Air angle cut-off tool long reach

Advertisement

fig. 1
4.
OPERATING INSTRUCTIONS
WARNING! Ensure that you read, understand and
apply the safety instructions before use.
4.1.
Assembly
4.1.1. To attach the cutting disc you will need the two spanners
provided, one to hold the spindle and the other to loosen/
tighten the flange nut.
4.1.2. To put on a cutting disc hold the spindle with one
spanner and place the disc over the spindle. Screw the flange nut on by hand ensuring the raised portion of
the nut faces the disc and enters the hole in it's centre. Tighten down the flange nut with the spanner provided.
4.1.3. Connect air supply to the cut-off tool and push up the safety catch, then squeeze the control valve lever
to check that the tool is working correctly.
4.2.
Operating
DO NOT apply excessive pressure, let the cut-off tool do the work for you. Start the tool and bring the disc
to the surface to be cut evenly and slowly. Remove the cutting disc from the work surface before
stopping the tool. Regularly check the condition of the disc and always change if worn, cracked or
otherwise damaged.
DO NOT run the tool away from the workpiece for extended periods as this will shorten the life of the bearings.
WARNING! Use only discs with speed ratings equal to, or higher than, the speed rating of the tool.
5.
MAINTENANCE
WARNING! Disconnect the tool from air supply before changing the disc, servicing or performing
maintenance. Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be
dangerous and will invalidate the warranty.
5.1.
Lubricate the grinder daily with a few drops of good grade air tool oil, such as Sealey ATO/500 or
ATO/1000, dripped into the air inlet before use or dispensed automatically through an air system oiler,
such as Sealey model SA106L or SA2001/L.
5.2.
Clean the tool after use and change the disc when worn or damaged.
5.3.
Loss of power or erratic action may be due to the following:
a) Excessive drain on the air supply. Moisture or restriction in the air line. Incorrect size or type of hose
connectors. To remedy check the air supply and follow instructions in Section 3.
b) Grit or gum deposits in the tool may also reduce performance. Flush the tool with gum solvent
oil or an equal mixture of SAE No 10 oil and kerosene. Allow to dry before use.
If you continue to experience problems, contact your local Sealey service agent.
5.4.
When not in use, disconnect from air supply, clean tool and store in a safe, dry, childproof location.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
fig. 2
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
Original Language Version
www.sealey.co.uk
01284 757500
Web
sales@sealey.co.uk
01284 703534
email
SA6501 Issue: 2 -
11/11/09

Advertisement

loading