Summary of Contents for Panasonic TX-29RX20M-MALAYSIA
Page 1
ORDER NO. MTV0701596CE Colour Television TX-29RX20M- MALAYSIA GP41Z Chassis Specifications Power Source : AC SINGLE 220-240 V, 50/60 Hz Receiving Channels : Power Consumption : 95 W 2-12 PAL / SECAM B, K1 Aerial Impedance : 75 Ω unbalanced 0-12 PAL B (AUSTRALIA) Coaxial type 1-9 PAL B (N.
TX-29RX20M-MALAYSIA Monitor Out at zero beam current 1 Vp-p, 75 Ω Video Out Picture Tube : A68MAU085X23 Approx. 0.5 V, 1 k Ω Audio Out 68 cm (29 inches) Intermediate Frequency : Measured diagonally, Video 38.0 MHz 90° deflection Sound 31.5 MHz (D, K, K1)
TX-29RX20M-MALAYSIA 1 Safety Precautions 1.1. General Guidelines 1. It is advisable to insert an isolation transformer in the AC supply before servicing this hot chassis. 2. When servicing, observe the original lead dress, especially the lead dress in the high voltage circuits. If a short circuit is found, replace all parts which have been overheated or damaged by the short circuit.
TX-29RX20M-MALAYSIA 1.4. X-Radiation Warning: The potential sources of X-Radiation in TV set are the EHT section and the picture tube. When using a picture tube test jig for service, ensure that the jig is capable of handling 32.5 kV without causing X-Radiation.
TX-29RX20M-MALAYSIA 2 Factory Mode Setting 2.1. Set to Factory Mode 1. Press the factory set button on the remote and the volume down (front control) button together, then the white pattern will appear. In case of releasing the remote button, the black pattern will appear or in other case the volume bar (Volume down) appears.
TX-29RX20M-MALAYSIA 3 Service Mode Adjustment 3.1. Service Mode Access 1. Set the timer ON. 2. Press remote’s RECALL ( ) and panel’s volume down key simultaneously to enter SERVICE 1. 3.2. Service Mode 1 Controls Key 3/4 Previous/Next Service 1 Item...
TX-29RX20M-MALAYSIA 4 Service Hints 4.1. Service Position for E-Board 1. Remove the back cover. 2. Stand the TV set as shown in Fig. 2. 3. Remove the A-Board from the TV set by pulling the main board out as shown in Fig. 2.
TX-29RX20M-MALAYSIA 4.3. Adjustment for CRT CUT OFF Preparation: 1. Connect the oscilloscope probe to (GREEN CATHODE) on L Board. 2. Screen VR min. 3. Set the data Sub Bright, Bright. 4. In service Mode at “Bright” dac press [5] in factory mode to enter vertical line and adjust by volume down or up button.
TX-29RX20M-MALAYSIA 4.5. Adjustment of Purity 1. INSTRUMENTS a. Purity Jig b. Helmhortz device 2. PREPARATION a. Set the Helmhortz device to local magnetic field. Horizontal : 0 ± 0.03 × 10-4T b. Aging should have been performed over 60 minutes.
Page 11
TX-29RX20M-MALAYSIA ADJUSTMENT OF CONVERGENCE 1. INSTRUMENT a. Helmhortz device 2. PREPARATION a. Set the Helmhortz device to local magnetic field. Horizontal : 0 ± 0.03 × 10-4T b. Receive the crosshatch pattern. c. Picture menu : DYNAMIC Normal and adjust BRIGHT DAC until gray portion of crosshatch.
Page 12
TX-29RX20M-MALAYSIA FOCUS ADJUSTMENT 1. PREPARATION a. Receive crosshatch pattern E-4. b. Picture menu : DYNAMIC NORMAL For Philippines & Panamex model a. Receive the crosshatch pattern. ( US 6 ) b. Picture menu : DYNAMIC NORMAL 2. ADJUSTMENT a. Adjust focus VR for best position.
Page 13
TX-29RX20M-MALAYSIA DEFLECTION Note:- For Philippines model, all 50 Hz adjustment is made in AV mode. A . DEFLECTION ADJUSTMENT / CONFIRMATION (50 Hz, 4:3 Mode ONLY) (Service 1) 1. INSTRUMENT a. Helmhortz device 2. PREPARATION a. Set the Helmhortz device to local magnetic field.
Page 14
TX-29RX20M-MALAYSIA B . DEFLECTION ADJUSTMENT / CONFIRMATION (50 Hz, 4:3 Mode ONLY) (Service 1) 1. INSTRUMENT a. Helmhortz device 2. PREPARATION a. Set the Helmhortz device to local magnetic field. b. Picture menu : DYNAMIC Normal 3. CONFIRMATION AND ADJUSTMENT a.
Page 15
TX-29RX20M-MALAYSIA 4. ADJUSTMENT OF 50 Hz H-AMP a. Receive the monoscope pattern (E11). b. Adjust H-AMP so that both edges are within 2.5 ± 0.2. Refer to Fig. 1. Fig. 1 5. EW ADJUSTMENT / CONFIRMATION a. PREPARATION a. Receive crosshatch pattern (E4).
