  • Page 1 ZPTX0010-P 30m³, ZPTX0018-P 50m³, ZPTX0030-P 90 m³...
  • Page 2 Introduction This manual contains all the necessary information for installation, troubleshooting and maintenance. Read the manual thoroughly before opening or using the unit. The manufacturer of this product will not be held responsible for injury to and/or damage of the product if it is the result of improper installation or unnecessary/incorrect maintenance.
  • Page 3: Technical Specifications

    50mm rubber Pool connection Optional (ZPHS0008) 50 x 95 cm Flow switch safety Beniferro ref ZWMX7010 Dimension plate (2x) Beniferro ref ZWMX7011 Technical Specifications Salinity 2-2.5 kg/m³ Salt The sodium chloride (NaCl) in the salt must be at least 99.6% and have a biocide approval number from the country in which it is used.
  • Page 4 Dosing pumps Present Flow switch ZWMX2155 Level detection acid and chlorine container Flow monitoring with notification on electrolyzer, no flow monitoring on acid addition. Power supply Optional Housing 230V ~, 50 Hz Installation IP65 IK07 Rohs Dimensions Wall mounting with screws and dowels Weight 50x95 cm Installation...
  • Page 5 ○ Install the water treatment unit on a solid base or against the wall (always vertical) ○ Always keep the product upright. If the product is tilted or laid on its side, the electrodes may not measure correctly. ○ The product must be installed inside. If you want to do it outside, please contact your supplier.
  • Page 6 3 Make a separate grounding for Your Salt Electrolysis with grounding pin. 4 Connect water inlet and water outlet so that water passes the Redox and pH measuring electrode first and then the salt electrolysis (or vice versa). Install the salt electrolysis in bypass configuration: The salt chlorinator should be installed with the return line to the pool and through the water treatment line as shown in the diagram.
  • Page 7 5 Connect the pH and redox measuring heads to the BNC connector at the positions provided: pH (left) RX (right) 6 Start the filter pump. 7 Check the installation for leaks. 8 Stop the filter pump. Remove the electrodes from the holder and calibrate pH and redox electrodes.
  • Page 8 Press the pH and Redox buttons (upper and lower button) for 10 seconds. Once the calibration starts a screen is activated and shows what YOU are calibrating, you can calibrate pH separately or calibrate Rx. A timer will stop after 120 seconds and give a message whether the calibration was successful.
  • Page 9 Reasons for a failed calibration: A bad calibration ( recalibrate) Calibration fluid is contaminated (replace fluid) recalibrate Measuring probe broken (left too long DRY) (replace probe) and recalibrate. Caution: broken pH probe pH value on screen =7 When the Ph and Rx are properly calibrated the screens will disappear automatically. After 2 minutes the screens disappear and you can read the values from the screen.
  • Page 10 If during operation you should find that the measured value of the dosing device does not really correspond to the value measured with a professional measuring device, you can enter the measured value here if the value is between 7 and 7.8 pH Via the back button you return to the main menu Pool.
  • Page 11 Press the lower button. The "dosage mode" setting is now checked. Press the middle button to activate this setting. You will now see that the dosing mode Prop (= proportional) or Cont (continuous) is selected. Press the middle button again. In the salt electrolysis dosing mode, you can choose between Salt Time or Salt Rx.
  • Page 12 When the setpoint Rx is reached the sequence will continue to run but no more chlorine will be created, chlorine will be created again when the measured Rx value has fallen below the setpoint Rx. The unit will measure Ph and Rx (redox) for 40 seconds. This measurement will be stored in the memory.
  • Page 13 With this dosing method, the chlorine content must be measured regularly using a color method. If the chlorine content is too low, the time must be extended. If the chlorine content is too high, the time must be reduced. 11.3) PH+ or PH- Press the lower button.
  • Page 14 As a rule the pH will be regulated at 7.4 The pH will be corrected with pH min. We recommend the use of 15% sulfuric acid, the weaker the sulfuric acid and the more accurately the pH dosage will work In the exceptional case that the pH drops below 7.2, it is best to bring it back to zone 7.2-7.6 by adding pH plus As an additional safety measure, we recommend that you do not lower the suction cup to...
