Beko BEKOMAT 16i CO Translation Of Original Installation And Operation Manual

Table of Contents

Advertisement

Quick Links

EN
Original installation and operation manual
BEKOMAT
16i CO
®
> BM16iCO
01-4287

Advertisement

Table of Contents
loading

Summary of Contents for Beko BEKOMAT 16i CO

  • Page 1 Original installation and operation manual BEKOMAT 16i CO ® > BM16iCO 01-4287...
  • Page 2: Table Of Contents

    BEKOMAT ® 16i CO Original installation and operation manual Table of contents 1. Notes about the documentation .....................5 1.1 Contact ............................5 1.2 Information about this installation and operation manual .............5 2. Safety ..............................6 2.1 Use .............................6 2.1.1 Intended use ............................6 2.1.2 Reasonably foreseeable inappropriate use .................
  • Page 3 Original installation and operation manual BEKOMAT 16i CO ® 4. Technical data ..........................25 4.1 Operating parameters ......................25 4.2 Storage and transportation parameters ................26 4.3 Materials ..........................26 4.4 Dimensions BEKOMAT 16i CO .................... 26 ® 4.5 Screw fastening torques BEKOMAT 16i CO ...............
  • Page 4 BEKOMAT ® 16i CO Original installation and operation manual Table of contents 11. Consumables, accessories and spare parts ................59 11.1 Order information ........................ 59 11.2 Accessories ........................... 59 11.3 Spare parts..........................60 12. Decommissioning ........................65 12.1 Warning notices ........................65 12.2 Decommissioning work .......................
  • Page 5: Notes About The Documentation

    This documentation contains all the necessary steps for use and operation of the product and the accessories. 1.1 Contact Manufacturer Customer service and tools BEKO TECHNOLOGIES GmbH BEKO TECHNOLOGIES GmbH Im Taubental 7 | 41468 Neuss Im Taubental 7 | 41468 Neuss Tel.
  • Page 6: Safety

    • Only combine the product and accessories with the products and components named and recommended by BEKO TECHNOLOGIES in the manual. • Adhere to the prescribed maintenance schedule. Before using the product and the accessories, the operating company must make sure that all conditions and prerequisites for intended use are given.
  • Page 7: Reasonably Foreseeable Inappropriate Use

    Original installation and operation manual BEKOMAT 16i CO ® 2.1.2 Reasonably foreseeable inappropriate use Reasonably foreseeable inappropriate use is deemed to have occurred if the product or the accessories are used in any other way than that described in the chapter "Intended use". Reasonably foreseeable inappropriate use includes the use of the product or the accessories in a manner not intended by the manufacturer or supplier but which may result from foreseeable human behaviour.
  • Page 8: Target Group And Personnel

    BEKOMAT ® 16i CO Original installation and operation manual 2.3 Target group and personnel This manual addresses the personnel listed below who are involved with work on the product or the accessories. INFORMATION Personnel requirements! The personnel may not execute any actions on the product or the accessories when they are under the influence of drugs, medications, alcohol or other substances that may impair their ...
  • Page 9: Explanation Of The Safety Symbols Used

    Original installation and operation manual BEKOMAT 16i CO ® 2.4 Explanation of the safety symbols used The symbols used below indicate safety-relevant and important information which must be adhered to when handling the product and to ensure safe and optimum operation. Symbol Description / explanation General warning symbol (danger, warning, caution)
  • Page 10: Safety Instructions And Warning Notices

    BEKOMAT ® 16i CO Original installation and operation manual 2.5 Safety instructions and warning notices This chapter provides an overview of all the important safety aspects for personal protection as well as for the safe and problem-free operation of the product and accessories. The following chapters list the dangers posed by this product and the accessories even with intended use.
  • Page 11: Electric Voltage

    Original installation and operation manual BEKOMAT 16i CO ® 2.5.3 Electric voltage Contact with live components may result in serious personal injuries or death. To ensure the safe handling of live components, observe the following points: • Set up a safety area around the working area during all installation and repair work. •...
  • Page 12: Maintenance

    • Dispose of electrical and electronic components through a specialist waste disposal company or return to BEKO TECHNOLOGIES. 2.5.7 Handling hazardous substances Contact with condensate containing substances which endanger health and the environment can pose a health hazard, causing irritation and/or damage to the eyes, skin and mucous membranes. In addition, polluted condensate must be ...
  • Page 13: Use Of Spare Parts, Accessories Or Materials

