Advertisement

Quick Links

AlphaFreshbox 200 WiFi
With and without Radon sensor
Manual
March 2021

Advertisement

Table of Contents
loading

Summary of Contents for RadonTec AlphaFreshbox 200 WiFi

  • Page 1 AlphaFreshbox 200 WiFi With and without Radon sensor Manual March 2021...
  • Page 2 RadonTec GmbH Hauptstraße 5 89426 Wittislingen - Germany Tel: (+49) 9076 - 919 98 35 E-Mail: info@radontec.de Website: radontec.de Shop: radonshop.com Version: 01...
  • Page 3: Table Of Contents

    Remote control ............... 30 Emergency stop .............. 51 Error codes/warnings ..........52 Troubleshooting ............53 Maintenance and servicing ........54 Transport and storage ..........57 Disposal ..............58 Two year warranty ............. 58 Support and Contact ..........62 Manual – AlphaFreshbox 200 WiFi...
  • Page 4: Introduction

    The installation and operation of the unit must be carried out in accordance with this user manual and with the provisions of all applicable local and national Manual – AlphaFreshbox 200 WiFi...
  • Page 5: Safety Precautions During Unit Installation

    The unit must be earthed! Do not operate the unit outside the temperature range specified in the user manual or in aggressive or explosive environments. Do not use damaged equipment or wiring to connect the unit to the mains. Manual – AlphaFreshbox 200 WiFi...
  • Page 6 Make sure that the impeller and the housing are not damaged before connecting the unit to the mains. The casing installations must be free of foreign bodies that could damage the impeller blades. Manual – AlphaFreshbox 200 WiFi...
  • Page 7: Safety Instructions For Operating The Unit

    Do not touch the controller or remote control with wet hands. Do not perform maintenance on the unit with wet hands. Do not wash the unit with water. Protect the electrical parts of the unit from water penetration. Manual – AlphaFreshbox 200 WiFi...
  • Page 8 Do not allow children to operate the unit. Do not damage the mains cable while the unit is in operation. Do not place any objects on the mains cable. Manual – AlphaFreshbox 200 WiFi...
  • Page 9 Make sure that the air flow of the unit is not directed towards appliances with an open flame or candles. The unit is not intended to be used by children, physically or mentally handicapped persons, persons with sensory disorders persons without appropriate qualifications. Manual – AlphaFreshbox 200 WiFi...
  • Page 10: Intended Use

    +1 °C to +40 °C and a relative humidity of max. 70 %. The dew point temperature of the conveyed air must be 2-3 °C below the temperature of the enclosure surface so that no condensate can form inside the enclosure. Manual – AlphaFreshbox 200 WiFi...
  • Page 11: Scope Of Delivery

    Scope of delivery Please check the completeness of the scope of delivery using the following parts list: 1x ventilation system 1x operating manual 1x Mounting template 1x Fastening set 1x Magnetic sheet 1x Key 1x spigot Manual – AlphaFreshbox 200 WiFi...
  • Page 12: Technical Data

    -15 to +40 °C temperature Painted steel Material of the casing 30 mm Insulation Efficiency of heat 75 % 70 % 68 % 67 % 66 % recovery Countercurrent heat exchanger Type of heat exchanger Manual – AlphaFreshbox 200 WiFi...
  • Page 13: Dimensions

    Heat exchanger Enthalpy membrane material G4 + F7 (H13 optional) Supply air filter Exhaust air filter Diameter of the Ø 100 mm connection spigot 44 kg Weight Dimensions Manual – AlphaFreshbox 200 WiFi...
  • Page 14: Design And Operating Logic

    In the heat exchanger, the heat from the warm extract air is transferred to the cold outside air. Here, the two air flows are completely separated from each other. Manual – AlphaFreshbox 200 WiFi...
  • Page 15 AlphaFreshbox 200 WiFi is equipped with a pre-heating coil. If the supply air temperature is below -3 °C, the pre-heating coil automatically heats the supply air so that the average temperature of the extract air downstream of the heat exchanger is not below +5 °C.
  • Page 16 The exhaust air grille must be closed with the magnetic plug included in the scope of delivery (see "Installation and preparation for operation"). Manual – AlphaFreshbox 200 WiFi...
  • Page 17: Assembly And Operation

