Safety Relays from IDEM
User Information
The SEU-1 contact block in combination with any basic device
Correct Use
from the IDEM SCR series can be used to produce up to three
additional safety contact paths per device. An existing system can
thus be expanded practically indefinitely in a modular manner.
Activation takes place via a safety contact of the basic device, the
SEU-1 provides signaling contacts for fault monitoring. The
devices can be used in machines and systems up to safety cate-
gory 4, PL e according to EN ISO 13849-1.
3 safe, redundant relay outputs
Features
1 auxiliary contact (fault monitoring)
Activation via basic device from the IDEM SCR series
Modular, freely configurable safety system
Fault monitoring by basic device
Earth fault monitoring
Indication of the switching state via LED
Up to category 4, PL e, SILCL 3
Function
The safety expansion module SEU-1 in combination with a
basic device from the IDEM SCR series is designed for
safe isolation of safety circuits according to EN 60204-1
and can be used up to safety category 4, PL e according to
EN ISO 13849-1.
Terminal S11 (DC 24 V control voltage) is connected with
terminals S15 and S16 via the safety contacts of the basic
device. Starting the basic device also activates the SEU-1.
The basic device disconnects the control voltage when the
safety switch is operated, and the safety contacts of the
SEU-1 open immediately.
If a fault occurs in the SEU-1, this is detected by the basic
device via terminals S23 and S24.
Independent operation without basic device is not
possible.
Installation
As per EN 60204-1, the device is intended for installation in
control cabinets with a minimum degree of protection of
IP54. It is mounted on a 35 mm DIN rail according to DIN
EN 60715 TH35.
Installation and commissioning of the device must be
Safety
performed only by authorized personnel.
Precautions
Observe the country-specific regulations when installing
the device.
The electrical connection of the device is only allowed to
be made with the device isolated.
The wiring of the device must comply with the instruc-
tions in this user information, otherwise there is a risk
that the safety function will be lost.
It is not allowed to open the device, tamper with the
device or bypass the safety devices.
When the 24 V version is used, a control transformer
Electrical
according to DIN EN 61558-2-6 or a power supply unit
Connection
with electrical isolation from the mains must be connect-
ed.
External fusing of the safety contacts (6 A gG) must be
provided.
A maximum length of the control lines of 1000 meters
with a line cross section of 0.75 mm
ceeded.
The line cross section must not exceed 2.5 mm
If the device does not function after commissioning, it
must be returned to the manufacturer unopened. Open-
ing the device will void the warranty.
Fig. 1 Block diagram SEU-1
Fig. 2 Installation / removal
All relevant safety regulations and standards are to be
observed.
The overall concept of the control system in which the
device is incorporated must be validated by the user.
Failure to observe the safety regulations can result in
death, serious injury and serious damage.
Note down the version of the product (see label "Ver: x")
and check it prior to every commissioning of a new de-
vice. If the version has changed, the overall concept of
the control system in which the device is incorporated
must be validated again by the user.
SEU-1
13 23
K1
K2
14 24
2
must not be ex-
2
.
SEU-1
(not for plug-in terminals)
A1:
Power supply
A2 :
Power supply
S11:
DC 24 V control voltage
S10:
Control line
S15:
Control line
33
S 23
S16:
Control line
34
S 24
S23:
Fault monitoring
S24:
Fault monitoring
13-14:
Safety contact 1
23-24:
Safety contact 2
33-34:
Safety contact 3
Fig. 3 Connections
H04
Ver. A
E61-326-00

Advertisement

loading

Summary of Contents for Idem SEU-1

  • Page 1 The basic device disconnects the control voltage when the safety switch is operated, and the safety contacts of the SEU-1 open immediately. If a fault occurs in the SEU-1, this is detected by the basic device via terminals S23 and S24. Independent operation without basic device is not Fig.
  • Page 2 Applications Depending on the application, the device must be wired with a IDEM basic device as shown in Fig. 1 to Fig. 2.If the devices are wired inside a control cabinet (minimum degree of protection IP54), the fault involving a short circuit between the activa- tion lines can be ruled out (protected wiring space).
  • Page 3 Additional data can be requested from the manufacturer for applications that deviate from these conditions. According to EN ISO 13849-1 Safety characteristics according to EN ISO 13849-1 for all variants of SEU-1 Load (DC-13; 24 V) <= 0.1 A <= 1 A <= 2 A...
  • Page 4 SEU-1, AC/DC 24 V (AC: 50-60 Hz), plug-in terminals Ver. A E61-326-00 IDEM SAFETY SWITCHES Ltd, 2 Ormside Close, Hindley Industrial Estate ,Hindley Green, Wigan, WN2 4HR UK, Tel: +44 (0)1942 261000 Fax.: +44 (0)1942 676293 IDEM ( U.S.A.) - 3909 Washington Blvd. 204, Fremont, CA 94538 email: sales@idemsafety.com...

This manual is also suitable for:

Seu-td1