficultbecausewaterinthemotorscouldhave frozenalreadyanddamagedsomepartsofthehottub. 8 . 1 Winter time – using the hot tub, all year operation (SLP) Ifyoudecidetokeepusingthehottubduringthewintertime,itisnecessarytokeep checkingthehottubforcasesofforexample:circuitbreakfailure,motornotwork- ing,heatingnotworking,filtercartridgegettingclogged. If the instructions above are not complied with and it results in a damage of the hot tub, the warranty cannot be claimed .
Repair services chart/Notes 10 Repairserviceschart A TABLE FOR YOUR NOTES, PLEASE FILL OUT THE FOLLOWING INFORMATION . You will need the filled out information in case of a repair requested through the customer service line . Purchase date Delivery date Model name Serial number Seller information...
Need help?
Do you have a question about the SPATOUCH and is the answer not in the manual?
Questions and answers