    Original installation and operation manual BEKOMAT 16i CO ® 2.5.8 Use of spare parts, accessories or materials The use of incorrect spare parts, accessories or materials, as well as auxiliary and operating materials, may result in death or serious injury. Malfunction and device failure as well as material damage can occur. •...
  • Page 14: Product Information

    BEKOMAT ® 16i CO Original installation and operation manual 3. Product information 3.1 Exploded view BEKOMAT 16i CO ® Item Description / explanation Item Description / explanation Screw M3 x 10 [29] Solenoid coil Top cover [30] O-ring 5.5 x 1.5 mm Dust protection pane [31] Control air cover...
  • Page 15 Original installation and operation manual BEKOMAT 16i CO ® 55 56 51 50 15 | 76...
  • Page 16: Product Overview

    BEKOMAT ® 16i CO Original installation and operation manual 3.2 Product overview Item Description / explanation Item Description / explanation Control panel Valve unit Right cable gland Condensate inlet Left cable gland Connection for venting line Condensate discharge 16 | 76...
  • Page 17: Function Description

    Original installation and operation manual BEKOMAT 16i CO ® 3.3 Function description Illustration Description / explanation The condensate flows via the condensate  inlet [F] into the BEKOMAT and collects in ® the housing [18]. The filling level in the housing [18] is continuously monitored by a capacitive sensor in the sensor tube [44]. Once the condensate has reached the maximum fill level, the pilot valve [X1] is activated using the controller.
  • Page 18: Modbus Function

    BEKOMAT ® 16i CO Original installation and operation manual 3.4 Modbus function The BEKOMAT has an integrated Modbus which can be used to read out the operating parameters and device ® information. The BEKOMAT is operated using the client-server system with operating mode Modbus-RTU. ®...
  • Page 19: Read Input Registers (0X04)

    Original installation and operation manual BEKOMAT 16i CO ® 3.4.3.1 Read Input Registers (0x04) Modbus Contents Description / explanation Data type address 1116 Main Timer Hi-Word Operating hours counter [h] 1117 Main Timer Lo-Word 1102 Main Counter Hi-Word Counter for switching cycles 1103 Main Counter Lo-Word 1540...
  • Page 20: Read Device Identification (0X2B / 0X0E)

    Item name Object Description / explanation Examples Format (Modbus specification) 0x00 VendorName Manufacturer BEKO TECHNOLOGIES ASCII BEKO material number circuit 0x01 ProductCode 4023034 ASCII board 0x02 MajorMinorRevision Software version numbers* APP V2.3.0 BBS V3.4.0 CFG V1.0.0 ASCII http://www.beko-technologies. 0x03...
  • Page 21: Changing Interface Parameters

    3.4.3.3 Changing interface parameters INFORMATION BEKO TECHNOLOGIES configuration tools! BEKO TECHNOLOGIES recommends using the Software Integrator to change the interface parameters. The software can be downloaded from the BEKO TECHNOLOGIES homepage (see “1.1 Contact” on Page 5). For connection to a PC, BEKO TECHNOLOGIES recommends using the Integrator Hardware Kit (for ordering information see chapter “11.2 Accessories”...
  • Page 22: Control Commands

    BEKOMAT ® 16i CO Original installation and operation manual 3.4.3.4 Control commands The forwarding of control commands to the product is described below. Control-Holding-Register (Modbus Specification) Control command Description / explanation Command Hex. Dec. Value All the LEDs of a certain device flash at  Beacon on 0x1770 6000 0x0001 the same time to identify this device.
  • Page 23: Type Plate

    If you contact the manufacturer or supplier, always have this data ready for system identification. BM16i +1°...+60°C / 34°...140°F 12345678 0,8-16 bar(g) / 12-230 psi(g) 4046928 IP 65 TYPE13 24 VDC ±10% /<8W BEKO TECHNOLOGIES GMBH IM TAUBENTAL 7 D-41468 NEUSS 12345678 Made in Germany Example illustration Item Description / explanation Product name...
  • Page 24: Scope Of Delivery

    BEKOMAT ® 16i CO Original installation and operation manual 3.6 Scope of delivery The table below shows the scope of delivery of the BEKOMAT ® Illustration Description / explanation BEKOMAT 16i CO ® Original installation and operation manual Original Installations- und Betriebsanleitung BEKOMAT 16i CO ®...
  • Page 25: Technical Data

