Do you have a question about the CPTH-12 and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for ClimaTemp Portables CPTH-12
Page 1
OPERATION MANUAL OPERATION MANUAL CPTH-12 READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT INSTALLATION AND USAGE, AND READ ALL SAFEGUARDS PORTABLE HEAT PUMP...
OPERATION MANUAL SERIAL NUMBER LOCATION AND IDENTIFICATION The serial number and name plate can be located near the lower right side of the unit. Nameplate Label Nameplate Location...
Page 3
OPERATION MANUAL FOREWARD The first portable Heat Pump featuring optional Cold Plasma Needlepoint Bipolar Ionization. • Eliminates viruses and bacteria. • Effective on airborne and surface pathogens. • Neutralizes odors and VOC’s • Reduces mold spores, pollen, allergens and particulates. •...
Page 4
After unpacking your ClimaTemp Portable Heat Pump, please check to make sure you have the following items: 1. CPTH-12 Portable Heat Pump. 2. Operation Manual. 3. Kick Plate/Foot Pedal. (located under the unit). Please attach to bottom rear of unit.
Page 5
OPERATION MANUAL INSTALLATION & GENERAL SAFETY INFORMATION • Unit Designed for indoor usage only. Do not submerge or spray water on the spot cooler. • Do not use the unit at conditions above 95 ℉ in cooling mode or below 40 ℉ in heating mode.
Page 6
OPERATION MANUAL When in operation, the front and back of the machine should be more than 20" from the wall or other barrier. The cold air exhaust should be at least 12" away from any barrier and hot air exhaust should be more than 79" from roof or barrier.
Page 7
OPERATION MANUAL INSTALLATION (cont.) Moving the Unit Unlock the casters and push the Portable Heat Pump unit using the side handles to a flat, level surface and set the casters to the LOCKED position.
Page 8
Procedure for Testing Device The CPTH-12 is equipped with a LCDI power cord. This device is non-serviceable and opening the device may cause electric shock or void the warranties of the product.
Power/Run Fan Speed OPERATION MANUAL CTHP-12 Portable Heat Pump OPERATION Control Panel Before operating the unit, it is important to familiarize yourself with the basic controls located on the control panel.
Page 10
OPERATION MANUAL OPERATION (cont.) Operating Method 1. Power Switch: After plugging into power, the power switch LED indicator will illuminate, press the POWER button to turn on and turn off the unit. 2. Air volume selection: Press Fan Speed to select the high or low air volume. 3.
Page 11
OPERATION MANUAL 5. To operate in Cooling mode. Make sure Power button is on then press the cooling button. Press the temperature button, the temperature button will start to blink. Press the up and down adjustment button on the display to set the temperature you desire. Once selected wait 15 seconds and your preferred temperature will be set.
Page 12
OPERATION MANUAL 8. Alarm indicator/Unit error: When the unit’s condensate bucket is full of water, or an overcurrent, overheat, or other trouble is detected by the unit, the alarm indicator will turn on. When the unit stops working, LED display will show the error code.
Page 13
OPERATION MANUAL LED Display Error Codes: Code Description Reason Compressor Over-current Surrounding Temperature too high Protection or to low. Hot or cold air exhaust is obstructed. Input voltage is too high or too low. Compressor problem. Relay problem. Check and clean filters. Pressure too high in refrigerant Surrounding Temperature too high system...
Page 14
OPERATION MANUAL OPERATION (cont.) Empty the Drain Tank During operation condensate water accumulates in the drain tank. When the drain tank becomes full, an audible chirping sound can be heard and LED displays “FL”, then the unit will cut off the power supply and stop. Note: If you want to empty the drain tank, please wait after the unit stops.
Page 15
OPERATION MANUAL OPERATION (cont.) Note: The condensed water can be directly discharged through a gravity drain. Remove the drain tank, connect the drain outlet directly to the machine through the bottom side discharge hose or out through the right-side discharge hose outlet. Optional Condensate Pump: Installation procedure for ClimaTemp condensate plug and play pumps.
OPERATION MANUAL DAILY INSPECTION & MAINTENANCE Empty the Drain Tank To empty the drain tank, refer to instructions on page 13. Clean the Air Filters Clean the air filters once a week. If the unit is used in a dusty environment, more frequent cleaning may be required.
Page 17
OPERATION MANUAL Filter Cleaning Method 1. Remove filters. Dust, dirt and particulate can be removed from the filter with a vacuum cleaner, or rinse in cold or lukewarm water. If the element is extremely dirty, wash with a neutral detergent. 2.
OPERATION MANUAL TROUBLESHOOTING Check the following items before calling your ClimaTemp reseller or a qualified technician. CONDITION POSSIBLE CAUSE REMEDY Unit does not 1. Ground fault breaker trip or Reset breaker or reset LCDI power cord. operate breaker trip from power source.
EXPRESS OR IMPLIED, INCLUDING BY WAY OF EXAMPLE AND NOT LIMITATION, THE IMPLIED WARRANTIES OF TITLE, MERCHANTABILITY, NONINFRINGEMENT AND FITNESS FOR A PARTICULAR PURPOSE. LIMITATION ON LIABILITY NOTWITHSTANDING ANYTHING HEREIN TO THE CONTRARY, IN NO EVENT WILL CLIMATEMP PORTABLES BE LIABLE FOR ANY SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES WHATSOEVER, INCLUDING LOSS OF PROFITS, WHETHER ARISING IN CONTRACT, TORT, WARRANTY OR OTHERWISE, EVEN IF IT HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.