  • Page 15 A color measurement with a reliable device (e.g. Poollab ZWMX1060), gives the best indication of the chlorine content in the pool. Free Chlorine ORP/mV vs pH 8,2 ppm 0,65 0,67 0,75 0,95 0,95 Example: your unit has the following values on the screen: pH 7,2 and redox of 740 then your pool water has a chlorine content of 1,2 ppm.
  • Page 16 ZPTX0010-P = unit 10gr/h , Pool for swimming pool 30 m3 ZPTX0018-P = unit 18gr/h , Pool for swimming pool 50 m3 ZPTX0030-P = appliance 30gr/h , Pool for swimming pool 90 m3 If you see that the redox is regularly far above the setpoint, you should reduce the intensity.
  • Page 17 If dosing is not interrupted for 240 min or 4 hours, the unit goes into alarm mode and stops the functionality of the dosing pumps and electrolysis. Alarm OFF: Never operate the unit in alarm OFF mode during normal and automatic operation. Alarm OFF mode is only used to monitor your unit in case of a malfunction.
  • Page 18 A flow switch can be added to the unit, for units that were produced in 2020 or later. On the circuit board with the display, there is the connection "FS" at the bottom left. These are connected to the two contacts of the flow switch. If no flow is detected, neither acid nor chlorine pump will run, and an alarm is generated.
  • Page 19 Chlorine Ideal business location Model production ZPTX0010-P 10g/h unit suitable for swimming pools = 30 m³ ZPTX0018-P 18g/h unit suitable for swimming pools = 50 m³ ZPTX0030-P 30 g/h unit suitable for swimming pools = 90 m³ Additional : operation and maintenance of the chlorinator 1.
  • Page 20 1.4 The correct way to add salt: A) Turn on the pool circulation pump and let the water circulation begin. B) Turn off the chlorinator. C) Test the current salt level of the pool. D) Calculate the amount of salt needed to add to the pool. E) Add salt to the pool around the side of the pool, allowing the salt to dilute quickly and evenly in the water.
  • Page 21 o Regularly check the tubing inside the peristaltic pump. Replace this hose immediately in case of leakage. It is advisable to replace this hose every 2 years as a precaution. o Regularly check the pH injection nipples for leaks. Replace these nipples immediately in case of leakage.
  • Page 22 Note: Extremely important: 1) Always turn off the power when you have the unit repaired or serviced. 2)When sending the unit for service, make sure the measuring probes are always in a storage liquid when sending. If the probes are left dry for 3 to 4 hours, this may affect subsequent measurements and result in erroneous readings.
  • Page 23 Winterize Attention! If you do not protect your product against the winter, it can cause damage and is no longer covered by warranty. In areas with high freezing temperatures, you should protect the pump, the filter and the dosing device from freezing. It is recommended to store the dosing devices inside in a dry and warm environment.
  • Page 24 Periodic maintenance Material Tasks Frequency Pool filter circuit Cleaning the filters Regularly Technical room Check that the nozzles are pointed slightly Regularly downward Electrical box Check all features listed in the precautions Regularly section Cell Check the metal parts for oxidation Regularly Check the tightness of the electrical connections As soon as water...
  • Page 25 Relay on the circuit board is stuck Contact supplier. Acid pump only doses occasionally Sour pump is set to proportional No action required dosing Chlorine pump does not dose Switch under the dosing pump is Set switch to "1 set to "O". Settings of Rx control are incorrect Verify settings A level detector is connected that...
  • Page 26 Unit goes into alarm: pH too high. pH > 8.5 Verify pH with color method. Correct pH manually or disable alarm function once and allow dosimeter to reduce pH. Acid container is empty Replace acid container Electrode broken Replace electrode Unit goes into alarm: pH too low pH <5.5 Verify pH with color method.
  • Page 27: Ec Declaration Of Confirmity

    EC Declaration of confirmity N° : 00ZW000 (front side) The undersigned, representing the following manufacturer Manufacturer: Zwembad BV Address : Balkenstraat 60 3071 Erps-Kwerps Belgium Herewith declares that the product Product identification Zwembad BV : ZWMX7521-P Is in conformity with the provisions of the following EC directive(s) (including all applicable amendments) Reference Nr Title...
  • Page 28 EC Declaration of confirmity N° : 00U000 (back side) References of standards and / or technical specifications applied for this declaration of conformity, or parts thereof : - harmonized standards: Number Issue Title EN60335-1 1994 EN60335-2-80 2003 EN 61000-6-3 10/2001 EMC Part 6-3: Generic standard.