Menred RT5 Manual

Menred RT5 Manual

Floor heating thermostat

Advertisement

Weekly programmable digital display
4 time periods/switch manual or time periods
mode by one button
RT5 Floor Heating Thermostat

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RT5 and is the answer not in the manual?

Questions and answers

Summary of Contents for Menred RT5

  • Page 1 Weekly programmable digital display 4 time periods/switch manual or time periods mode by one button RT5 Floor Heating Thermostat...
  • Page 2: Time Periods

    4 Time Periods One week cycle First time period: get up in the morning Second time period: Go out in the morning Third time period: Back home in the afternoon Fourth time period: Sleep time...
  • Page 3: Window Open Function

    Window open function When the thermostat detects the temperature drops Y℃ within X minutes, it will enter into window open mode and continue to work Z minutes. (The values of X, Y, Z can be set)
  • Page 4: Preheat Function

    Preheat function • Operate under time period mode • Turn on heating before reaching • the next time period • Reach the next set temperature • in advance...
  • Page 5 & Press buttons for 5S Lock or unlock...
  • Page 6 Weekly programmable/4 time periods available to set the required temperature 5G Frequency; Connect WIFI via Bluetooth Mobile phone APP remote control Able to upgrade online TuyaSmart...
  • Page 7 One button 5 seconds weekly programmable week and time Press the button for 5s Press the button for 5s Temperature control Adjust current week and with 4 time periods time Two buttons 5 seconds Advanced setting Wi-Fi connection Press two buttons Press two buttons &...
  • Page 8 Press and hold above buttons for 5s to enter Heating into WIFI connection Press and hold above Hold above buttons for 5 buttons for 5 seconds to seconds to lock or unlock enter into advanced setting Manual mode press the button for 5s Time period mode button to set the schedule...
  • Page 9: Selection Table

    Selection table Model Load Description RT51.13 Water floor heating Water floor heating + RT51.23i potential-free output + Wi-Fi Electric floor heating + floor RT51.36t sensor Electric floor heating +floor RT51.36i sensor + Wi-Fi...
  • Page 10: Technical Data

    Technical data Working voltage: AC220V 50Hz; Rated power: <1.5W Measured range:-9.5~99.5℃; Protection class:IP20 Signal terminal: 0.75mm lead Ambient temperature : -10~55℃ Wiring terminal: one terminal can be connected to 2*1.5mm2 or 1*2.5mm2 wire at most Wiring method...