    Original installation and operation manual BEKOMAT 16i CO ® 4. Technical data 4.1 Operating parameters BEKOMAT 16i CO ® Ambient relative humidity 10 … 80 %, without condensation 2000 m Maximum operating height 2187.23 yd 0.8 … 16 bar(g) Minimum / maximum operating pressure 12 …...
  • Page 26: Storage And Transportation Parameters

    BEKOMAT ® 16i CO Original installation and operation manual 4.2 Storage and transportation parameters BEKOMAT 16i CO ® Minimum / maximum temperature,  +1 … +60 °C storage and transportation +34 … +140 °F 4.3 Materials BEKOMAT 16i CO ® Housing Aluminium, hardcoated Membrane 4.4 Dimensions BEKOMAT 16i CO ®...
  • Page 27: Screw Fastening Torques Bekomat ® 16I Co

    Original installation and operation manual BEKOMAT 16i CO ® 4.5 Screw fastening torques BEKOMAT 16i CO ® Item Description / explanation Fastening torques [Z1] Screws, control-air cover 1.5 Nm +0.5 Nm (1.11 ft-lb +0.37 ft-lb) Screw, solenoid valve connector 1.0 Nm +0.2 Nm (0.74 ft-lb +0.15 ft-lb) [Z2] [Z3] Screws, membrane cap valve unit...
  • Page 28: Installation Dimensions

    BEKOMAT ® 16i CO Original installation and operation manual 4.6 Installation dimensions Illustration Description / explanation Allow sufficient assembly space above the top cover at the  place of installation so that the LEDs are visible and the TEST button can be pressed. 4.7 Terminal diagram power control board Illustration GND / 0V RS485 - B RS485 - A...
  • Page 29: Transport And Storage

    5.1 Transport After transporting and removing the packaging material, inspect the product for possible transport damage. If you find  such damage, notify the carrier company, BEKO TECHNOLOGIES or one of its agents immediately. Transport the product as follows: • Only transport the product in its original packaging.
  • Page 30: Assembly

    BEKOMAT ® 16i CO Original installation and operation manual 6. Assembly 6.1 Warning notices DANGER Use of incorrect spare parts, accessories or materials! The use of incorrect spare parts, accessories or materials, as well as auxiliary and operating materials, may result in death or serious injury. Malfunction and device failure as well as material damage can occur.
  • Page 31: Assembly Conditions

    Original installation and operation manual BEKOMAT 16i CO ® 6.2 Assembly conditions Wrong Right Description / explanation Minimum installation height • The inlet height must be located lower than the lowest point of the collecting tank, at least 185 mm (7.28 in). (inch) >...
  • Page 32 BEKOMAT ® 16i CO Original installation and operation manual Wrong Right Description / explanation Drain line version • Do not use shut-off valves in the drain line. • Only connect the BEKOMAT to the drain ® line using a hose. 0 The hose compensates for assembly tolerances, vibrations and thermal expansion.
  • Page 33: Assembly Work

    Original installation and operation manual BEKOMAT 16i CO ® Wrong Right Description / explanation Ensure venting • If the slope in the inflow is not sufficient or  there are other problems with the inflow,  install a venting line. Discharge from pressurised pipes • Divert the flow of gas to provide a deflecting  surface to discharge the fluid components in  the gas. 6.3 Assembly work For assembly work to be carried out, the following prerequisites must be fulfilled and the preparatory tasks must have  been completed. Prerequisites Tools Material Protective equipment •...
  • Page 34 BEKOMAT ® 16i CO Original installation and operation manual Assembly work Illustration Description / explanation 4. Remove the plugs [21, 35, 42] at the inlet connection [F], drain connection [D] and the connection for the venting line [G]. Recommendation: For product maintenance, install the shut-off  valves [X3, X4] in the venting line [X2] and in the condensate inlet line [X5].
  • Page 35 Original installation and operation manual BEKOMAT 16i CO ® Assembly work Illustration Description / explanation 6. For the condensate discharge, fit the hose [X6] provided to the drain connection [D] and use a hose clamp for fixation. 7. Connect the other end of the hose [X6] with the condensate discharge line [X7].
  • Page 36: Electrical Installation

