2. Cycle the main burner On and Off at least
three times. The main burner must ignite each
time within four seconds.
3. Wait at least three minutes for the BASO power
unit to drop out and extinguish the main burner
flame.
If the BASO power unit does not drop out, reduce
the pilot flame further and repeat Steps 2 and 3.
Technical Data
Product
Materials
Maximum Temperature
Agency Listing
Specification Standards
Performance specifications are nominal and conform to acceptable industry standards. All agency certification of BASO products is performed
under dry and controlled indoor environmental conditions. Use of BASO products beyond these conditions is not recommended and may void
the warranty. Product must be protected if exposed to water (dripping, spraying, rain, etc.) or other harsh environments. The original
equipment manufacturer or end user is responsible for the correct application of BASO products. Consult BASO Gas Products LLC for
questionable applications. BASO Gas Products LLC shall not be liable for damages or product malfunctions resulting from misapplication or
misuse of its products.
Refer to the J Series Pilot Burners/Y90 Series Inlet Fittings Product Bulletin (BASO-PB-PILOTS/Y90) for necessary information on operating
and performance specifications of this product.
450 East Horseshoe Road
PO Box 170
Watertown, WI 53094
1-877-227-6427 (1-877-BASOGAS)
© 2017 BASO Gas Products
Part No. BASO-INS-J99xREPLACEMENT, Rev. B
J99x Series BASO Replacement Pilot Burners
Mounting Bracket
Pilot Tip
Pilot Body
Inlet Tip
Inlet Body
Mounting Bracket
Pilot Tip
Pilot Body
Inlet Tip
Inlet Body
None
ANSI Z21.20
CAN1-6.4
CAN/CSA-C22.2 No. 199-M89
J99x Series BASO® Replacement Pilot Burners
If you cannot secure ignition of the main burner
when the pilot flame has been reduced to the point
at which the BASO power unit drops out, the pilot
is located too far from the main burner and must
be moved closer. Relocate the pilot and repeat
Steps 2 and 3.
4. Return the pilot to normal operation by turning the
manual B valve to the fully open position.
Plated Steel
430 Stainless
Plated Steel
Aluminum
Brass
825F (441C)
1500F (816C), (D Tip 1350F [732C])
825F (441C)
635F (335C)
750F (399C)