Advertisement

Quick Links

IP Deskset 47816A-700/710 Manual

Table of Contents

1
Web Configuration Initial Setup ................................................................................................................1
2
Tab Directory ...............................................................................................................................................2
3
Calls ...............................................................................................................................................................3
4
Directory .......................................................................................................................................................4
5
Accounts .......................................................................................................................................................5
6
Audio .............................................................................................................................................................6
7
Network ........................................................................................................................................................7
8
System ..........................................................................................................................................................8
9
Management ...............................................................................................................................................9
10 IP Deskset Controls ....................................................................................................................................10

Web Configuration Initial Setup

1.1 After unboxing the contents plug the AC adapter into a 110VAC outlet.
1.2 Connect the AC adapter to the receptacle on the rear of the chassis.
1.3 Connect an Ethernet cable (not provided) from the receptacle on the rear of the chassis to either a
network switch or directly into the NIC port of a computer.
1.4 The computer that is being used to program must be on the same subnet as the IP Deskset. To
change a computers network settings will vary depending on the version of the OS. Below are links
for both Microsoft and Apple computers to assist in changing network settings. The IP Deskset
comes from the factory with the address of 10.1.1.253 and a subnet of 255.255.255.0.
1.5 Open a browser and type 10.1.1.253 in the navigation bar and the authentication screen should pop
up.
1.6 The default credentials for the user name is admin and, the password is also admin.
https://support.microsoft.com/en-us/help/15089/windows-change-tcp-ip-settings
https://support.apple.com/kb/PH21579?locale=en_US
V A.1.0
1 |
P a g e

Advertisement

Table of Contents
loading

Summary of Contents for Raven 47816A-700

  • Page 1: Table Of Contents

    IP Deskset 47816A-700/710 Manual V A.1.0 Table of Contents Web Configuration Initial Setup ………………………………………………………………………………………………….1 Tab Directory ……………………………………………………………………………………………………………………………..2 Calls ……………………………………………………………………………………………………………………………………………3 Directory …………………………………………………………………………………………………………………………………….4 Accounts …………………………………………………………………………………………………………………………………….5 Audio ………………………………………………………………………………………………………………………………………….6 Network ……………………………………………………………………………………………………………………………………..7 System ……………………………………………………………………………………………………………………………………….8 Management ……………………………………………………………………………………………………………………………..9 10 IP Deskset Controls ……………………………………………………………………………………………………………………10 Web Configuration Initial Setup 1.1 After unboxing the contents plug the AC adapter into a 110VAC outlet.
  • Page 2: Tab Directory

    IP Deskset 47816A-700/710 Manual V A.1.0 Figure 1. Log in screen Tab Directory 2.1 Once log in has been achieved just below the navigation bars is the tab directory. The tab directory will be used to make changes to all settings within the IP Deskset.
  • Page 3: Calls

    IP Deskset 47816A-700/710 Manual V A.1.0 Calls 3.1 This tab is used to modify inbound or outbound call settings. 3.2 For outbound calls a default ringback tone has been preloaded in the unit and is set as a default. 3.3 The ringback tone can also be a custom tone that is uploaded to the unit.
  • Page 4: Directory

    IP Deskset 47816A-700/710 Manual V A.1.0 Directory 4.1 The SIP phone directory can be used for auto dialing other SIP units residing on the same network as the IP Deskset. 4.2 First a description of the device to be called must be entered.
  • Page 5: Accounts

    IP Deskset 47816A-700/710 Manual V A.1.0 Accounts 5.1 The accounts tab is used to connect the IP Deskset to a SIP PBX. Each IP Deskset is capable of being connected to multiple servers. Each account can be retained for future use. There is an option on the left-hand side of the screen to disable, register or, unregister each account.
  • Page 6: Audio

    IP Deskset 47816A-700/710 Manual V A.1.0 Audio 6.1 The Speaker volume can be set from 1-9. 1 would be the softest setting and 9 would be the loudest setting. 6.2 The Microphone can be set from 1-9. 1 would be the softest setting and 9 would be the loudest setting.
  • Page 7: Network

    IP Deskset 47816A-700/710 Manual V A.1.0 Network 7.1 Under the General section the Host Name can be inserted as well as the Domain. The unit can be set to either Dynamic or Static IP address. 7.2 If the unit is set to a Static IP address an IP address and Subnet will need to be assigned to it.
  • Page 8: System

    IP Deskset 47816A-700/710 Manual V A.1.0 System 8.1 The default Username and Password are admin and admin. Either of these settings can be changed here. 8.2 The IP Deskset logs can be sent to a Syslog Server. To send these logs check the Report to Server box and then enter the Server IP address and the desired Port number.
  • Page 9: Management

    9.4 Note that the firmware version is located here. This may need to be provided to Raven tech support in the case of an inquiry for assistance. 9.5 To update the firmware on the unit a newer version of firmware will need to be provided by Raven and saved to a local computer.
  • Page 10: Ip Deskset Controls

    IP Deskset 47816A-700/710 Manual V A.1.0 IP Deskset Controls 10.1 The IP Deskset comes with an AC adapter that plugs into the rear of the unit. 10.2 Also located on the rear of the unit is a network port. 10.3 The dash 700 model comes with a supplied Gooseneck style microphone that plugs into the XLR connector on the top of the unit.

This manual is also suitable for:

47816a-710

Table of Contents