Attention - LG Therma V PHDPA Installation Manual

Drain pan

Advertisement

4. Attention

1. Four pipes (two refrigerant pipes and two
water pipes) should be fastened to the Drain
Pan (b) with ties.
2. The drain hose (field supply) should be
wrapped by thermal insulator (field supply)
with minimum 10 mm thickness.
- Be sure that there is no water leakage at the
connection of the drain hose.
- Remove water in the drain pan and the
drain hose in cold season to avoid freezing.
3. Three insulators (Insulator (a), Insulator (b)
and Insulator (c) ) should be attached without
vacancy.
• When installing the drain pan, be careful the sharp edges of product.
• If water is not drained, check the drain hose and drain pan installation.
Tie
Tie
Tie
Installation Manual 7
Attention
Drain Hose
Insulator