    Assembly and operation Read these operating instructions carefully before installing the unit! Sufficient maintenance access must be considered when mounting the unit. The recommended minimum distances between the ventilation unit and the walls are as follows: Manual – AlphaFreshbox 200 WiFi...
  • Page 18: Mounting

    Lay all cables and pipes to the installation site before starting the installation work. 2. Remove the template and drill two core holes for the ventilation pipes with a diameter of 120 mm. Manual – AlphaFreshbox 200 WiFi...
  • Page 19 (A). For details, see the installation instructions for the ventilation bonnet. The external bonnet is not included in the scope of delivery of the ventilation system and is available as an optional accessory. Manual – AlphaFreshbox 200 WiFi...
  • Page 20 To install the ventilation system with a second room connection, place the connection elbow in the hole prepared for it in the wall and fix it with wedges. Connect the connection elbow to the air duct. Manual – AlphaFreshbox 200 WiFi...
  • Page 21 6. Inserting an additional exhaust vent: remove the plug at the back of the unit. To do this, unscrew the screws, remove the plug and fix the spigot in its place with the screws. Manual – AlphaFreshbox 200 WiFi...
  • Page 22 8. Remove the F7 and H13 filters to gain access to the mounting holes. 9. If an exhaust air spigot is fitted, remove the protective cover and fit the magnetic plug to the exhaust air grille. Manual – AlphaFreshbox 200 WiFi...
  • Page 23 Fasten the system with the screws supplied (included in the scope of delivery). The system is fixed with four screws. Reinsert the filters, the earthing cable and the protective covers into the ventilation system and close the access door of the system. Manual – AlphaFreshbox 200 WiFi...
  • Page 24 Remove the excess foam. Fill the cavities between the ventilation pipe and the wall with a sealant. Fix the outer bonnet to the outer wall of the building (see assembly instructions for the outer bonnet). Manual – AlphaFreshbox 200 WiFi...
  • Page 25: Mains Connection

    To select the tripping current, take the next value of the miniature circuit breaker in the series after the maximum current consumption of the unit. Manual – AlphaFreshbox 200 WiFi...
  • Page 26: Connecting Additional Control Units

    Remove the jumpers between the terminals 5 and 6. In case of fire, the normally closed dry contact breaks the control circuit from the central fire-fighting board and cuts off power supply to the unit. Manual – AlphaFreshbox 200 WiFi...
  • Page 27 Type of Conductor contact PK1* Contact of fire alarm N.C. 2 x 0,25 mm shield RH1* Contact of external N.O. 2 x 0,25 mm sensor * The unit is not included in the delivery set. Manual – AlphaFreshbox 200 WiFi...
  • Page 28: Control

    Control The ventilation system is controlled via the control panel on the housing of the ventilation system, via the remote control and via the app. Manual – AlphaFreshbox 200 WiFi...
  • Page 29 5 seconds, it starts flashing and the control unit switches to "Setup Mode". At the end of the filter life, the filter change indicator on the control panel lights up to indicate that the filters need to be replaced. Manual – AlphaFreshbox 200 WiFi...
  • Page 30: Remote Control

