Check the voltage and size of the fuse required on the rating plate attached to the cabinet. The
supply socket must be earthed and protected by a 10 A slow fuse. No other appliances may be
connected to the same fuse.
NOTE
All electrical connections must be carried out by approved and qualified personnel
and comply with all IEE and local regulations, failure to do this could result in
personal or fatal injury.

4. Operation

Cooling is achieved by a fan evaporator system. The evaporator is located at the bottom of the
cabinet's tray. Cold air is blown to the shelves through the perforated side wall.
The cabinet is equipped with a Dixell XR02CX controller.

4.1. Starting up

1. Connecttheplugtothesupplysocket.
The compressor and fans start operating.
2. Waitfor90minutesoruntilthedesiredtemperatureisreached.
The cabinet is now ready to be filled.

4.2. Loading cabinet

• Positiontheproductscarefully.
• Do not fill the cabinet above the load limits marked in the cabinet.
See figure 2 on the inside cover.
• Do not exceed the load limit.
Exceeding the load limit will disrupt the designed airflow pattern and cause the temperature
of products to rise.
• Donotdroporthrowproductsintothecabinet.
NOTE
The cabinet is not designed to cool down products but to maintain them at the
temperature at which they are placed in the cabinet. Food products warmer than
the specified temperature should not be placed in the cabinet.

4.3. Setting operating thermostat

The operating thermostat for the cabinet is located in the panel on the side of the cabinet's bottom
part. The thermostat is preset to the correct temperature at the factory.
Version03/2015
ENGLISH
6