CX-WLTFM TURBINE FLOW METER
CX-WLTFM TURBINE FLOW METER
User manual
Tel:86-21-57632436
Fax:86-21-57634942

Advertisement

loading
Need help?

Need help?

Do you have a question about the CX-WLTFM and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GN CX-WLTFM

  • Page 1 Shanghai Cixi instrument Co., ltd www. gnflowmeter.com CX-WLTFM TURBINE FLOW METER CX-WLTFM TURBINE FLOW METER User manual Tel:86-21-57632436 Fax:86-21-57634942...
  • Page 2 Shanghai Cixi instrument Co., ltd www. gnflowmeter.com Summary Turbine flow meter control panel adopts Modular design, Computer modules are local full-featured and easy-to-use with Simple structure and clear interface. shows, it is For this manual, we have introductions about the way for jumper settings and the use of buttons Please read this manual carefully and operate the control panel accordingly.
  • Page 3 Shanghai Cixi instrument Co., ltd www. gnflowmeter.com 4.Jumper definition and connection Jumper J2: Choice between normal working status and automatic flow calibration status Factory III. Functions and operating instructions Figure 1 Buttons’ operation, LCD display to indicate their location (see Figure 1) 1.
  • Page 4 Shanghai Cixi instrument Co., ltd www. gnflowmeter.com 2. Work and dormancy status When the panel works normally, The liquid flows through or to operate the buttons, the control panel LCD shows work status; No liquid flows through or to operate the buttons, one minute later the control panel will be in dormancy status, LCD does not display;...
  • Page 5 Shanghai Cixi instrument Co., ltd www. gnflowmeter.com Numerical after "c" ( such as 46.33 ) is the modified flow coefficient (k) value, the number of flashes that can be modified, and modify the scope: 0 to 9, the position can be shifted by press the “CALIBRATE”...
  • Page 6 Shanghai Cixi instrument Co., ltd www. gnflowmeter.com Maintenance The computerized electronic meters can work at least 9,000 hours (one year) as the battery power. In most cases, the batteries are required to be replaced for one year. Prior to the demolition of the battery on sealed meter will extend batteries life.
  • Page 7 Shanghai Cixi instrument Co., ltd www. gnflowmeter.com Ⅶ Ⅶ Ⅶ Ⅶ .Fault resolution FAULTS REASONS RESOLUZTIONS 1. On-site calibration method is not 1. Re-calibration on-site or scene correct. Data selection for Factory calibration. 2. Factory calibration is not suitable for inaccurate 2.