Bellcome Touch Line SCU.VDR03.BLG14 Technical Instructions

Bellcome Touch Line SCU.VDR03.BLG14 Technical Instructions

Supply and command central unit 4 wire video door system for buildings with 1-5 families
Hide thumbs Also See for Touch Line SCU.VDR03.BLG14:

Advertisement

Quick Links

SCU.VDR03.BLG14
SCU.VDR03.BLG34
TECHNICAL INSTRUCTIONS
Supply and command central unit
4 WIRE
video door system
for buildings with 1 – 5 Families
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Touch Line SCU.VDR03.BLG14 and is the answer not in the manual?

Questions and answers

Summary of Contents for Bellcome Touch Line SCU.VDR03.BLG14

  • Page 1 TECHNICAL INSTRUCTIONS Supply and command central unit 4 WIRE video door system for buildings with 1 – 5 Families SCU.VDR03.BLG14 SCU.VDR03.BLG34...
  • Page 2: Table Of Contents

    Contents 1. SAFETY INSTRUCTIONS for the Touch Line video door systems with 1-5 Families 2. Description of the supply and command central units (SCU) 3. Recommended cables for the Touch Line video door systems 4.1. Connections for the Touch Line video door systems with 1 Family 4.2.
  • Page 3: Safety Instructions For The Touch Line Video Door Systems With 1-5 Families

    SAFETY INSTRUCTIONS for the Touch Line video door systems with 1-5 Families 1. The Touch Line video door systems for 1, 2, 3, 4 or 5 Families DO NOT need authorized personnel to connect the SCU.VDR03.BLG14 or SCU.VDR03.BLG34 central unit to the power network. After completing the connections, you just have to plug the SCU central unit cable into the socket (230V/50Hz).
  • Page 4: Description Of The Supply And Command Central Units (Scu)

    Description of the supply and command central units (SCU) Dimensions: 130 x 141 x 73 mm Power supply voltage: 110/230Va.c. - 50/60Hz (from a grounded socket) Weight: 0.4 Kg Output voltage (+14): 13,5 - 14,0 Vd.c. max. 2.5Ad.c. Operating temperature range: 0 - 40 C Overload protection for the input and output current UL certified printed circuit board Case: PA6.6 + FS 10% (fireproof)
  • Page 5: Recommended Cables For The Touch Line Video Door Systems

    Recommended cables for the Touch Line video door systems 1. No authorized personnel is required for the installation and commissioning of the Touch Line video door systems for 1-5 Families (DIY)! 2. The supply and command central units will be installed inside the building. They can be mounted on a DIN rail (46277-3, EN50022, IEC60715) or directly on the wall and they will be connected to the 110/230Va.c.
  • Page 6: Connections For The Touch Line Video Door Systems With 1 Family

    Connections for the Touch Line video door systems with 1 Family Important! Central unit type SCU.VDR03.BLG14 Grounded socket Outdoor panel 110/230Va.c. - 50/60Hz max.12Ah/12V Vout LOCK DOOR LOCK VIDEO DOOR PANEL FUSE - T1.6A SUPPLY AC. 110/230V CAM switch 0 - without additional video camera 1 - with additional video camera AUX1 AUX2...
  • Page 7 4.2 EN Connections for the Touch Line video door systems with 2 or 3 Families Important! Grounded socket Central unit type SCU.VDR03.BLG34 Outdoor panel 110/230Va.c. - 50/60Hz max.12Ah/12V Vout LOCK DOOR LOCK VIDEO DOOR PANEL FUSE - T1.6A SUPPLY AC. 110/230V CAM switch 0 - without additional video camera 1 - with additional video camera...
  • Page 8: Connections For The Touch Line Video Door Systems With 2 Or 3 Families

    Connections for the Touch Line video door systems with 4 or 5 Families Important! Grounded socket Central unit type SCU.VDR03.BLG14 Outdoor panel 110/230Va.c. - 50/60Hz max.12Ah/12V Vout LOCK DOOR LOCK VIDEO DOOR PANEL FUSE - T1.6A SUPPLY AC. 110/230V CAM switch 0 - without additional video camera 1 - with additional video camera AUX1...
  • Page 9 Fam. 1 Fam. 2 Fam. 3 Fam. 4 Fam. 5 (address 1) (address 2) (address 3) (address 4) (address 5) DOORBELL DOORBELL DOORBELL DOORBELL DOORBELL GONG GONG GONG GONG GONG VCB.4DN03.BLG04 Note: The Fam. 1 terminal is programmed from the factory with address 1. The Fam.
  • Page 10: Connections For Separate Powered Ac Lock (Max. 3A)

