Installation instructions for ac fan remote control (4 pages)
Summary of Contents for AIRBORNE Activ
Page 1
Activ Installation & User Manual PLEASE NOTE: THE FAN WILL ONLY OPERATE WITH THE WALL MCU CONTROLLER SUPPLIED SEE BACK PAGE ATTENTION ELECTRICIANS: ANY PROBLEMS FOUND DURING INSTALLATION OF THE FAN PLEASE CONTACT THE NATIONAL WARRANTY NUMBER PRIOR TO LEAVING SITE. DO NOT REMOVE THE FAN FROM THE CEILING UNLESS INSTRUCTED TO DO SO.
Page 2
IMPORTANT INFORMATION - PLEASE READ BEFORE ATTEMPTING INSTALLATION Please read these instructions carefully, be mindful of all warnings and safety information shown throughout this manual. Should you have any questions, please contact 1300 116 305. Please review the accompanying assembly diagrams before attempting installation. This fan MUST be installed by a licensed &...
LOCATION AND INSTALLATION REQUIREMENTS Provide adequate clearance from the floor. The lowest point on the Ceiling fan blades must be at least 2.1m (7 feet) from floor level in Australia and at least 2.3m from floor level in the European Union and affiliated countries.
FAN ASSEMBLY & PARTS LIST - WITHOUT LIGHT KIT Unpacking your Fan Unpack your fan and check the contents. Please check each item prior to installation, should you find any issues please contact the Warranty Helpline on 1300 116 305 for assistance. To reduce the chance of marks or possible damage please only remove the parts when required for installation.
FAN ASSEMBLY & PARTS LIST - WITH LED LIGHT KIT Unpacking your Fan Unpack your fan and check the contents. Please check each item prior to installation, should you find any issues please contact the Warranty Helpline on 1300 116 305 for assistance. To reduce the chance of marks or possible damage please only remove the parts when required for installation.
INSTALLING HANGER BRACKET - ENSURE CAN TAKE 25KG LOAD In accordance with Australian Standards, the fan blades must be at least 2.1 metres above floor level and the blades require at least 300mm clearance to the nearest object. Ensure only the supplied Hanger bracket screws are used Ensure ceiling joists are sound and of adequate size and strength to support a 25Kg (55lbs) load.
INSTALLING FAN In accordance with Australian Standards, the fan blades must be at least 2.1 metres above floor level and the blades require at least 300mm clearance to the nearest object. DANGER! Before commencing installation, turn off electricity supply at the main power box or disconnect power by removing fuse or turning off circuit breaker.
OPTIONAL ACCESSORY - EXTENSION ROD INSTALLATION In accordance with Australian Standards, the fan blades must be at least 2.1 metres above floor level and the blades require at least 300mm clearance to the nearest object. DANGER! Before commencing installation, turn off electricity supply at the main power box or disconnect power by removing fuse or turning off circuit breaker.
SUMMER AND WINTER MODE EXPLAINED FORWARD (Summer) Mode Ceiling fans are an environmentally smart choice to assist with cooling and warming your home. In FORWARD (Summer) mode your ceiling fan will spin to push air down the centre of the fan producing a cooling breeze.
CHANGE LED COLOUR TEMPERATURE WITH LIGHT VERSION DANGER! Before changing colour temperature on the light kit , turn off electricity supply to the fan at the isolation switch and wait for fan blades to stop rotating. The light kit on the fan has three different colour temperature options 3000K / 4000K / 6000K. The fan has a switch built into the light kit allowing the user to toggle between colour temperatures.
When humidity is high and temperature drops moisture condenses on metal surfaces including ceiling fans. The layer of moisture can be almost microscopic but it will affect the surface by depositing a tiny layer of dissolved salts or airborne acidic compounds and thus eventually leading to corrosion if the product is not properly and regularly cleaned. This applies equally to indoor and outdoor fans.
TROUBLESHOOTING PROBLEM POSSIBLE CAUSES PROBABLE SOLUTIONS Fan does not power Check the dwelling’s fuse/box circuit breakers has not No mains voltage going to fan. failed / tripped and check that 240V is available at the Terminal Block. Isolation switch turned off. Check isolation switch is turned on.
CEILING FAN WARRANTY INFORMATION This warranty applies only to Australian states and its mainland territories. The benefits of this warranty are in addition to any rights offered under state or territory law. Please also note the following, prior to requesting service, please consult the Troubleshooting section in the manual;...
ELECTRICIAN CHECKLIST Electricians make sure everything on this checklist is ticked off before you leave the installation site. If you have trouble installing our product please refer to the trouble shooting section on page 11 first, then phone the AeroDC Warranty Hotline on 1300 116 305 (open 9am to 5pm EST).
FAN WIRING DIAGRAM - MCU AND ISOLATION SWITCH An isolation switch providing full disconnection of both fan and light must be fitted in accordance with the wiring rules (AS/NZS 60335.1 C1.7.12.2). In addition to all pole disconnection an isolation switch must be installed for each individual fan located in the same room to allow for programming and ongoing maintenance.