Korenix JetCon 2502 V2 Quick Start Manual

Advertisement

Quick Links

JetCon 2502 V2
Quick Installation Guide v1.0
Copyright
Copyright © 2014 all rights reserved. No part ofthis publication may
be reproduced, adapted, stored in a retrieval system, translated into
any language, or transmitted in any form or by any means without
the written permission ofthe supplier.
Aboutthe Quick Installation Guide
This Quick Installation Guide is intended to guide professional
installer to install and configure the JetCon 2502 V2. It covers
procedures to assist you in avoiding unforeseen problems.
Introduction
JetCon 2502 V2 is an Ethernet/POTS to VDSL2 extender. It allows the
VDSL2 carriers to deliver Ethernet data up to 100Mbps in both
upstream and downstream over existing twisted copper. It is an ideal
solution to carry Ethernet Data stream to 2500 meters far away to
extend local LAN and voice on the same line.
Package Check List
 JetCon 2502 V2 Industrial Media Converter
 Quick Installation Guide
 Power Adapetr (Optional)
Installation
Mountthe unit
Screwed up the DIN-rail clip on the rear of
JetCon 2502 V2 and mount on the
EN50022 type rail. For more details, please
refer to user's manual.
Wiring the Power Inputs
1. Insert the positive and negative wires into
the V+ and V- contacts respectively of the
terminal block connector.
2. Tighten the wire-clamp screws to prevent
loosened.
3. The terminal block input and DC jack input
supports power redundancy.
4. The Chassis Earth Ground must well connect with Earth Ground to
provide good electrical magnetic immunity.
Note:
The recommended working voltage is DC 12V.
(Input range: DC10~ 60 V)
Connecting the VDSL2 Network
1. Take out two JetCon 2502 V2 from the package box; one emulate
CO site (local), and the other one is CPE site (remote).
2. Apply the power into JetCon 2502 V2 and check the power LED
status to make sure JetCon 2502 is ready.
3. Set the mode selection dip switch 1 to "on" to enable master
function on JetCon 2502 in the local site; the other JetCon 2502 V2
in the remote site should be off.
4. Connect PC to the 10/100Mbps RJ-45 connector of both JetCon
2502 V2 with standardized Ethernet cable.
5. Connect the VDSL2 ports of two JetCon 2502 V2 by one pair UTP
cable and check the VDSL LED status to make sure the VDSL
connection is ready. Please refer to below LED indicators.
6. Check the LED Ethernet port of both sites are ready.
LED Indicator
There are 3 LED in JetCon 2502 V2 and 2 LED RJ-45 Connector.
LED
Status
Description
Yellow on
Link on 100Mbps
Fast Ethernet
Speed (RJ-45)
Off
Link on 10Mbps or no link.
Green on
The port is link on 10 or 100Mbps
Fast Ethernet
Link/Activity
Blinking
The port is on transmitting/receiving data.
(RJ-45)
Off
There is no device attached.
Green Fast
VDSL in handshake state
Blinking
VDSL
Green Slow
VDSL is active and in idle state
Blinking
Green On
VDSL communication is ready
Ethernet/VDSL Extender is working on Master
Green on
mode.
Master
Green off
Ethernet/VDSL Extender is working on Slave mode.
Green on
The power is applied.
Power
Blinking
No power.
DIP Switch Setting
JetCon 2502 V2 provides 4 DIP switches for
system configuration; each DIP switch has
independent function. Please refer to the
following description.
DIP Switch -1: Mode selection.
Master mode (On): Acts as Central office (master).
Slave mode (Off): Acts as remote office (slave).
DIP Switch -2/3/4: Profile selection.
There are 8 different kinds of selection. Details listed as below.
Note:
Each JetCon 2502 V2 mode should correspond to central (master) or
remote (slave) installation. The default setting is slave mode (off)
DIP Switch
Profile #
Profile Config
1
2
3
4
Profile 1 OFF OFF OFF OFF M_Sy_Auto_G.inp
Profile 2 OFF OFF OFF ON M_NSy_Auto_G.inp
Profile 3 OFF OFF ON OFF M_Sy_Auto_I
Profile 4 OFF OFF ON
ON M_NSy_Auto_I
Master
Profile 5 OFF ON OFF OFF M_Sy_Auto_G.inp
Profile 6 OFF ON OFF ON M_NSy_Auto_G.inp
Profile 7 OFF ON
ON OFF M_Sy_30a_G.inp
Profile 8 OFF ON
ON
ON A_17a-eu32_I
Slave
ON
-
-
-
-
Note:
1. The cable length should under 800 meters to make 24/24 dB
effective.
2. For more profile config explanation, please refer user's manual.
Support
5 Years Warranty
Each of Korenix's product line is designed, produced, and tested with
high industrial standard. Korenix warrants thatthe Product(s) shall be
free from defects in materials and workmanship for a period offive (5)
years from the date of delivery provided thatthe Product was properly
installed and used.
This is warranty is voided if defects, malfunctions or failures ofthe
warranted Product are caused by damage resulting from force measure
(such as floods, fire, etc.), other external forces such as power
disturbances, over spec power input, or incorrect cabling; or the
warranted productis misused, a bused, or operated, altered and
repaired in an unauthorized or improper way.
Attention! To avoid system damage caused by sparks, please DO NOT
plug in power connector when power is on.
The productis in compliance with Directive 2002/95/EC and 2011/65/EU
ofthe European Parliament and ofthe Council of 27 January 2003 on the
restriction ofthe use of certain hazardous substances in electrical and
electronics equipment (RoHS Directives & RoHS 2.0)
Korenix Customer Service
KoreCARE is Korenix Technology's global service center, where our
professional staff are ready to solve your problems at any time Korenix
global service center's e-mail is KoreCARE@korenix.com.
For more information and documents download please visit our website:
http://www.korenix.com/downloads.htm
Rate Limit
SNR
DS/US
DS/US
(Mbps)
(dBm)
160/160
8/8
220/110
8/8
160/160
6/6
220/110
6/6
150/150
12/12
200/100
12/12
20/20
24/24
150/50
6/6
-
-

Advertisement

loading

Summary of Contents for Korenix JetCon 2502 V2

  • Page 1 Profile # Profile Config DS/US DS/US 5. Connect the VDSL2 ports of two JetCon 2502 V2 by one pair UTP (Mbps) (dBm) the written permission ofthe supplier. cable and check the VDSL LED status to make sure the VDSL Profile 1 OFF OFF OFF OFF M_Sy_Auto_G.inp...
  • Page 2 传输速度 信噪比 何语言,或以任何形式或方式传播。 3. 将模式选择拨码开关1设置为“on”,启用JetCon 2502的CO站 Profile # Profile Config 上传/下载 上传/下载 点功能; 另一个CPE站点JetCon 2502 V2的 Switch 1应该关闭。 (Mbps) (dBm) 关于快速安装指南 Profile 1 OFF OFF OFF OFF M_Sy_Auto_G.inp 160/160 4. 使用标准的以太网电缆将PC连接到JetCon 2502 V2的10 / 本“快速安装指南”旨在指导专业安装人员安装和配置JetCon Profile 2 OFF OFF OFF ON M_NSy_Auto_G.inp 220/110 100Mbps RJ-45连接器。...