COMBUSTIBLE GAS LEAK DETECTOR USER MANUAL R00190 R00189 Before using the instrument, please read this manual carefully, and save for future reference.
Page 2
Information This product is NOT ATEX approved and is NOT suitable for use in hazardous areas in the oil, gas and petrochemical industries Safety Information. In order to use the gas leak detector correctly, please read the instructions carefully before use, noting any safety information.
Page 3
Information 3. Do not use the gas leak detector if it operates abnormally. 4. Do not use the gas leak detector on or near live apparatus. 5. Replace the batteries as soon as the power indicator flashes. This will reduce the possibility of false readings.
Page 4
Maintenance Maintenance Information. • The unit may be cleaned using a dry soft cloth, do not use a wet or abrasive cloth, solvents or detergents. • For extra protection always store the instrument in the case provided when not in use. Calibration.
Page 5
Features Accessories. • Storage pouch. • 3 x AAA alkaline batteries (included). • User instructions. Features. • Auto Zero: Automatically sets the sensor to zero at start up. • %LEL: Displays the percentage lower explosive limit (LEL). • PPM: Displays the amount of leakage in parts per million (PPM).
Page 7
Measurement Method Measurement Process. Push Buttons. Short Press: Turns the RAP300 on and off Short Press: Enter / Exit manual ZERO mode Long Press (>2s): Enter / Exit SET menu mode Short Press: To scroll select high, medium and low sensitivity Short Press: Activates data hold, press again to deactivate Short Press: Activates backlight,...
Page 8
Measurement Method Measurement Process. WARNING! Turn on the RAP300 in a “clean air” environment away from the test area. Failure to do so may cause the RAP300 to display error. 1) Turn the RAP300 on by pressing the key. The RAP300 will begin a 30 second countdown.
Page 9
Measurement Method NOTE - To prevent any false readings the product should only be used within its operational temperature range (See Page 12). Ensure the temeperature is within this range before use. Additional Features. Alarm Level Adjustment. Adjusting the alert sensitivity level can be set by the key.
Page 10
Measurement Method Auto Power Off. If there is no operation, If there is no detected concentration <10ppm then the unit will start the automatic shut down process, the unit will automatically shut down after 10 minutes. The auto power off feature can be enabled or disabled as required: 1) After the RAP300 has been turned on and has gone through the warm up period,...
Page 11
Measurement Method Vibration Function. 1) After the RAP300 has been turned on and has gone through the warm up period, long press the key to enter SET menu mode. Then short press the key one time to enter the vibration set menu. Press the key to change between vibration ON or OFF The following will be displayed:...
Page 12
Battery Replacement Battery Replacement. In order to avoid inaccurate readings, always replace the batteries when the appears on the top right of LCD screen. When the instrument is not in use for a long time, please take out the batteries to prevent damage caused by leakage.
Page 13
Specification Leak Detection Sensitivity 50ppm (Methane) Gases Detected Acetone, Acetylene, Alcohol, (Partial listing) Ammonia, Benzene, Butane, Ethanol, Ethylene Oxide, Gasoline, Hexane, Hydrogen, Methane, Naphtha, Natural Gas, Paint Thinners, Propane, Solvents Display Display with backlight, and bargraph Ranges Real PPM: 0 to 9999ppm; %LEL: 0 to 19.9% Accuracy +/-10%F.S.
Page 14
Limited warranty 1 year warranty against any manufacturing defects or faulty workmanship. This warranty does not cover fuses, disposable batteries or damage from accident, neglect, misuse, alteration, contamination or abnormal conditions of operation or handling. WEEE Directive 2012/19/EU At the end of the product life, dispose of the instrument &...