Summary of Contents for Auvon PB111

  • Page 2: Table Of Contents

    1. Introduc�on........................2. Understand Your Meter&Display&Strip................Meter Display Strip Code Chip Lancet Device & Lancet 3. Important Informa�on......................Before Tes�ng 4. Opera�on..........................Installing the Ba�ery Set up Your Meter (�me/buzzer/alarms/HI&LO value) Preparing for Your Lancing Device Coding Your Meter Perform the Blood Glucose Tes�ng Normal Glucose Value Clean the Meter 5.
  • Page 3: Introduc�On

    Introduc�on Thank you for choosing the AUVON PB111 Veterinary Blood Glucose Monitoring System. The AUVON PB111 Veterinary Blood Glucose Monitoring System will provide accurate blood glucose results from fresh whole blood samples in just a few simple steps. The AUVON PB111 Veterinary Blood Glucose Monitoring System is intended for using outside the body of dogs and cat.
  • Page 4: Understand Your Meter&Display&Strip

    PB111 Veterinary PB111 Veterinary Understand Your Meter & Display & Strip Glucose Meter -02-...
  • Page 5 -03-...
  • Page 6 Display (Defaults:mg/dl) -04-...
  • Page 7 Strip AUVON PB111 Veterinary Blood Glucose Test Strips work with the AUVON PB111 Veterinary Blood Glucose Meter to measure the glucose concentra�on in whole blood from your animal. Only apply sample to the -05-...
  • Page 8: Code Chip

    Code Chip AUVON PB111 Veterinary Blood Glucose meter kit contains 2 code chips for coding the meter. The following number on the code chip is for reference only, please refer to the actual product for the code. IMPORTANT: 1. Before inser�ng the test strip, please code the meter with the correct code chip.
  • Page 9: Lancet Device & Lancet

    Lancet Device & Lancet A. Depth Se�ng Dial (Choose the depth by rota�ng the dial. Suggest to set it to the deepest level B. Lancing Bu�on (Press to obtain blood sample.) C. Locking Lever (Pull back un�l it clicks. ) D.
  • Page 10: Important Informa�On

    Temperatures beyond the required range, as well as humidity, can damage test strips and lead to inaccurate results. Any change of medica�ons based on the AUVON PB111 Veterinary Blood Glucose Monitoring System results without advices of a veterinarian is NOT RECOMMENDED.
  • Page 11: Opera�On

    Only AUVON PB111 Veterinary Test Strips can be used with this meter. For accurate results, tests must be done within the opera�ng temperature range (10 - 40°C/ 50 - 104°F). Opera�on Note: When the meter enters the blood collec�on interface, the meter will turn off automa�cally if there is no opera�on within 3 mins.
  • Page 12 1. As shown below, place your thumbs 4. Place the ba�ery cover to on each dot part and then push up the the dot part as shown below ba�ery cover. (Fig. 01) 2. Push up the and press the cover to match ba�ery cover to the dot part as shown the notch.
  • Page 13: Set Up Your Meter (�Me/Buzzer/Alarms/Hi&Lo Value)

    Set up Your Meter (�me/buzzer/alarms/HI&LO value) Your AUVON PB111 Veterinary Blood Glucose Meter comes with the date, �me, beep sound, alarm and unit of measurement preset. However; if you change the �me or replace the ba�ery, you should check the �me and date.
  • Page 14 1. Set date 2. Set �me -12-...
  • Page 15 2. Set �me 3. Set buzzer 4. Set alarm -13-...
  • Page 16 When "ON" mode is confirmed, press un�l the desired hour and minute is displayed. Press to confirm. 4. Set alarm When "OFF" mode is confirmed, the meter will enter the "ON" or "OFF" se�ng of the second alarm, and the rest alarms can be set in turn.
  • Page 17 to set HI&LO value of cat. 5. Set HI&LO value -15-...
  • Page 18: Preparing For Your Lancing Device

    Preparing for Your Lancing Device -16-...
  • Page 19 6. Pull the plunger un�l it to the deepest number. (Be�er clicks. Set aside un�l to get enough blood sample.) star�ng the test. -17-...
  • Page 20: Coding Your Meter

