USER MANUAL
CDI-H27 AD BLUE PUMP
Before Installing And Use Please Read The Instruction Manual Carefully

Advertisement

Table of Contents
loading

Summary of Contents for AdBlue CDI-H27

  • Page 1 USER MANUAL CDI-H27 AD BLUE PUMP Before Installing And Use Please Read The Instruction Manual Carefully...
  • Page 2 CDI-H27 AD BLUE PUMP DESCRIPTION SECTION SAFETY INSTRUCTIONS APPLICATION INSTALLATION ELECTRICAL CONNECTION OPERATION MAINTENANCE TROUBLE SHOOTING DISASSEMBLY AND DISPOSAL DIMENSIONAL DRAWING WARRANTY SECTION 1 SAFETY INSTRUCTIONS This instruction manual contains essential information that must be observed during installation, operation and servicing. It is therefore important that the installer and the responsible technician/operator read this instruction manual before the equipment is installed and put into operation.
  • Page 3 SAFETY INSTRUCTIONS FOR INSTALLATION, INSPECTION AND MAINTENANCE WORKS As a basic principle, works may only be carried out to the equipment when it is shut down. Pumps or plant that convey harmful substances must be decontaminated. All safety and protection components must be re-fitted and/or made operational immediately after the works have been completed.
  • Page 4: Section 2 Application

    SECTION 2 APPLICATION The CDI-H27 pump is a five chamber positive displacement diaphragm pump. Designed for pumping AD Blue (AUS32-DEF-ADBLUE) with no solid suspended particles, fibres or abrasive materials. NOT FOR PUMPING PETROL! DANGER Never use the pump for flammable and/or explosive liquids Improper use of the pump can lead to physical injury and/or material damage.
  • Page 5: Section 3 Installation

    SECTION 3 INSTALLATION Install the pump on a flat surface and secure to prevent movement during start-up and operation, ensuring that there are no obstructions to the regular flow of cooling air delivered by the motor fan. Clean the pump prior to installation if left unused for prolonged periods of time Ensure that the installation site is sufficiently sized to enable assembly of the pump on the system and future maintenance operations.
  • Page 6 Correct pump installation is essential to ensure priming Position the pump in the vicinity of the well or tank to ensure that the suction pipe is as short as possible. In this way, the priming time is reduced, above all in the case of large differences in height between the liquid and suction point.
  • Page 7: Section 4 Electrical Connection

    SECTION 4 ELECTRICAL CONNECTION DANGER - ELECTRIC SHOCK RISK Ensure that the rated voltage and frequency correspond to those of the specifications of the mains power available. The electrical connection must be made according to current local standards. Before any intervention on the pump - 230v pumps, disconnect the electrical mains. Low voltage pumps - Disconnect from the low voltage power source.
  • Page 8: Section 5 Operation

    SECTION 5 OPERATION ATTENTION The pump must never be operated with the shut off valve on the delivery side closed. The discharge valve must be opened as soon as the pump has been started up, to prevent damage to the latter by an excessive increase in liquid temperature Use the electric pump according to the performance specifications as stated on the data plate.
  • Page 9: Section 6 Maintenance

    SECTION 6 MAINTENANCE DANGER - ELECTRIC SHOCK RISK Before any intervention on the pump, disconnect the electrical power supply. Ensure that the electrical power supply cannot be restored inadvertently ATTENTION Refer to safety instructions In normal conditions, the electric pumps do not require any scheduled maintenance. With a view to prevention of possible faults, it is recommended to periodically check the pressure delivered and current absorption.
  • Page 10: Section 7 Troubleshooting Guide

    SECTION 7 TROUBLESHOOTING GUIDE ATTENTION Refer to safety instructions THE PUMP DOES NOT WORK No power supply - Turn off the switch and check that no electrical connections are loose or defective Check the mains voltage (230v) Check the DC low voltage (12v / 24v) Fuse blown - Check that the cables and relative connections are not defective and replace the fuse if necessary The 230v single phase motor thermal cut out has tripped this is reset automatically...
  • Page 11: Disassembly And Disposal

    This product or any part of the latter must be disposed of in accordance with local standards using the public or private waste collection authorities as required SECTION 9 DIMENSIONAL DRAWINGS CDI-H27 230v CDI-H27 12v & 24v...
  • Page 12: Warranty

    SECTION 10 WARRANTY Conditions of Warranty Terms Products are covered by Warranty relating to manufacturing defect or failing and/or those of the material used. The components subject to fair wear and tear, such as bearings, seal housing bushes, seals and o rings are not covered under the manufactures warranty.