Download Print this page

Samlexpower IDC-360 Series Instruction Manual page 2

Advertisement

IDC-360 |
InstruCtIonal Manual
DIMensIons & laYout
1
5
LEGEND
1. Input +
4. Output +
5. Chassis Ground
2. Input -
3. Output -
6. Fan Suction Vents
Fig. 2 Layout (Front View)
speCIfICatIons
MoDel
Input VoltaGe
no.
ranGe (VDC)
IDC-360A-12
9 - 18
IDC-360B-12
20 - 35
IDC-360C-12
30 - 60
IDC-360D-12
60 - 120
IDC-360A-24
9 - 18
IDC-360B-24
20 - 35
IDC-360C-24
30 - 60
IDC-360D-24
60 - 120
IDC-360B-48
20 - 35
IDC-360C-48
30 - 60
no loaD Current DraW
Input to output IsolatIon
output rIpple & noIse
peaK effICIenCY
CoolInG
operatInG teMperature
HuMIDItY, non-ConDensInG
proteCtIons
safetY anD eMC stanDarDs
eMISSION
IMMuNIty
AutOMOtIve DIreCtIve
Input / output ConneCtIons
DIMensIons (W x D x H) MM/InCH
WeIGHt (KG/lB)
NOte: Specifications are subject to change without notice
11004-IDC-360-0413
(continued)
6
2
3
4
91mm
AT THE BACK (NOT SHOWN):
- Fan
- Fan Exhaust Vents
MaX Input
output
Current (a)
VoltaGe (VDC)
Current (a)
<40
12.5
<30
12.5
<20
12.5
<10
12.5
<40
24.5
<30
24.5
<20
24.5
<10
24.5
<30
48.0
<20
48.0
< 25 mA
Yes. > 400V RMS
< 50 mV RMS
85%
By temperature controlled fan
-20 to +30oC / -4oF to 86oF
(de-rate linearly to zero at 70oC / 158oF)
Max 95%
Overload / short circuit on the output
side; Over voltage on the output side;
Over voltage / transients on the input
side; Reverse polarity on the input side;
Over heating
EN50081-1 / EN61000-6-3
EN50082-1 / EN61000-6-1
95/54/EC
(IDC-360A & IDC-360B Series only)
Quick Connect male 6.3 mm /
1/4" flat blade
132.8 x 190.5 x 83 / 5.23 x 7.5 x 3.27
1.4 / 3.1
taBle 1.
exterNAl INput SIDe FuSe & WIrINg
MoDel
naMe
IDC-360A-12, 24
IDC-360B-12, 24, 48
IDC-360C-12, 24, 48
IDC-360D-12, 24
83
mm
taBle 2.
exterNAl Output SIDe FuSe & WIrINg
MoDel
naMe
IDC-360A-12
IDC-360B-12
IDC-360C-12
IDC-360D-12
IDC-360A-24
IDC-360B-24
IDC-360C-24
IDC-360D-24
IDC-360B-48
IDC-360C-48
note 1:
a)
Wire sizes shown are based on 2% voltage drop over distance of 3' from input source
or load for current = Amp rating of the fuse.
output
b)
For distances > 3', use thicker wires to limit voltage drop to <2% for current = Amp
the fuse.
rating of
30
30
2 Year lIMIteD WarrantY
30
30
IDC-360 manufactured by Samlex America, Inc. (the "Warrantor") is warranted to be
15
free from defects in workmanship and materials under normal use and service. The
15
warranty period is 2 years for the United States and Canada, and is in effect from the
date of purchase by the user (the "Purchaser").
15
Warranty outside of the United States and Canada is limited to 6 months. For a
15
warranty claim, the Purchaser should contact the place of purchase to obtain a
7.5
Return Authorization Number.
7.5
The defective part or unit should be returned at the Purchaser's expense to the
authorized location. A written statement describing the nature of the defect, the
date of purchase, the place of purchase, and the Purchaser's name, address and
telephone number should also be included.
If upon the Warrantor's examination, the defect proves to be the result of defective
material or workmanship, the equipment will be repaired or replaced at the
Warrantor's option without charge, and returned to the Purchaser at the Warrantor's
expense. (Contiguous US and Canada only)
No refund of the purchase price will be granted to the Purchaser, unless the
Warrantor is unable to remedy the defect after having a reasonable number of
opportunities to do so. Warranty service shall be performed only by the Warrantor.
Any attempt to remedy the defect by anyone other than the Warrantor shall render
this warranty void. There shall be no warranty for defects or damages caused by
faulty installation or hook-up, abuse or misuse of the equipment including exposure
to excessive heat, salt or fresh water spray, or water immersion.
No other express warranty is hereby given and there are no warranties which
extend beyond those described herein. This warranty is expressly in lieu of any other
expressed or implied warranties, including any implied warranty of merchantability,
fitness for the ordinary purposes for which such goods are used, or fitness for a
particular purpose, or any other obligations on the part of the Warrantor or its
employees and representatives.
There shall be no responsibility or liability whatsoever on the part of the Warrantor
or its employees and representatives for injury to any persons, or damage to
person or persons, or damage to property, or loss of income or profit, or any
other consequential or resulting damage which may be claimed to have been
incurred through the use or sale of the equipment, including any possible failure of
malfunction of the equipment, or part thereof. The Warrantor assumes no liability for
incidental or consequential damages of any kind.
samlex america Inc. (the "Warrantor")
www.samlexamerica.com
WIre sIZe
fuse speCs
(see note 1 BeloW)
32V, 40A
AWG#10
32V, 30A
AWG#10
80V, 20A
AWG#12
125V, 10A
AWG#12
WIre sIZe
fuse speCs
(see note 1 BeloW)
32V, 30A
AWG#10
32V, 30A
AWG#10
32V, 30A
AWG#10
32V, 30A
AWG#10
32V, 15A
AWG#12
32V, 15A
AWG#12
32V, 15A
AWG#12
32V, 15A
AWG#12
58V, 7.5A
AWG#18
58V, 7.5A
AWG#18
DC-DC Converter Manual
| 2

Advertisement

loading

This manual is also suitable for:

Idc-360a-12Idc-360b-12Idc-360c-12Idc-360d-12Idc-360a-24Idc-360b-24 ... Show all