    BEKOMAT ® 16i CO Original installation and operation manual 7. Electrical installation 7.1 Warning notices DANGER Use of incorrect spare parts, accessories or materials! The use of incorrect spare parts, accessories or materials, as well as auxiliary and operating materials, may result in death or serious injury. Malfunction and device failure as well as material damage can occur.
  • Page 37: Connection Work

    Original installation and operation manual BEKOMAT 16i CO ® NOTE Electromagnetic interference! Electromagnetic faults caused by high-voltage cables, switchgears and high-frequency switching components, in particular speed-controlled and frequency-controlled drives (VSD/ VFD) can interfere with the operation of electronic devices and communication between electronic devices. • Mount electronic devices far away from high voltage cables, switching systems and high- frequency switching components.
  • Page 38: Single Device Connection

    BEKOMAT ® 16i CO Original installation and operation manual 7.2.1 Single device connection Connection work - single device Illustration Description / explanation 1. Loosen the 4 screws [1]. 2. Lift the top cover [2]. 3. Raise the top cover [1] slightly and pull the terminal clamp [10] off.
  • Page 39 Original installation and operation manual BEKOMAT 16i CO ® Connection work - single device Illustration Description / explanation Connection cable [X8] 8. Connect the connection cable [X8] according to the terminal diagram “4.7 Terminal diagram power control board” on Page 28. 9.
  • Page 40: Connecting Multiple Modbus Devices (Series Connection)

    BEKOMAT ® 16i CO Original installation and operation manual 7.2.2 Connecting multiple Modbus devices (series connection) Connection work - series connection Illustration Description / explanation 1. Loosen the 4 screws [1]. 2. Lift the top cover [2]. 3. Raise the top cover [2] slightly and pull the terminal clamp [10] off.
  • Page 41 Original installation and operation manual BEKOMAT 16i CO ® Connection work - series connection Illustration Description / explanation 7. Fit the cable gland components [4, 5, 6] over the connection cable [X8] and insert the connection cable [X9]. 8. Insert the connection cable [X9] into the left cable gland [C].
  • Page 42: Commissioning

    BEKOMAT ® 16i CO Original installation and operation manual 8. Commissioning 8.1 Warning notices DANGER Operation outside the permissible limit range! Operation of the product and accessories outside the permissible limits and operating parameters, unauthorised intervention and modifications may result in death or serious  injury. • Adhere to the limits and operating parameters specified on the type plate and in the  manual. • Check whether the operating parameters have been amended or restricted by the use of accessories.
  • Page 43: Commissioning Work

    Original installation and operation manual BEKOMAT 16i CO ® 8.2 Commissioning work Illustration Description / explanation 1. Connect the voltage supply. 0 The BEKOMAT carries out the power-on self-test. ® 2. Slowly pressurise the system (e.g. by slowly opening the recommended shut-off valve [X4] in the condensate inlet line [X5]).
  • Page 44: Operation

    BEKOMAT ® 16i CO Original installation and operation manual 9. Operation 9.1 Warning notices DANGER Operation outside the permissible limit range! Operation of the product and accessories outside the permissible limits and operating parameters, unauthorised intervention and modifications may result in death or serious  injury. • Adhere to the limits and operating parameters specified on the type plate and in the  manual. • Adhere to the assembly conditions and ambient conditions. •...
  • Page 45: Operating States

    Original installation and operation manual BEKOMAT 16i CO ® 9.2 Operating states Illustration Description / explanation Disconnected • All LEDs are off. Switch on / power-on self-test • All LEDs are on for 1 second. • The BEKOMAT carries out a diagnosis of ®...
  • Page 46 BEKOMAT ® 16i CO Original installation and operation manual Illustration Description / explanation Discharge procedure (TEST button pressed briefly) • The red ALARM LED is off. • The green VALVE LED is on during the discharge procedure. • The green POWER LED is on. Pre-alarm (TEST button pressed >1 minute and <5 minutes) •...
  • Page 47: Maintenance

    Original installation and operation manual BEKOMAT 16i CO ® 10. Maintenance 10.1 Warning notices DANGER Pressurised system! There is a danger of death or serious personal injury resulting from contact with fast or suddenly escaping fluids or through bursting system parts. • All maintenance and repair work on the system must be carried out in the depressurised state and with the system secured against unintentional pressurisation.
  • Page 48: Maintenance Schedule

