Procedure:
1.
To determine the experiment settings, first connect to your chosen device (PC,
Mac, tablet, smart device) and click on the "Off-line experiment" icon after the
sensor search has ended. (For more information on how to change the
experiment settings, view the quick start procedure section for your chosen
device in this document.)
2.
Connect the heart rate and pulse sensor directly to the left side of a charged
BAT-200 module.
When ready to collect data, press the "Start/Stop" button on the heart rate and
3.
pulse sensor, a red light will turn on for the duration of the experiment.
After the experiment has concluded (the "Start/Stop" button is pressed again or
4.
the data collection period ends) connect the sensor to your chosen device (you
can find full instructions in each device's quick start procedure section).
5.
Open the NeuLog application.
Click the "Off-line experiment" icon.
6.
Click the "Load data from sensors" icon.
7.
8.
Select which experimental data to upload (5 experimental runs can be stored at
one time on the NUL-208 heart rate and pulse sensor).
Restoring sensor's factory default settings:
Procedure:
1.
Connect the USB-200 to a PC, Mac, tablet, or smart device.
2.
Connect the heart rate and pulse sensor to a USB-200 module (they directly
plug together).
3.
Open the NeuLog application.
Click the "Tools" icon.
4.
Click the "Restore sensor's factory defaults" on the menu.
5.
NEULOG HEART RATE AND PULSE LOGGER SENSOR GUIDE
Included with the sensor:
NeuLog NUL-208 Heart Rate and Pulse Sensor Guide (this document)
Fingertip/earlobe clip with IR receiver transmitter
Range and
operation modes
ADC resolution
Accuracy
Resolution
Max sample rate
(S/sec)
Experiment Duration: 1 second to 31 days.
Sensor features:
Fully digital data
Rugged plastic ergonomic case
Push button switch for Start/Stop experiments in off line mode
LED indicator of experiment status (blinks while collecting data)
Pre-calibrated sensing equipment
Pulse sensing electrodes located in the probe clips attached directly to the
sensor's plastic body
Note: NeuLog products are intended for educational use.
Videos and experiment examples:
Videos, literature and other probes can be found at www.NeuLog.com.
In order to access the heart rate and pulse sensor's page, choose "Products" on
the main menu and then "Heart rate and pulse ".
In order to find the science experiments, choose "Experiments" on the main
menu of the NeuLog website, then choose "Physics", "Chemistry", "Biology" or
"Environmental Science".
Sensor specifications
Arbitrary analog
Beats per minute
units (wave
function)
0-1023 Analog
0 to 240
values
10 bit
1
1
1
100