Download Print this page

ENCON Aquarion AQ111 Instructions

Fill kit

Advertisement

Quick Links

AQ111 Fill Kit
Instructions for filling the eye wash cartridges
1. Open the AQ111 box. Inside you will find two expiration date labels, a funnel,
and two eye wash Cartridges with a few ounces of Hydrosep in each bag.
2. On one of the box flaps you will see a perforated cut, press firmly on this
perforated area to remove the cardboard.
1
Figure 1: Fill Kit packed in Box.
Figure 2: Perforation cut out.
01-9999-86
Rev. 6/13

Advertisement

loading

Summary of Contents for ENCON Aquarion AQ111

  • Page 1 01-9999-86 Rev. 6/13 AQ111 Fill Kit Instructions for filling the eye wash cartridges 1. Open the AQ111 box. Inside you will find two expiration date labels, a funnel, and two eye wash Cartridges with a few ounces of Hydrosep in each bag. Figure 1: Fill Kit packed in Box.
  • Page 2 3. With the bag laid out on a flat, stable surface, insert the valve of the Aquarion bag through the hole and slide it back into the thinner slot to keep the bag in place. Figure 3: Aquarian Valve slid into slot. 4.
  • Page 3 5. Place the funnel in the open valve and press down gently to secure it in place. 6. Fill the bag with 3.7-4.0 gallons of potable water (14.0-15.1 L). Note: Filling the cartridge with the correct amount of water is critical to the system meeting the ANSI Z358.1 Standard.
  • Page 4 Figure 6: Aquarion Expiration Label. See Installation, Operation, Maintenance Manual 01-9999-72 for instructions on installing the Cartridges.