1. Center a 6" thick concrete base around installed BFP.
A. Place expansion material around riser pipe and place conduit for electrical power before placing
concrete. CONCRETE SHOULD BE FINISHED ABSOLUTELY LEVEL, FLAT AND
SMOOTH. Allow concrete to cure.
B. Mark concrete with outside dimensions of enclosure. Center enclosure around BFP.
2. Using four (4) hexhead screws for each section assemble each "A-B" (end and side)
sections thru holes provided. Set on marked concrete base (FIG 2).
3. Set "D1" (roof) panel on "A-B" sections. Using two (2) hexhead screws fasten thru holes provided (Fig 1).
A. "Temporarily" place "F" (center) post in position.
4. Position "D2" (roof) panel over edge of "D1" (roof) panel and set on other "A-B" section. Using two (2)
hexhead screws fasten thru holes provided (Fig 1).
5. On top inside of roof, using ten (10) hexhead screws attach Inner Roof Connection Bracket (Fig 1E) to
"D1" (roof), "D2" (roof) and both "F" (side) posts. (This will cover the wood members in the center of
the top and secure the top to the "F" post.)
6. A. Using one (1) hexhead screw attach Outside Corner Anchoring Brackets to "A-B" sections. Fasten
bracket to concrete using one anchor for each bracket (FIG 1A).
B. Square the "A-B" corners. Align the "B" panels so that they form a straight line. Using one (1) hexhead
screw and one (1) hit pin for each bracket attach Inside Anchoring Brackets to "B" panels and concrete
(FIG 1B).
C. Insert Inside Roof Clips in "D" (roof) panel. Using one (1) hexhead screw in each clip attach clip to
"B" (side) panel (FIG 1C).