  • Page 1 GasCheck Tesla Instrument User Manual V1.2R Register your instrument online to receive your extended Warranty. Unrivaled Detection. ionscience.com/usa...
  • Page 2 Register your instrument online for extended warranty Thank you for purchasing your ION Science instrument. The standard warranty of your instrument can be extended up to two years. To receive your extended warranty, you must register your instrument online within one month of purchase ( terms and conditions apply.)
  • Page 3: Declaration Of Conformity

    Declaration of conformity The EU Authorised Representative of the manufacturer Ion Science limited has sole responsibility, on the date this product accompanied by this declaration is placed on the market, the product conforms to all technical and regulatory requirements of the...
  • Page 4: Table Of Contents

    GasCheck Tesla Instrument User Manual V1.2R Contents Declaration of conformity ............................. 3 Statements ................................5 Safety ....................................5 Quality Assurance ................................5 Responsibility of use................................. 5 Disposal .................................... 5 Calibration Facility ................................5 Legal Notice ..................................5 Instrument Description ............................6 Packing list ................................
  • Page 5: Statements

    "as is" and without any representation, term, condition or warranty of any kind, either express or implied. To the extent permitted by law, Ion Science shall not be liable to any person or entity for any loss or damage which may arise from the use of this manual.
  • Page 6: Instrument Description

    Magnetic Resonance Imaging (MRI) scanners and can be effectively used while the machinery is still in operation. GasCheck Tesla is part of a range of gas leak detectors used for detecting gas leaks, and can detect almost all gases to varying degrees.
  • Page 7: Packing List

    Item Description Check GasCheck Tesla instrument with short probe and nozzle fitted Long probe Box spanner used to change probes Spare battery clip...
  • Page 8: How Gascheck Tesla Works

    6 times faster. The GasCheck Tesla contains a heated thermistor bead that transmits heat to a block of material that remains at a constant temperature. As air passes through the detector chamber a constant amount of heat passes from the bead to the block.
  • Page 9: Instrument Main Menu

    Instrument main menu Once the GasCheck Tesla has run through its 'Start up' routine it will display its normal 'Running screen' used when locating gas leaks. Before using the instrument the various settings should be set and adjusted to suit the application.
  • Page 10: Running Screen

    Gas selection The GasCheck Tesla displays the gas being measured in the top left of the running screen. The GasCheck Tesla will display the gas as selected at the factory, however the Tesla has a range of gases that can be selected via an internal gas table.
  • Page 11: Functions

    Functions Contrast Use this function to adjust the contrast of the GasCheck Tesla's LCD (Liquid Crystal Display). Significant variations in ambient light conditions can cause the display to appear too dark or faint. When this function is selected a number will appear to the right of the Contrast symbol as a percentage.
  • Page 12: Battery Selection

    = Cubic Centimeters per second offers a volumetric leak rate that directly measures the volume of a gas escaping from a given point, it is also known as ml/sec (milliliters per second). The GasCheck Tesla can typically detect Helium leaks down to 0.0005 of a cubic centimeter per second.
  • Page 13: Gas Selection

    Functions Gas selection GasCheck Tesla is calibrated using Helium gas at manufacture, however other gases can be detected and measured using a gas table within the instrument. Although GasCheck Tesla can't differentiate between gases it can quantify other gases using response factors stored in its internal gas table.
  • Page 14: Getting Started

    GasCheck Tesla Instrument User Manual V1.2R Getting started The Keypad All GasCheck Tesla models have the same keypads, the following section explains the general functionality of each key:- ESCAPE This key is used to return the display to Use the UP key to scroll through...
  • Page 15: Using Gascheck Tesla

    Ensure the instrument is on the X100 (times one hundred) range, while on the main running screen use the UP and DOWN key to adjust between sensitivity ranges. X100 is most sensitive, X1 is the least sensitive. Gas leaks tend to occur at pneumatic joints or welded seams, hold the GasCheck Tesla at a 45 angle to the object being tested and drag the probe along the seam or joint at a rate of approximately 25mm per second.
  • Page 16: Gascheck Tesla Fan Current Monitor

    In the event of the fan current constantly exceeding 600 units, for example if the GasCheck Tesla fan has reached the end of its working life, the unit will not display the leak rate and the GasCheck Tesla should be returned to ION Science for servicing.
  • Page 17: Probe Options

    WARNING: Ensure safety guidelines are adhered to when using compressed air. (ION Science Inc takes no responsibility for injury or damage caused by misuse of compressed air equipment) Unrivaled Detection. ionscience.com/usa...
  • Page 18: Detecting Leaks

    - GasCheck Tesla can detect changes in Humidity and Carbon dioxide, therefore avoid breathing on the probe. - The thin white tube that covers the inner probe should not be removed, this tube ensures a 1mm gap is maintained between the probe and the surface being tested.
  • Page 19: Calibration

    ' units then the instrument must be calibrated using a 5000 ppm Helium concentration. If the GasCheck Tesla is used to detect leaks measured using 'cc/sec' units then the instrument must be calibrated using a 0.0005 cc/sec (5 E ) Helium leak.
  • Page 20: Calibration Procedure Using 'Cc/Sec' Units

    Used A-21500 0.0005 cc/sec Helium Calibration kit For when GasCheck Tesla is used with cc/s units WARNING: Great care should be taken to ensure the calibration gas is neither pressurized or restricts flow to the instruments probe. Changes in flow of gas to the sensor will result in significant errors in readings.
  • Page 21: Replacing Batteries

    The battery holder can be reconnected to the GasCheck Tesla by firmly pressing the two halves of the PP3 clip together. Care should be taken to ensure the polarity is correct, see the PP3 Battery holder diagram (right).
  • Page 22: Instrument Specification

    GasCheck Tesla Instrument User Manual V1.2R Instrument specification Operating temperature 0 to 50 °C 32 to 122 °F Storage temperature -25 to 70 °C -13 to 158 °F Instrument case Polyurethane Dimensions L.390 x W.60 x H.50 mm L15.35” x W2.35” x 2.0 “...
  • Page 23: Replacement Parts

    GasCheck Tesla Instrument User Manual V1.2R Replacement parts Part Item Number Long probe A-08045 Short probe A-08043 Replacement battery holder 3000 1/BH-01 Nozzle 08024CPC8 Box Spanner A-08029 Accessory Item Number CalCheck A-21500 (specifying gas, leak rate and pressure) Unrivaled Detection.
  • Page 24: Instrument Warranty And Service

    GasCheck Tesla Instrument User Manual V1.2R Instrument warranty and service Warranty Standard Warranty can be extended to up to 2 years on the GasCheck Tesla when registering your instrument via our website: www.ionscience.com/usa To receive your Extended Warranty, you need to register within one month of purchase (Terms and Conditions apply).
  • Page 25: Manual Log

    Disclaimer: Information in this [manual, document…] is subject to change without notice and does not represent a commitment on the part of Ion Science. No claims, promises or guarantees are made about the accuracy, completeness, or adequacy of the information contained herein.
  • Page 26 GasCheck Tesla Instrument User Manual V1.2R Addendum • GasCheck Tesla is suitable for use in magnetic field strengths of ≤ 2T at least 2m from an MRI opening. – 19 March 2021 • It’s possible to use the instrument in higher magnetic fields but please contact ION Science for more information if your magnetic field is >...