    Connections for separate powered AC lock (max. 3A) IMPORTANT: A separate transformer ( 12/24V, max.3A) will be connected at the LOCK SUPPLY terminals. The AC lock 12/24V, max.3A, will be connected at the LCK1, LCK2 terminals. Valid for all types of Touch Line installations. Important! Grounded socket 110/230Va.c.
  • Page 11: Connections For Separate Powered Dc Lock (Max. 3A)

    Connections for separate powered DC lock (max. 3A) IMPORTANT: A separate DC power supply ( =12/24V, max.3A) will be connected at the LOCK SUPPLY terminals. The DC lock =12/24V, max.3A, will be connected at the LCK1, LCK2 terminals. Valid for all types of Touch Line installations. Important! Grounded socket 110/230Va.c.
  • Page 12 Connections for separate powered impulse control DC lock (max. 3A) Valid for all types of Touch Line installations. Important! Grounded socket 110/230Va.c. - 50/60Hz 12 24V, max. 3A 2 x 0,75 mm Lock 1 x 0,5 mm IMPULSE EXIT NC - Outdoor panel NO - 2 sec.
  • Page 13: Connections For Internal Powered Dc Lock In The +14/ Gnd Terminals Of The Scu (Max. 0.6A)

    Connections for internal powered DC lock in the +14/ GND terminals of the SCU (max. 0.6A) IMPORTANT: The LOCK SUPPLY terminals (+/- ) will be connected at the +14 and GND terminals of the VIDEO DOOR PANEL connector through 2 wires. The DC lock =12V, max. 0.6A, will be connected at the LCK1, LCK2 terminals. Valid for all types of Touch Line installations.
  • Page 14: Connection Of Auxiliary Installations

    Connection of auxiliary installations The additional installations (auto gate, garage door, outdoor lighting, etc.) will be connected at the AUX1, AUX2 terminals of the central unit and will be commanded from the keyboard of any Touch Line terminal. The AUX1, AUX2 contacts will close for 2 seconds and sustain a maximum current of 0.5A. Vin2 AUX 1 to the 1st additional installation...
  • Page 15: Programming The Touch Line Video Door Systems

    Programming the Touch Line video door systems Programming mode: long press (3 sec.) The PROG red LED turns on and of the PROG. button remains on during the entire programming phase. You can program: 1) The address of the terminal (housing number). The programming is done following the procedure in the audio-video terminals manual.
  • Page 16: Diagnosis And Service For The Touch Line Video Door Systems With 1-5 Families

    Diagnosis and service for the Touch Line video door systems with 1-5 Families 1. Normal functioning mode, connected to the network (110/230V), without BATTERY (BAT) connected in the SCU. 2. Normal functioning mode, connected to the network (110/230V), with BATTERY (BAT) connected in the SCU. Power failure mode, not connected to the network (110/230V), with BATTERY (BAT) (the system operates correctly until the BAT tension drops to 10V).
  • Page 17 10. If the SCU central unit fails, it will be replaced with a new one. In order not to reprogram already stored RFID cards, you will need to remove the EEPROM memory from the defective SCU central unit and insert it into the new SCU central unit, replacing the existing one. ATTENTION! When fixing the EEPROM memory, it is mandatory to keep the same position of the first pin!
  • Page 18: Declaration Of Conformity. Warranty

    Declaration of conformity. Warranty. The manufacturer ELECTRA s.r.l. declares that: The products are in compliance with the harmonised legislation of the European Union regarding the directives: Low Voltage (LVD) 2014/35; Electromagnetic compatibility (EMC) 2014/30/EC; RoHS 2011/65/EC. The following harmonised standards and technical specifications have been applied: SR EN 60950-1:2006 + A1:2011 + A2:2014 + A11:2009 + A12:2014 + AC:2011 + C91:2010;...
  • Page 20 BELLCOME is a trademark of ELECTRA Group - No. 013502646 - EUIPO - Alicante, Spain BELLCOME/ELECTRA products are registered as Industrial Models - EUIPO - Alicante, Spain The products are The products contain UL-compliant The products are manufactured under CE certified.

This manual is also suitable for:

Touch line scu.vdr03.blg34

Table of Contents