    The switch-off time of the fans is 0.5-2 minutes, depending on the model of the ventilation system. Remote control Control via app on mobile device For Android in the Google Play Store: https://play.google.com/store/apps/details?id=com.embarca dero.BlaubergFRESHBOX Manual – AlphaFreshbox 200 WiFi...
  • Page 31 Frequency band, GHz Transmission power, mW 100(+20) (dBm) Network DHCP WLAN security WPA, WPA2 If the app is started without connecting to the system, the following message is displayed on the screen of the mobile device: Manual – AlphaFreshbox 200 WiFi...
  • Page 32 - Call up the menu of the app - Select the menu item Connection - Home. If the mobile device is connected to WLAN access point without router, then select the default connection. In case of Manual – AlphaFreshbox 200 WiFi...
  • Page 33 - If necessary, change the connection name, enter the password of the system (valid characters: 0 ... 9, a...z, A...Z). The default password of the system is 1111 (four ones). - Confirm the entered data by pressing the key Manual – AlphaFreshbox 200 WiFi...
  • Page 34 - Go to the menu ( ) - Connection - Home. - Select the connection and press the key - Enter and confirm the password. Valid characters: 0...9, a...z, A...Z - Press the Change Password key. Manual – AlphaFreshbox 200 WiFi...
  • Page 35 In this mode, up to 8 mobile devices can be connected to the fan to control it. Select the desired security level for the Access point mode: Open: not password protected. WPA PSK: password protected. WPA2 PSK: password protected. WPA/WPA2 PSK: password protected (recommended). Manual – AlphaFreshbox 200 WiFi...
  • Page 36 DHCP: automatic assignment of the IP address when connecting to the home router (recommended). Static: allows the IP address, subnet mask and default gateway to be assigned manually. These settings are only recommended for experienced users. Manual – AlphaFreshbox 200 WiFi...
  • Page 37 To exit the setting mode immediately, press and hold the button again for 5 seconds until the LED stops flashing. The following parameters are available for connecting to the system in setup mode: WLAN name: Setup Mode. Manual – AlphaFreshbox 200 WiFi...
  • Page 38 - Call up the connection settings menu. - Activate the control via cloud server. Warning. If this function is activated, WLAN connection faults of the home router can lead to temporary communication failures with ventilation units. Manual – AlphaFreshbox 200 WiFi...
  • Page 39 - Add a new connection by pressing the button - Enter the name of the ventilation unit and ID. The ID number of the ventilation unit is indicated on the control board. - The default password is 1111. Manual – AlphaFreshbox 200 WiFi...
  • Page 40 - Confirm the entered data by pressing the key - Press the key if necessary to log out. Manual – AlphaFreshbox 200 WiFi...
  • Page 41 Menu structure Manual – AlphaFreshbox 200 WiFi...
  • Page 42 Red light - alarm indicator, orange light - warning indicator Heat dissipation indicator of the electric heating coil before the system is switched off Boost Boost operation indicator The current temperature of the sensor that controls the air temperature. Manual – AlphaFreshbox 200 WiFi...
  • Page 43 Basic settings - Timer menu Recirculation: Activation of the recirculation mode. If there is no recirculation mode, the key is inactive. Heating register: Selection of the temperature setpoint for the post-heating register or switching off the heating register. Manual – AlphaFreshbox 200 WiFi...
  • Page 44 (boost switch) on the control board disappears. Boost switch-on delay: determines the switch-off delay time for boost mode after the signal at the digital input (boost switch) has been applied. Manual – AlphaFreshbox 200 WiFi...
  • Page 45 Time setting for a specific period of time Selection of the control temperature +15 ° С.. + 30 ° С, off are available. If OFF is selected, temperature control is not executed during timed operation. Manual – AlphaFreshbox 200 WiFi...
  • Page 46 In this menu, the current time and date are displayed and their settings are also made. Time display format: HH:MM:SS Date format: DD.MM.YYYY Manual entry of date and time The same time as on the mobile device is set automatically. Manual – AlphaFreshbox 200 WiFi...
  • Page 47 Total operating time: shows the running time of the unit, which cannot be reset. Other The backlight changes dynamically, after releasing the button the brightness decreases to a preset value. Sound - switches the loudspeaker on the board on/off. Manual – AlphaFreshbox 200 WiFi...
  • Page 48 Engineering menu Air flow rate Air flow rate, preset ventilation level 1-5 and boost are set in this section. Manual – AlphaFreshbox 200 WiFi...
  • Page 49 Supply air temperature Exhaust air temperature in front of the heat exchanger Exhaust air temperature behind the heat exchanger Firmware This menu shows the current version and date of the control unit and control panel firmware. Manual – AlphaFreshbox 200 WiFi...
  • Page 50 The ventilation system is forcibly switched off. The alarm is reset manually with the Reset alarms button. Warning - the system is not forcibly switched off. Warnings are automatically reset after the cause has been eliminated. Manual – AlphaFreshbox 200 WiFi...
  • Page 51: Emergency Stop

