    Table of Contents 1. VK Link ..............................1 2. Safety and Regulation ..........................2 2.1. Safety Information ........................... 3 2.2. Regulatory Information ........................4 3. Warranty..............................7 4. Product Overview ........................... 8 4.1. Package Contents ........................... 9 4.2. VK Link ............................10 4.3.
  • Page 3: Vk Link

    Radic8 VK Link - 1_en 1. VK Link Product Manual V1.0 Copyright © 2021 Radic8 Page 1 of 36...
  • Page 4: Safety And Regulation

    Your safety is of the utmost importance to us. This product manual contains information that is vital to the safe operation and maintenance of the VK Link. This manual also contains the performance data required to design appropriate, efficient airflow systems.
  • Page 5: Safety Information

    • Remove the remote control batteries if not in use for an extended period. • The VK Link may only be installed by a qualified HVAC designer or specialist. The VK Link is not intended to be installed by end users.
  • Page 6: Regulatory Information

    VK Link - 1_en 2.2. Regulatory Information Use environment: The Radic8 VK Link is intended for indoor use only. The unit must not be installed outdoors or anywhere that it will be exposed to water, rain, or the elements. Principle method: Air is purified through mechanical filtration and active decontamination utilizing PCO (photocatalytic oxidation) technology.
  • Page 7 Radic8 VK Link - 1_en Transport and Storage Symbols Acceptable upper and lower limits of atmospheric pressure for transport and storage. Acceptable upper and lower limits of relative humidity for transport and storage. To indicate correct upright position of the transport package.
  • Page 8 Disposal Consisting of steel, plastic, and rubber, the VK Link is 95% recyclable and should be disposed of in an environmentally friendly manner by a third-party recycling company. Copyright © 2021 Radic8...
  • Page 9: Warranty

    Radic8 VK Link - 1_en 3. Warranty The warranty period for this unit is the standard manufacturer’s warranty of 12 months. This warranty may be extended by prior agreement with authorized distribution partners. Please refer to your local distributor for queries related to warranty or claims.
  • Page 10: Product Overview

    4. Product Overview The VK Link is a versatile clean air component for use in any number of ventilation or air delivery applications. It can form the heart of a modern ventilation design or be integrated into existing ducting or HVAC configurations.
  • Page 11: Package Contents

    Radic8 VK Link - 1_en 4.1. Package Contents VK Link 200mm inline fan Remote control Control panel (batteries not included) 2 x C13 power cables 4 x Wall-mount brackets Product brief 4 x Ceiling-mount brackets Copyright © 2021 Radic8 Page 9 of 36...
  • Page 12: Vk Link

    Radic8 VK Link - 1_en 4.2. VK Link Pre-filter Carbon filter HEPA filter Reactor Chamber Wall-mount brackets Ceiling-mount brackets 200mm PVC reducers Copyright © 2021 Radic8 Page 10 of 36...
  • Page 13 Radic8 VK Link - 1_en AC input (via control panel) Front panel Hand screws Copyright © 2021 Radic8 Page 11 of 36...
  • Page 14: Control Panel

    Radic8 VK Link - 1_en 4.3. Control Panel Power button UV-C button Fan button Mode button UV-C indicator Copyright © 2021 Radic8 Page 12 of 36...
  • Page 15 Radic8 VK Link - 1_en UV-C replacement indicator indicator Infrared receiver sensor Display panel AC input (via mains supply) Fan output (to 200mm inline fan) UV-C output (to VK Link) Copyright © 2021 Radic8 Page 13 of 36...
  • Page 16: Installation

    It is important that the VK Link only be installed into a design created by a relevant specialist or retrofitted into an existing system by a qualified professional, taking into account all application variables, airflow dynamics, access, and safety considerations.
  • Page 17: Installation Notes

    When integrating the VK Link with conditioning systems, ensure the VK Link is installed upstream of (“before”) any cooling or heating coils. Airflow Direction The arrows on the front panel of the VK Link indicate the direction of airflow. Ensure the VK Link is oriented to match the airflow direction: Fan Direction Ensure the 200mm inline fan drives air in the direction of the airflow: Copyright ©...
  • Page 18 VK Link - 1_en Fan Position For optimum performance, install the fan downstream of (“after”) the VK Link: Fan Distance Ensure the 200mm inline fan is installed as close to the VK Link as possible: Copyright © 2021 Radic8 Page 16 of 36...
  • Page 19 Radic8 VK Link - 1_en Copyright © 2021 Radic8 Page 17 of 36...
  • Page 20: Wiring

    5.2. Wiring Before installation or use, ensure the correct mains AC voltage. The VK Link, control panel, and 200mm inline fan are connected as follows: Connect the 200mm inline fan to the control panel via the mated 4-pin communication and power cable.
  • Page 21: Operation