    Coding Your Meter the animal 1. dog ear location with lancing device 2. dog elbow callous with lancing 3. dog lip with la (For reference only, please refer to the actual product for approaching location device approaching location ing location the code.) 1.
  • Page 21 chip chip and the code number on the strip bo�le . pproach- 4. dog paw pad (side) with lancing device approaching location The meter will turn off automa�cally. If the test strip is not pulled out, the meter will turn off in 2 mins. pproach- 4.
  • Page 22: Perform The Blood Glucose Tes�Ng

    Perform the Blood Glucose Tes�ng Please use the AUVON PB111 Veterinary Blood Glucose Test Strips. Other test strips can produce inaccurate results. The test strips are for single use only. 1. dog ear location with lancing device 2. dog elbow callous with lancing 3.
  • Page 23 and orient pet owners to location) 7. meter with te Selec�ng a Tes�ng Site on Cats: drawn (any loca 5. cat ear (marginal ear vein) with lanc- 6. cat paw pad (side) with lancing dog lip, but we a ing device approaching location device approaching location strip which is wh Marginal ear vein.
  • Page 24 touching blood drop that has been ent on which reads best… thinking e’s a curve toward the bottom of the hould touch the strip 5. The meter is wai�ng for the blood sample while the blood drop icon is flashing. none 6.
  • Page 25 automa�cally. The test results will be saved. -23-...
  • Page 26: Normal Glucose Value

    1. The meters opera�ng range: 10 C~40 C (50 F~104 2. Always check the code number on the screen matches that on the vial you use before tes�ng. Code your meter with coding sec�on if not. Normal Glucose Value Clean the Meter -24-...
  • Page 27: Memory Func�On

    Memory Func�on Note: The meter will display the dog data first, and then the cat. Without the blood sugar data of the dog, the meter won't show the average data of the dog. -25-...
  • Page 28: Care And Storage

    Understand the test result: represents the number of the memory data, and the interface will scroll to show each data. Care and Storage 1. Please handle the meter with care. Dropping the meter may result in damage. 2. Do not expose the meter, test strips to extreme condi�ons such as high humidity, heat, freezing cold, or dust.
  • Page 29: Display Messages

    Display Messages The AUVON PB111 Veterinary Blood Glucose Meter has built-in messages to alert you of problems. When error messages appear, note the error numbei, turn off the meter and then follow these instruc�ons. -27-...
  • Page 30 °C °C °F °F °C °C °F °F °C °C -28-...
  • Page 31 -29-...
  • Page 32: Q&A

    Q&A What should you do if the test results are very different? Please check if: 1. The wrong pet’s code chip is selected. 2. The test strip is not within the validity period. 3. The pet has a great emo�onal response during blood collec�on. 4.
  • Page 33 What will cause the blood sample to be contaminated? 1. No shaving before obtaining the blood sample. 2. Not disinfected with alcohol before obtaining the blood sample. 3. No hand washing before obtaining the blood sample. 4. No wai�ng for alcohol or hands to dry completely before obtaining the blood sample. 5.
  • Page 34 b. The meter is off in a li�le power. In this case, the ba�eries are changed. Therefore, the year, month, and day are s�ll the latest. The �me (minutes and seconds) has to be reset a�er boo�ng the meter. c. Assuming that the ba�eries were run out one week ago, and the meter can not be turned on now. At this �me, if you replace the new ba�eries and turn it on, all �mes need to be reset.
  • Page 35 Why does not the meter need control solu�on? The meter had been corrected before shipment. No need control solu�on to correct again. Why the meter is not turned on a�er I insert the test strip or code chip? a. The test strip or code chip is not completely inserted into the test strip port; b.
  • Page 36: Troubleshoo�Ng

    Trouble shoo�ng Other problems which may occur Ac�on A test strip has not been inserted into the Review the instruc�ons and re-insert a test meter properly. strip correctly. Defec�ve test strip. Replace with a new test strip. A test strip remains in the test port for more Review the instruc�ons and re-insert a test than 2 minutes before tes�ng.
  • Page 37: Specifica�Ons

    Specifica�ons PB111 Veterinary -35-...
  • Page 38: Index Of Symbols

    Index of Symbols References -36-...
  • Page 39 Customer Service +1 (678) 829-7256 support@iauvon.com h�ps://www.iauvon.com 703 Room,7F, #153 Zhonghuicai Building Donghuan 1th Rd. Longhua St, Longhua New District Shenzhen Guangdong, CN 518000 DSW(CS)-SMS-V1.0-210105...