Page 16
TX-29RX20M-MALAYSIA (16:9 MODE) ADJUSTMENT / CONFIRMATION 1. V-ZOOM (16:9) ADJUSTMENT (Service 3) *a. Receive PAL monoscope pattern E11. (If no burst signal : Set to force PAL) b. Set the aspect to 16:9. c. Confirm that A, B in Fig. 1 is 4.0 cm ± 1.5, if not, adjust V-ZOOM.
Page 17
TX-29RX20M-MALAYSIA 1. Confirmation of deflection setting, if not in spec, touch up as below :- (Service 3) A) For 60 Hz (4:3 only) : a. Adjustment of 60 Hz V-CENTER a. Receive the monoscope pattern (US13). b. Adjust V-POS 60 Hz offset so that centre of monoscope pattern is at CRT centre.
Page 18
TX-29RX20M-MALAYSIA B) For other Deflection touch up 50 & 60 Hz ; 4:3 & 16:9 1. Adjustment of V-Sym a. Adjust V-SYM so that a=b in Fig. 1 Fig. 1 2. Adjustment of V-LIN a. Adjust V-LIN a=b=c=d in Fig. 2.
Page 19
TX-29RX20M-MALAYSIA 6. Adjustment of BOW a. Adjust BOW so that the vertical lines are straight. (Fig. 6) Fig. 6...
TX-29RX20M-MALAYSIA 7 Schematic Diagram Notes : 1. Resistor All resistors are carbon 1/4 W resistors unless marked as follows : Unit of resistance is OHM (Ω) (K = 1 000 M = 1 000 000) 2. Capacitor All capacitors are ceramic 50 V capacitors unless marked as follows : Unit of capacitance is µF unless otherwise noted.
Page 24
TX-29RX20M-MALAYSIA 8. When an arrow mark ( ) is found, connection is easily found from the direction of the arrow. : Indicates the major signal flow. 10. This schematic diagram is the latest at the time of printing and subject to change without notice.
TX-29RX20M-MALAYSIA 9 Replacement Parts List Note : Printed circuit board assembly with “NLA” is no longer available after production discontinuation of the complete set. Abbreviation of part name and description 1. Resistor 2. Capacitor Example : Example : ERD25TJ104 C 100 kΩ, J, 1/4 W ECKF1H103ZF C 0.01 µF, Z, 50 V...
Page 44
TX-29RX20M-MALAYSIA 9.1. Replacement Parts List Ref. Part No. Part Name & Description Remarks C363 F2A1C101A310 E 100UF, 16V Ref. Part No. Part Name & Description Remarks C366 F2A1C470A310 E 47UF, 16V C368 ECA2EM100B E 10UF, 250V A68MAU085X43 C370 F1J1H222A590 C 2200PF, 50V...
Page 45
TX-29RX20M-MALAYSIA Ref. Part No. Part Name & Description Remarks Ref. Part No. Part Name & Description Remarks C654 ECJ1VF1H104Z C 0.1UF, Z, 50V D511 MA4108J DIODE C655 ECJ1VF1H104Z C 0.1UF, Z, 50V D512 B0HAJL000003 DIODE C656 ECJ1VC1H270J C 27PF, J, 50V...
Page 46
TX-29RX20M-MALAYSIA Ref. Part No. Part Name & Description Remarks Ref. Part No. Part Name & Description Remarks L550 J0JKB0000034 EMI FILTER R1065 ERJ3GEYJ121 M 120OHM,J,1/16W L554 ELC08D682E CHOKE COIL R1066 ERJ3GEYJ152 M 1.5KOHM,J,1/16W L557 G0D320000003 LINEARITY COIL R1067 ERJ3GEYJ470 M 47OHM,J,1/16W...
Page 47
TX-29RX20M-MALAYSIA Ref. Part No. Part Name & Description Remarks Ref. Part No. Part Name & Description Remarks R368 ERDS1TJ152 C 1.5KOHM,J, 1/2W R644 ERJ3GEYJ103 M 10KOHM,J,1/16W R372 ERQ12AJ121P F 120OHM,J,1/2W R645 ERJ3GEYJ101 M 100OHM,J,1/16W R381 ERJ3GEYJ182 M 1.8KOHM,J,1/16W R646 ERJ3GEYJ183...
Page 48
TX-29RX20M-MALAYSIA Ref. Part No. Part Name & Description Remarks Ref. Part No. Part Name & Description Remarks K1KA06AA0180 CONNECTOR RL831 K6B1CDA00028 RELAY K1KA06AA0659 CONNECTOR RM1062 B3RAD0000160 REMOCON RECEIVER K1KA02A00676 CONNECTOR K1KA03AA0190 CONNECTOR K1KA02A00720 CONNECTOR SC352 K3B09CA00014 CRT SOCKET K1KA04AA0190 CONNECTOR...