Installation Requirements
Due to continuing product improvements, Heartland Appliances reserves the right to amend specifica-
tions without notice. Please contact Heartland for the most up to date information, as it applies to product
being purchased, or download latest Site Preparation Specifications from www.heartlandapp.com.
APPLIANCE REQUIREMENTS
Dimensions
36"
(92 cm)
14-1/4"
(36.2 cm)
standard
backguard
20" High
backguard
APPLIANCE REQUIREMENTS
Rough In
Measurements
55-3/4" (142 cm) min to
61-3/4" (157 cm) max
with std backguard
or
57-3/4" (147 cm) max
low profile backguard
Gas Outlet
Support desk must be
able to support 220 lbs
#02023
12-07-2006
Back of stove view
26-5/8"
(68 cm)
Air intake slots on
underside of control
panel must not be
obstructed
low profile
backguard
Range Hood Outlet
(6" clearance to any
combustible wall)
(33 cm)
13"
cabinet depth
6" (16 cm)
25"
6"x 6"
(63.5 cm)
(16 x 16 cm)
counter
cut out
depth
Electrical
service
Model 3820/3820B
Power
Cord
4"
(10.2 cm)
8-1/4"
(21 cm)
20" high backguard
Standard 6" high
backguard
Range Hood can only be vented from
above the hood as shown below (see Vent
Hood Specifications for full details)
1/8"
clearance
36
(page 2 of 2)
Standard backguard
Gas Inlet
1/2" NPT
2" (5.1 cm)
36"
(91.4 cm)
with 5" shelf
6"
(15.3 cm)
Low profile 2"
high backguard
26-5/8"
4-1/2" (11.5 cm)
(68 cm)
4" (10.2 cm)
Electrical
Gas outlet
Vent Hood
Min
30" (76.2 cm) to
Max 36" (92 cm)
with std backguard
or
Max 32" (81.3 cm)
with low profile backguard
© 2005 HEARTLAND APPLIANCES INC.
Help Desk
877-650-5775
6" (15.3 cm)
8-1/4" (21 cm)
2" (5.1 cm)
20" (51 cm)
2" (5.1 cm)
0"
clearance
to sides
18"
(46 cm)
36" (92 cm)