Page 1
01-9999-86 Rev. 6/13 AQ111 Fill Kit Instructions for filling the eye wash cartridges 1. Open the AQ111 box. Inside you will find two expiration date labels, a funnel, and two eye wash Cartridges with a few ounces of Hydrosep in each bag. Figure 1: Fill Kit packed in Box.
Page 2
3. With the bag laid out on a flat, stable surface, insert the valve of the Aquarion bag through the hole and slide it back into the thinner slot to keep the bag in place. Figure 3: Aquarian Valve slid into slot. 4.
Page 3
5. Place the funnel in the open valve and press down gently to secure it in place. 6. Fill the bag with 3.7-4.0 gallons of potable water (14.0-15.1 L). Note: Filling the cartridge with the correct amount of water is critical to the system meeting the ANSI Z358.1 Standard.
Page 4
Figure 6: Aquarion Expiration Label. See Installation, Operation, Maintenance Manual 01-9999-72 for instructions on installing the Cartridges.