USING YOUR HUMIDIFIER (CONTINUED)
AUTO Mode: Your humidifier is equipped with both Auto and manual settings. When first powered ON, the
humidifier will start in Auto Mode. While in Auto Mode, the humidifier will automatically set the humidity output
level based on the ambient relative humidity in the room. When the humidity level is low, the humidifier will
add more moisture to the air at a faster rate. The target humidity level in Auto Mode is 60%. Once the humidity
reaches 60% in Auto Mode, the humidifier will stop producing mist while continuing to monitor the humidity level
around the device.
Humidity Output Level: To manually select an out put level, touch the Mist Control Icon.
Continue to touch
the icon to change the output level setting. The selection will cycle through Auto -> Low -> Medium -> High ->
Auto. The setting is indicated by the lit dot above the Mist Control Icon.
(See Control Panel section)
Humidity Level Setting: To set your preferred humidity level manually, select the Low, Medium or High output
setting, then use the Arrows
to set your desired humidity level. You can set the humidity level from 30%
to 69%. For personal comfort, the recommended humidity level is between 40-60%. When the desired humidity
level is reached, the Humidity Reached Icon
and Numeric Display are illuminated in blue. If the humidity level
in your space drops below 30%, the Display will show
Lo.
If the humidity level rises above 69%, the Display will
show HI.
Timer: To set the timer, press the Timer Icon.
h
Use the Arrows to increase or decrease the timer setting by
1 hour intervals, up to 12 hours. The timer is ON when the indicator above the Timer Icon is illuminated. To
turn the timer OFF, touch and hold the Timer Icon for 2 seconds, or use the Down Arrow to decrease the time
setting to
.
h
NOTE: Humidifier will continue to cycle on and off to maintain the set humidity level while the Timer is set. At the
end of the timed cycle, the humidifier will power off, regardless of the humidity setting. Any time the humidifier is
manually turned off (with the power button or by unplugging) the timer will reset to OFF setting.
Tank Light: To turn on the tank light, touch the Tank Light Icon.
Touch again to dim the light, and touch a
third time to turn off the light.
CONDENSATION: If you notice condensation on the walls, windows or around the humidifier, the humidity level is
too high. Open doors to the room or turn off humidifier until humidity level drops.
Mist Outlet
This humidifier features a directional Mist Outlet. Use this feature to direct the mist where you want it most. The
Outlet will rotate 90º in each direction from front to reduce white dust ingestion in the rear air input vent.