    Remote control connection error with the control unit (not shown in the app). • — — — — Wifi module initialisation error • • • • • Unknown error (contact your dealer if this error occurs). Manual – AlphaFreshbox 200 WiFi...
  • Page 52: Error Codes/Warnings

    Alarm! Feueralarm-Aktivierung Warnung! Der Filterwechsel-Timer ist abgelaufen. Wechseln Sie den Filter. Alarm! Keine Verbindung zum Bedienfeld und zur Steuereinheit Alarm! Kein zusätzlicher Zulufttemperatursensor vor dem Hauptheizregister Alarm! Kurzschluss des zusätzlichen Zulufttemperatursensors vor dem Hauptheizregister Manual – AlphaFreshbox 200 WiFi...
  • Page 53: Troubleshooting

    Make sure the air ducts are clean and intact. Loud noise, Dirty fan impellers Clean the impellers. vibrations The screw Tighten the fastening screws. connection is loose. Manual – AlphaFreshbox 200 WiFi...
  • Page 54: Maintenance And Servicing

    Remove the dirty filters from the unit: Clean F7 filters with a hoover. To remove the G4 filters for cleaning, remove the flexible fixing clips. Rinse the filters with water and let them dry. Manual – AlphaFreshbox 200 WiFi...
  • Page 55 A hoover with a narrow suction nozzle is best suited for this. Pull the heat exchanger out of the ventilation system, clean it with a hoover and put it back into the ventilation system. Manual – AlphaFreshbox 200 WiFi...
  • Page 56 Even if you carry out all the recommended maintenance regularly, some dust may get into the ventilation pipes and thus reduce the delivery rate and volume flow. Maintenance consists of regular cleaning or replacement of the ventilation pipes. Manual – AlphaFreshbox 200 WiFi...
  • Page 57: Transport And Storage

    Transport the unit only in the operating position. Carry out loading and unloading operations carefully, protect against shocks. Before first use after transport at low temperatures, the unit must be kept at room temperature for at least 3-4 hours. Manual – AlphaFreshbox 200 WiFi...
  • Page 58: Disposal

    The product complies with the European norms and standards, directives on low voltage and electromagnetic compatibility. We hereby declare that the product complies with the relevant requirements of Directive 2014/30/EU on electromagnetic compatibility, Voltage Directive 2014/35/EU and Directive 93/68/EEC on CE marking. Manual – AlphaFreshbox 200 WiFi...
  • Page 59 - Failure by the consumer to carry out timely technical maintenance of the appliance. - In the event of external damage to the housing and internal units caused by the consumer (except for external modifications to the unit that are necessary for assembly). Manual – AlphaFreshbox 200 WiFi...
  • Page 60 - Violation of regulations concerning the storage of the appliance by the consumer. - Illegal actions by third parties in relation to the appliance. - Failure of the appliance due to force majeure (fire, flood, earthquake, war, military action of any kind, blockades). Manual – AlphaFreshbox 200 WiFi...
  • Page 61 Contact the seller of the unit for warranty service. In the event of a warranty claim, we recommend that you contact us first. To obtain this warranty service, please contact us at: info@radontec.de Manual – AlphaFreshbox 200 WiFi...
  • Page 62: Support And Contact

    Should you have any further questions or require further help and technical support, please do not hesitate to contact us. RadonTec GmbH Hauptstraße 5 89426 Wittislingen - Germany Tel: (+49) 9076 - 919 98 35 E-Mail: info@radontec.de Website: radontec.de Shop: radonshop.com Manual – AlphaFreshbox 200 WiFi...

Table of Contents