1. Remove the body in accordance with "REMOVE OF BODY".
2. Disconnect 3 lead wires from the triac.
3. Remove 2 screws holding the triac to the heater tank ass'y.
4. Now the triac is free.
Screw
Triac
1. Remove the body in accordance with "REMOVE OF BODY".
2. Disconnect reed SW. lead wires from the PCB control ass'y.
3. Remove 2 screws holding the reed SW. from the body valve.
4. Now the reed SW. is free.
Note : Tighten the mounting screws of the reed switch at the specified torque ; 3-4 kgf.cm.
Reed SW.
REMOVE OF TRIAC
Fig. 22
REMOVE OF REED SWITCH
Screw
Brown lead wire
Triac lead wire
White lead wire
Breaker lead wire
Heater tank
Fig. 23
11
Reed SW. lead wire
Body valve