Marc Pro is intended for muscle conditioning by stimulating muscle in order Marc Pro, Inc. 5702 Bolsa Ave. to improve or facilitate muscle performance. Marc Pro is not intended to be Huntington Beach, CA 92649 used for therapy or treatment of medical diseases or medical conditions.
Page 4
10. Do you suffer from cardiac problems or diseases? If you answered “Yes”, “Maybe” or “I Don’t Know” to any one or more questions, do not use the device and contact Marc Pro for more information. If you answered “No” to all 10 questions, you...
Page 5
CONTRAINDICATIONS | Do not use Marc Pro if you have one or more of the following 3. Electrodes used for electrical stimulation should not be applied across the medical conditions: chest because the introduction of electrical current into the chest may cause 1.
INDICATIONS FOR USE | “Marc Pro” is intended for muscle conditioning by stimulating muscle in order to improve or facilitate muscle performance. “Marc Pro” is not intended to be used for therapy or treatment of medical diseases or medical conditions.
Page 7
• For blood fl ow defi ciencies On or near the The Marc Pro uses RF energy only for its internal function. Therefore, its RF emissions are very low and are vicinity of skin not likely to cause any interference in nearby electronic equipment. If any nearby electronic equipment lesions or eruptions shows any signs of malfunctioning stop using the Marc Pro immediately.
Page 8
CONTENTS | Included Supplies: Your Marc Pro is supplied with the following unique accessories developed for optimal results. • Marc Pro device P/N M4 • 6 packages of electrodes P/N 70011 • 2 lead wires P/N 51021 / 51022 • 1 recharger P/N 51018 •...
Page 9
“Instructions” or “TIMER”. To use the timer, press “SET” until “Care of your Marc Pro” sections. desired treatment time is shown on the display, then press “START/STOP” to start or stop your timer.
• If you’re using an optional aloe based • Only use the electrodes supplied by Marc Pro. skin gel: use a small amount (about the Other electrodes may present a risk of unsuitable • When done recharging always remember to size of a pea) under each electrode.
Page 11
INSTRUCTIONS | Step 4 Marc Pro has two intensity knobs, each of which, when spun clockwise, click into the “ON” The intensity level goes from 0.0 to 9.0 and is Take out a package of electrodes and remove position and activate the LCD screen and the from Ziploc bag.
Page 12
For conditioning and enhanced performance, the only difference is consistency. Using Marc Pro proactively (e.g., 1-2 times per day, 3 or more days per week) creates the conditioning benefi ts that will not only help muscles recover better, but also help them perform better.
Marc Pro channels is used It’s important to realize that electrode placement best judge of electrode placement. If the target to activate numerous muscles at the same time.
Page 14
VISIT MARCPRO.COM FOR INTERACTIVE PAD PLACEMENT VIDEOS AND TIPS |...
Page 15
If the target muscles are not being the day. Using Marc Pro the next day or any time activated or if the activation is not strong enough, after soreness has set in will still be effective, but reposition the electrodes to fi...
Page 17
QUADRICEPS CHANNEL INTENSITY S E T T I N G S...
Page 18
CALVES ALTERNATIVE PLACEMENT CHANNEL INTENSITY S E T T I N G S...
Page 19
HAMSTRINGS CHANNEL INTENSITY S E T T I N G S...
Page 20
SINGLE WHOLE LEG FOCUS ALTERNATIVE PLACEMENT CHANNEL INTENSITY S E T T I N G S...
Page 21
HIP FLEXOR CHANNEL INTENSITY S E T T I N G S...
Page 22
GROIN CHANNEL INTENSITY S E T T I N G S...
Page 23
GLUTES CHANNEL INTENSITY S E T T I N G S...
Page 24
LOWER EXTREMITY - UNIVERSAL CHANNEL INTENSITY S E T T I N G S...
Page 25
GLOBAL ARM FLUSH USE CHANNEL B ON RIGHT ARM CHANNEL Inside of arm between bicep and tricep at front INTENSITY edge of armpit S E T T I N G S...
Page 26
MID ARM USE CHANNEL A ON LEFT ARM CHANNEL INTENSITY S E T T I N G S...
Page 32
TRAPS AND MID BACK CHANNEL INTENSITY S E T T I N G S...
Page 33
The following examples show how you can activate more muscle groups at the same time, which can be helpful for those with numerous target areas for improvement. The compromise is that each muscle group is stimulated less than in the previous “Focused Target Area”...
Page 34
GLOBAL LEG FLUSH ALTERNATIVE PLACEMENT CHANNEL INTENSITY S E T T I N G S...
Page 35
QUADRICEPS AND HAMSTRINGS CHANNEL INTENSITY S E T T I N G S...
Page 36
LOW BACK AND QUADRICEPS CHANNEL INTENSITY S E T T I N G S...
Page 37
TRAPS AND LOWER BACK CHANNEL INTENSITY S E T T I N G S...
Page 38
QUADRICEPS AND CALVES CHANNEL INTENSITY S E T T I N G S...
Page 39
Your needs and your responses will decide and dictate the best electrode placements. Remember that Channels A and B are completely independent. Channel A can be used on one muscle or group of muscles, while Channel B can be used on another. For example Channel A might be used to address muscles in your left arm;...
– It may be time to change to a new set of Cleaning Your Unit: electrodes. To clean your Marc Pro, use a cloth and an (see “Electrode Care”). alcohol-based cleaning product, which does not – Try fully charging your battery.
Need help?
Do you have a question about the M4 and is the answer not in the manual?
Questions and answers