Wall Oven Error Codes
Error
Message
Code
3221
RTD Open
3222
RTD Open
3311
TCO Open
3312
TCO Open
3421
MDL Operation Timeout
3422
MDL Operation Timeout
3521
Door Open In Clean
3522
Door Open In Clean
3721
Invalid MDL Switch Position
3722
Invalid MDL Switch Position
3821
Bake Bank Wiring Fault
3822
Bake Bank Wiring Fault
3921
Broil Bank Wiring Fault
3922
Broil Bank Wiring Fault
3A20
Auxiliary Bank Wiring Fault
829345 REVA
WALL OVEN ERROR CODES
Priority
Component
2
Upper/Single oven
2
Lower oven
1
Upper/Single oven
1
Lower oven
2
Upper/Single oven
2
Lower oven
2
Upper/Single oven
2
Lower oven
2
Upper/Single oven
2
Lower oven
2
Upper/Single oven
2
Lower oven
2
Upper/Single oven
2
Lower oven
2
61
E Series Oven
service.subzero.com
Service Instruction
1
Check the RTD circuit. Replace the RTD if
bad.
2
Replace the relay board.
1
Check the RTD circuit. Replace the RTD if
bad.
2
Replace the relay board.
1
Check the TCO circuit.
2
Replace the TCO.
1
Check the TCO circuit.
2
Replace oven TCO.
1
Check the oven door.
2
Check the MDL.
1
Check the oven door.
2
Check the MDL.
1
Check the door switch.
2
Check the MDL.
3
Check the oven door.
1
Check the door switch.
2
Check the MDL.
3
Check the oven door.
1
Check the MDL.
2
Check the oven door.
1
Check the MDL.
2
Check the oven door.
1
Check the bake element wiring.
2
Check voltage to the bake element.
3
Replace the relay board.
1
Check the bake element wiring.
2
Check voltage to the bake element.
3
Replace the relay board.
1
Check the broil element wiring.
2
Check voltage to the broil element.
3
Replace the relay board.
1
Check the broil element wiring.
2
Check voltage to the broil element.
3
Replace the relay board.
1
Check voltage to the auxiliary bank.
2
Replace the relay board.