  • Page 1 The Tapworks Whole Home Filter Installation and Operation Manual How to install, operate and maintain your Central Water Whole Home Filtration System...
  • Page 2 Tapworks Model TWHF Central Water Whole Home Filtration System Specifications Flow rate at 1 bar pressure drop 41.6 litres/min.* Maximum day time pressure 4.76 bar Minimum day time pressure 1.7 bar Supply water temperature limits (minimum/maximum) 5-49 °C Drain flow rate 12.9 litres/min.
  • Page 3: Unpacking And Inspection

    Unpacking and Inspection Packing List...
  • Page 4: How A Central Water Filtration System Works

    How a Central Water Filtration System Works Normal operation Applications for a Central Water Filtration System During normal operation water enters the Central Water Filtration System and flows through several filtration • Do not use the Central Water Filtration System with processes where tastes, odours and sediment* are reduced.
  • Page 5: Installation Requirements

    Installation Requirements Location requirements Consider the following when selecting an installation • The Central Water Filtration System works on location for the Central Water Filtration System. 24 volt, 50 Hz electrical power only, supplied by • Do not operate the Central Water Filtration System a direct plug-in transformer (included).
  • Page 6 Installation Requirements Air Gap requirements Valve Drain requirements A drain is needed for Refresh discharge water. A drain Using the flexible drain hose (included), measure and cut close to the Central Water Filtration System is preferred. to the length needed. A standpipe is another drain option.
  • Page 7: Start-Up Procedure

    Start up Procedure Important During the start up cycle: Run the start up cycle immediately after completing installation, before using Throughout the start up cycle you will hear the valve any water in the home. changing position and notice the flow of water to drain starting and stopping.
  • Page 8: Programming The Electronic Controller

    Programming the Electronic Controller Controller settings required Upon installation, and after an extended power outage. When the transformer is plugged into the electrical outlet, a model code (LCF) and a test number (example: J1.6), are briefly shown in the faceplate display. Then the words “SET TIME” appear and “12:00”...
  • Page 9: Controller Features/Options

    Controller Features/Options Set number of days between clean rinse cycles By default the Central Water Filtration System will automatically initiate a Clean Rinse every 14 days. This should be sufficient for most applications. To change the number of days between Clean Rinse cycles: 1.
  • Page 10 Controller Features/Options Operating in manual clean rinse mode Clean Rinse cycles will run automatically, unless the automatic Clean Rinse function has been disabled. If this function has been disabled, it will be necessary to manually initiate any Clean Rinse cycles. It is recommended that a Clean Rinse cycle should be run at least once each month, or more frequently if necessary.
  • Page 11: Wiring Schematic

    Wiring Schematic...
  • Page 12 Tapworks, Mill Road, Stokenchurch, Bucks HP14 3TP Direct Service Line: 0870 429 9019 Fax: 01494 484 312 info@tapworks.co.uk www.tapworks.co.uk As part of our policy of ongoing research and development, we reserve the right to alter design and specification without prior notice.