Instruction Manual / Manual de Uso
UL CE
NT-XX-RV-AF series All function temperature controller
RoHs
Thank you very much for using FOTEK NT-XX-RV series All function Temperature controller
Please read this instruction manual before operating it to avoid from the malfunction.
FOTEK
NT10-R-AF / NT-22-R-AF / NT-48RV / NT-72-RV / NT-20-RV / NT-21-RV / NT96-RV-AF
■ Specification / Especificaciones:
Type
Model
Output method
Rated current
Operating voltage
Alarm output
Control method
I
nput method
Display range
Accuracy of display
Setting range
Dielectric strength
Isolation strength
Operating temp
Housing material
■ Mode of alarm / Modos de Alarma
ALt
Description / Descripción
AL1 ON
SV
0
AL2 ON
SV
AL1 ON
(SV – AL2)
SV
3
AL2 ON
SV
AL1 ON
6
AL2 ON
AL1 ON
First cycle unable
(SV - AL1)
SV
9
AL2 ON
SV
AL1 ON
12
AL2 ON
AL2
1
AL1 ON
SV (SV+AL1)
15
AL2 ON
SV
AL1 ON
SV
18
AL2 ON
SV
1
AL1 ON
SV (SV+AL1)
21
AL2 ON
First cycle unable
(SV - AL1)
SV
1
AL1 ON
SV (SV+AL1)
24
AL2 ON
(SV - AL1)
SV
1.
「ALt=15」 :t = ON time of AL2 for cooling, OFF time is controlled by PID.
2.「ALH」 :Hysteresis of alarm. Ex. PV≧(SV+AL1)→AL1 ON, PV<(SV+AL1-ALH)→AL1 OFF
3.「tnu」= Process time of tnr, if「tnu≧tnr」→ AL2 is turned ON or OFF
https://www.fotek.com.tw
DIN 48*48
NT-48RV-AF
ALt
Description / Descripción
AL1 ON
(SV+AL1)
1
AL2 ON
(SV+AL2)
AL1 ON
(SV+AL1)
4
AL2 ON
(SV+AL2)
AL1 ON
AL1
7
AL2 ON
AL2
AL1 ON
(SV+AL1)
10
AL2 ON
(SV+AL2)
AL1 ON
AL1
13
AL2 ON
AL1 ON
Flicker
16
AL2 ON
(SV+AL2)
(SV+AL1)
19 Non-used
tnr
99m59s
Flicker
AL1 ON
22
AL2 ON
(SV+AL2)
Flicker
AL1 ON
25
AL2 ON
(SV+AL2)
DIN 72*72 /48*96 /96*96
NT-XX-RV-AF
Relay & SSR
Relay (5A/250VAC) ;SSR(30mA/12V)
90~265VAC 50/60Hz
Relay (5A/250VAC)
PID + Fuzzy
PT / K / J / R / S / T/ B / E / N / L Selectable
-999 ~ 9999 或 -99.9 ~ 999.9 Selectable
± ( 0.1 % of F.S. + 1 DIGIT)
-999 ~ 9999 或 -99.9 ~ 999.9 Selectable
Over 2.5KV
Over 100MΩ / 500VDC
﹣20℃ ~ ﹢80℃;35 ~ 85%RH
Intensive PC+ABS(UL-94V0)
(SV - AL1)
SV
SV
(SV+AL2)
(SV – AL1) SV
(SV+AL1)
SV
(SV+AL2)
First cycle unable
AL1
AL2
SV
(SV+AL1)
SV
tnr
99h59m
SV
(SV+AL1)
(SV – AL2)
SV
SV
(SV+AL1)
SV
tnr
99h59m
1
Flicker
SV (SV+AL1)
(SV - AL1)
SV
1
Flicker
SV (SV+AL1)
(SV - AL1)
SV
(SV+AL2)
AlltronicsPerú
AUTOMATIZACIÓN INDUSTRIAL
DIN 24*48
NT-10-AF
Relay or SSR
ALt
Description / Descripción
AL1 ON
(SV - AL1)
SV
2
AL2 ON
(SV – AL2)
SV
AL1 ON
(SV - AL1)
SV
5
AL2 ON
SV
AL1 ON
First cycle unable
(SV - AL1)
SV
8
AL2 ON
SV
AL1 ON
11
AL2 ON
AL2
AL1 ON
SV
14
AL2 ON
(SV – AL2) SV
AL1 ON
SV
17
AL2 ON
SV
tnr
1
AL1 ON
SV (SV+AL1)
20
AL2 ON
SV
1
AL1 ON
SV (SV+AL1)
23
AL2 ON
(SV - AL1)
SV
AL1 ON
AL1
SV
26
AL2 ON
First cycle unable
(SV – AL2) SV
https://alltronicsperu.com
F - 71
(SV+AL1)
(SV+AL2)
(SV+AL2)
AL1
(SV+AL1)
(SV+AL1)
99m59s
Flicker
(SV+AL2)
Flicker
Need help?
Do you have a question about the FOTEK NT-RV Series and is the answer not in the manual?
Questions and answers