You Are resPonsiBLe For DAMAGe to Your unit iF returneD iMProPerLY PAcKeD.
model
top
number
cutout
sGDi-1 . . . . . 23 3/8˝ x 16 3/8˝ . . . . . 5˝ x 8˝ . . . . . . . . . 36˝
sGDi-2 . . . . . 23 3/8˝ x 30 3/8˝ . . . . . 5˝ x 17˝ . . . . . . . . 24˝
sGDi-3 . . . . . 23 3/8˝ x 44 3/8˝ . . . . . 5˝ x 17˝ . . . . . . . . 24˝
sGDi-4 . . . . . 23 3/8˝ x 57 3/8˝ . . . . . 5˝ x 33 7/8˝ . . . . . 24˝
sGDi-5 . . . . . 23 3/8˝ x 71 3/8˝ . . . . . 5˝ x 33 7/8˝ . . . . . 24˝
sGDi-6 . . . . . 23 3/8˝ x 85 3/8˝ . . . . . 5˝ x 33 7/8˝ . . . . . 24˝
** Denotes minimum installation spacing from
cutouts to vertical cabinet walls per uL listing.
figure 1
eagle Foodservice equipment, eagle Mhc, specFAB, and retail Display are divisions of eagle Group. ©2018 by the eagle Group
INSTALLATION/OperATINg INSTrUCTIONS
insPect contents iMMeDiAteLY AnD FiLe cLAiM With DeLiVerinG cArrier
For AnY DAMAGe. SAVe YOUr BOX AND ALL pACKINg MATerIALS.
control
umbilical
cutout
length
Installation must meet local electrical and plumbing codes. Installation
must allow access for service. Unit shall be accessible for servicing
from the bottom.
1)
Cut holes as required in counter top and front panel. See chart for cut out sizes.
See figure 1 for cutout positioning.
2)
Remove screws holding control panel to box and remove control panel to expose field-
wiring terminals.
3)
Apply a bead of NSF listed silicone adhesive to underside of top flange. Pass control box
through top opening and work through cutout in front panel. Seat unit to counter top.
4)
From underneath insert a long, flat head screwdriver into the slots in the locking angles.
Twist clockwise 120˚ to lock unit securely to top.
5)
Install control box securely in front panel cutout with #8 sheet metal screws in top and
bottom flanges.
6)
Make electrical connections at terminal block as required. Connect unit to dedicated
electrical circuit with properly sized circuit breaker that meets the requirements of
NEC Article 422 and any local electrical codes. See unit model/serial for electrical
ratings. Replace control panel and attach knobs.
Note: All units are shipped from the factory wired for single-phase operation; all but the
single-well units are field-convertible for three-phase operation, see wiring diagram
for details.
7)
A drain manifold with ball valve is provided on all units with drains. Location of the valve
is left to the discretion of the installer*. Install provided pipe plug on end opposite ball
valve. Use of a suitable pipe-sealing compound is recommended. When tightening
connections, back up manifold fittings with a wrench to prevent damage to the manifold.
*on units with AutoFill
• 100 Industrial Boulevard, Clayton, Delaware 19938-8903 U.S. . • www.eaglegrp.com
• Phone: 302/653-3000 • (Foodservice) 800/441-8440 • (MHC/Retail) 800/637-5100
• Fax: 302/653-2065
SGDI Drop-Ins
CAUTION
replacement parts List
part #
334567 . . . . . . . . . . . element 1600W @ 240V
334567 . . . . . . . . . . . element 1200W @ 208V
334571 . . . . . . . . . . . element 1200W @ 240V
334568 . . . . . . . . . . . element 1200W @ 120V
302353 . . . . . . . . . . . Light indicator
309750 . . . . . . . . . . . thermostatic control
301986 . . . . . . . . . . . control Knob
Parts are the same for all model numbers, quantities will vary.
replacement parts List— AutoFill
337968 . . . . . . . . . . . AutoFill
349784 . . . . . . . . . . . AutoFill
338518 . . . . . . . . . . . solenoid Valve @ 120V
349785 . . . . . . . . . . . solenoid Valve @ 208/240V
338390 . . . . . . . . . . . AutoFill
338473 . . . . . . . . . . . AutoFill
Water system, the ball valve will be located on the left end.
®
description
®
Water System
®
controller @ 120V
®
controller @ 208/240V
®
switch
reservoir
®
(continued on Page 2)
eG9887 revised 11/18

Advertisement

loading

Summary of Contents for Eagle Group SGDI-1 Series

  • Page 1 • 100 Industrial Boulevard, Clayton, Delaware 19938-8903 U.S. . • www.eaglegrp.com • Phone: 302/653-3000 • (Foodservice) 800/441-8440 • (MHC/Retail) 800/637-5100 • Fax: 302/653-2065 eagle Foodservice equipment, eagle Mhc, specFAB, and retail Display are divisions of eagle Group. ©2018 by the eagle Group...
  • Page 2 SGDI Drop-Ins WIrINg DIAgrAMS FOr eLeCTrICIANS Single-Well Volts Watts Amperage 1200 10.00 4.33 4.33 1200 5.00 5.00 208* 1200 6.00 6.00 240* 1600 7.00 7.00 A = element B = Pilot Light c = thermostatic control Please see “replacement Parts List” on front page for part numbers.
  • Page 3 SGDI Drop-Ins WIrINg DIAgrAMS FOr eLeCTrICIANS Five-Well single Phase Amperage 3-Phase Amperage Volts Watts Volts Watts 1200 1200 21.60 21.60 15.00 11.50 11.20 1200 25.00 25.00 1200 17.30 13.30 13.00 208* 1200 29.00 29.00 208* 1200 20.00 15.30 15.00 240* 1600 33.50 33.50 240*...
  • Page 4 • 100 Industrial Boulevard, Clayton, Delaware 19938-8903 U.S. . • www.eaglegrp.com • Phone: 302/653-3000 • (Foodservice) 800/441-8440 • (MHC/Retail) 800/637-5100 • Fax: 302/653-2065 eagle Foodservice equipment, eagle Mhc, specFAB, and retail Display are divisions of eagle Group. ©2018 by the eagle Group...