dSCR (Digital satellite cable router) multiswitch SRM522
Product description
Cascadable single cable wideband multiswitch SRM522 is intended for the distribution of satellite and terrestrial signals
for up to 32 satellite tuners or receivers on each output.
The multiswitch has 4 passive wideband SAT IF (for connecting 2 Wideband LNBs) and 1 Terrestrial TV passive trunk
lines, 1 pair subscribers outputs (2 outputs) and 1 signal processor and 4 x DC power modes for convenient DC powering
options (see chapter „Installation instructions").
The device ensures an independent access for every subscriber to any SAT IF or Terrestrial TV trunk line.
This multiswitch automatically detects SCR/dSCR mode or legacy format from the receiver. The dSCR switch also feature
fully automatic level control, negating the need for any gain or level adjustments in most installations. It's built into a zinc alloy
die cast housing for extreme interference immunity. The housing of multiswitch meets more stringent screening requirements
according to EN50083-2, class A.
Control according to EN50494/EN50607 (SCR/dSCR) as well as Legacy (+13 V/+18 V/22 kHz) commands.
Safety instructions
Installation of the multiswitch must be done according IEC60728-11 and national safety standards.
The multiswitch is powered from the stabilized power supply +20 V. This voltage is not dangerous to life.
External power supply must have a short circuit protection.
Any repairs must be made by qualified personnel.
To avoid damaging of the multiswitch do not connect the supply voltage until all cables have been connected correctly.
The device shall be mounted in vertical possition with RF input connectors on the top side on a wall or other nonflamable
surface.
The multiswitch must be fixed with steel screws Ø 4-4.5 mm. The screws are not included in a package.
Do not expose multiswitches to moisture or splashing water and make sure no objects filled with liquids, such as vases,
are placed near or on the unit.
Avoid placing the multiswitch next to central heating components or direct sunlight and in areas of high humidity.
No naked flame sources, such as lighted candles, should be placed on multiswitch.
If the multiswitch has been kept in cold conditions for a long time, keep it in warm room no less than 2 hours before powering.
The ventilation should not be impeded by covering the multiswitch with items, such as newspapers, table-cloths, curtains.
The mains socket of external power supply must be easily accessible
IMPORTANT WARNINGS!
Before connecting any products to a system, it is essential to make sure the system power supply is switched off. Avoid
short-circuit or overload of any power supply. Never "HOT-SWAP" any system components as this may result in damage to
the newly introduced or existing components.
The multiswitch is intended only for indoor installation or installation in a suitable weatherproof outdoor cabinet (in this
case ensure good ventilation conditions). This multiswitch must not come into contact with moisture or be installed in areas
of high humidity or heat.
It's suitable for moderate and tropical climates.
Always mount the multiswitch securely to a wall or bulkhead panel so it cannot hang or swing on its coaxial cables as this
may strain the internal circuit board and components.
Always connect all of the coaxial cables to the multiswitch before connecting the power. This unit is not designed to be
"HOT-SWAPPED" or connected to a live system.
Always be sure that connecting cables shield and multiswitch functional grounding clamp have common potential before
powering the system. Floating voltages can be created in an un-earthed system which may cause damage and can be dangerous.
Momentary short-circuit of any cables may be enough to damage the sensitive electronics within the multiswitch or the
connected system.
Always allow plenty of ventilation around the multiswitch and do not allow it to be covered with materials such as loft insulation.
We recommend at least 5 cm of airspace around the multiswitch. Digital products can get hot to the touch and require a
flow of air to avoid overheating.
SRM522 multiswitch is designed work with Ku band Wideband LNBs or Ku band Quattro LNBs (see chapter „Configuration").
LNB's and other system equipment connected to the multiswitch H SAT A and H SAT B trunks inputs/outputs are powered
from the same power supply as the multiswitch.
To avoid damage not covered by the manufacturer's warranty DO NOT EXCEED MAX. CURRENTS.
See "Technical characteristics" for max. currents for external equipment.
This product complies with the relevant clauses of the European Directive 2002/96/EC. The unit must be recycled
or discarded according to applicable local and national regulations.
Equipment intended for indoor usage only.
Functional grounding. Connect to the main potential equalization.
This product is in accordance to following norms of EU: EMC norm EN50083-2, safety norm EN60065,
RoHS norm EN50581.
This product is in accordance with Custom Union Technical Regulations: "Electromagnetic compatibility of
technical equipment" CU TR 020/2011, "On safety of low-voltage equipment" CU TR 004/2011.
This product is in accordance with safety standard AS/NZS 60065 and EMC standards of Australia.
1
EN
RU
IT
EN
User Manual
Need help?
Do you have a question about the SRM522 and is the answer not in the manual?
Questions and answers