    ) will illuminate. Switching the Reactor Chamber on or off The VK Link’s Reactor Chamber can be switched on or off independently by pressing the UV-C button ( When the Reactor Chamber is on, the UV-C indicator ( ) is illuminated.
  • Page 22 Radic8 VK Link - 1_en Adjusting fan speed The speed of the inline fan can be adjusted by pressing the fan button ( ). This will cycle between four fan speed settings: AUTO Automatic fan speed FAN 1 Low fan speed...
  • Page 23 Radic8 VK Link - 1_en Setting the time On the control panel: 1. Press and hold the mode button ( ) for 3 seconds to enter time adjustment mode. 2. The time will appear on the display panel and the last digit will flash.
  • Page 24: Maintenance

    Maintenance should only be performed by a qualified HVAC specialist, installer, or facility maintenance contractor. Maintenance of the VK Link and replacement of consumables is essential to ensure the longevity of the device. Ensure the unit is switched off before conducting any maintenance.
  • Page 25: Cleaning The Pre-Filter

    Radic8 VK Link - 1_en 7.1. Cleaning the Pre-Filter The pre-filter should be cleaned regularly to remove buildup of trapped material and ensure optimal airflow. 1. Slide out the pre-filter. 2. Clean the pre-filter by wiping it with a dust or microfiber cloth.
  • Page 26: Replacing The Carbon And Hepa Filters

    Radic8 VK Link - 1_en 7.2. Replacing the Carbon and HEPA Filters The carbon and HEPA filters are not reusable and should be replaced every 6 months. Carbon filter 1. Slide out the used carbon filter. 2. Safely dispose of the used carbon filter (see below).
  • Page 27 Radic8 VK Link - 1_en HEPA filter 1. Slide out the used HEPA filter. 2. Safely dispose of the used HEPA filter (see below). 3. Slide in a new HEPA filter. Safe disposal of filters • After used filters have been removed, we recommend lightly misting the used filter material with an alcohol-based sanitizer.
  • Page 28: Replacing The Reactor Chamber

    1. Disconnect the Reactor Chamber power connector ( 2. Remove the 2 screws holding the Reactor Chamber brackets and earth wires to the VK Link chassis: Copyright © 2021 Radic8 Page 26 of 36...
  • Page 29 Radic8 VK Link - 1_en 3. Slide out the brackets and Reactor Chamber from the body of the unit: 4. Remove the 4 screws from each bracket and remove the brackets: Copyright © 2021 Radic8 Page 27 of 36...
  • Page 30 9. Reconnect the Reactor Chamber power connector ( 10. When safe to do so, switch on the VK Link and hold the fan button on the control panel for 10 seconds to reset the Reactor Chamber runtime to zero. This will also turn off the control panel UV-C replacement indicator.
  • Page 31: Troubleshooting

    Radic8 VK Link - 1_en 7.4. Troubleshooting Control panel display errors: The temperature of the internal PCB has exceeded 80°C. Switch the unit off. The fan motor is not functioning correctly. Switch the unit off. Please contact your local distributor if any of the above errors are displayed.
  • Page 32: Specifications

    Radic8 VK Link - 1_en 8. Specifications Radic8 reserves the right to make changes to the design and specifications of the VK Link without prior notice. Firmware version 1.1 Model VK Link Coverage* Net weight 14.1kg (31lbs) Dimensions (mm) 365 × 330 × 528 Dimensions (in) 14.37 ×...
  • Page 33 Radic8 VK Link - 1_en Operation and transport conditions: Temperature 10–45°C Relative humidity (non-condensing) 30–80% Pressure 80–106kPa Copyright © 2021 Radic8 Page 31 of 36...
  • Page 34: Performance Data

    Radic8 VK Link - 1_en 8.1. Performance Data VK Link efficiency Filter efficiency 99.995% Airflow 220–270 CFM Filter face area 0.084 m Static pressure drop (max fan speed) 230Pa 200mm inline fan performance Model VTRONIC W200-1 Weight 4.1kg (9lbs) Dimensions (mm) 350 ×...
  • Page 35 Radic8 VK Link - 1_en 200mm inline fan curves Copyright © 2021 Radic8 Page 33 of 36...
  • Page 36: Dimensions

    Radic8 VK Link - 1_en 8.2. Dimensions All dimensions are specified in millimeters: VK Link 200mm inline fan Copyright © 2021 Radic8 Page 34 of 36...
  • Page 37 Radic8 VK Link - 1_en Control panel Copyright © 2021 Radic8 Page 35 of 36...
  • Page 38: Support

    Radic8 VK Link - 1_en 9. Support For VK Link hardware support, please contact your local VK Link distributor. Radic8 PTE Ltd 7 Temasek Boulevard #12-07 Suntec Tower One Singapore 038987 info@radic8.com You can find the model and serial number on the back of your device.

Table of Contents