    BEKOMAT ® 16i CO Original installation and operation manual 10.2 Maintenance schedule Maintenance Interval Wear part replacement After 8760 operating hours or 1 million switching cycles*; at least annually Cleaning Annually Functional test Monthly Visual inspection Weekly Leakage test After assembly and maintenance works on the product * based on 7 bar(g) (101.5 psi(g)) and pH-neutral condensate INFORMATION Carrying out cleaning work...
  • Page 49: Wear Part Replacement

    Original installation and operation manual BEKOMAT 16i CO ® 10.3.1 Wear part replacement Wear part replacement Illustration Description / explanation 1. Loosen the screw [49] of the solenoid valve connector [50]. 2. Pull the solenoid valve connector [50] off. 3. Loosen the screws [26] from the valve unit [E]. 49 | 76...
  • Page 50 BEKOMAT ® 16i CO Original installation and operation manual Wear part replacement Illustration Description / explanation 4. Take the valve unit [E] off. 5. Loosen the screws [32] and take the valve unit apart. 50 | 76...
  • Page 51 Original installation and operation manual BEKOMAT 16i CO ® Wear part replacement Illustration Description / explanation 6. Loosen the nuts [34] with the spring washers [33] and take the housing upper part [40] off. 51 | 76...
  • Page 52 BEKOMAT ® 16i CO Original installation and operation manual Wear part replacement Illustration Description / explanation 7. Replace all the components in the set of wear parts [X]. 8. Grease the O-rings in the set of wear parts. 9. Set the housing upper part [40] in place again and screw tight using the nuts [34] and spring washers [33].
  • Page 53 Original installation and operation manual BEKOMAT 16i CO ® Wear part replacement Illustration Description / explanation 11. Re-assemble the solenoid valve as shown and tighten using the screws [32]. 12. Tighten the screws [32] with a torque of 1.5 Nm +0.5 Nm (1.11 ft-lb +0.37 ft-lb). 13.
  • Page 54: Functional Test

    BEKOMAT ® 16i CO Original installation and operation manual Wear part replacement Illustration Description / explanation 14. Screw the valve unit [E] using the screws [26]. 15. Tighten the screws [26] with a torque of 2.5 Nm +/- 0.5 Nm (1.84 ft-lb +0.37 ft-lb). 16. Fit the solenoid valve connector [50] and screw tight using the screw [49].
  • Page 55: Visual Inspection

    The leakage test is a non-destructive test method and is used to prove leak tightness in vacuum and overpressure systems. The leakage test can be carried out in different ways. BEKO TECHNOLOGIES provides no recommendations for selecting a testing process. The operating company of the pressurised system is responsible for the selection and specification of the test method to be used, which should be executed in corresponding to with valid standards and ...
  • Page 56: Cleaning

    BEKOMAT ® 16i CO Original installation and operation manual 10.3.5 Cleaning CAUTION Inappropriate cleaning and use of the wrong cleaning media! Inappropriate cleaning and the use of the wrong cleaning media may result in minor injuries as well as damage to health and damage to property. •...
  • Page 57 Original installation and operation manual BEKOMAT 16i CO ® Cleaning work Illustration Description / explanation 3. Clean the membrane seat using a cleaning brush Ø max. = 2.5 mm (0.09"). 4. Clean the guide bushings for the control-air pipe and the control-air pipe itself using a cleaning brush Ø max. = 2.5 mm (0.09").
  • Page 58 BEKOMAT ® 16i CO Original installation and operation manual Cleaning work Illustration Description / explanation 6. Wipe the membrane seat and the membrane cap down using a clean cloth without cleaning agent. 7. Clean the membrane cap using a cleaning brush Ø max. = 2.5 mm (0.09").
  • Page 59: Consumables, Accessories And Spare Parts

    Material number and designation of the accessory or spare part • Required quantity of accessories or spare parts to be delivered The contact data for the BEKO TECHNOLOGIES customer services responsible are listed in chapter “1.1 Contact” on Page 5. 11.2 Accessories...
  • Page 60: Spare Parts

    16i CO Original installation and operation manual Illustration Description Material no. Integrator Hardware Kit 4052710 The software can be downloaded from the BEKO TECHNOLOGIES Software Integrator homepage (see “1.1 Contact” on Page 5). 11.3 Spare parts Illustration Description Material no.
  • Page 61 Original installation and operation manual BEKOMAT 16i CO ® Illustration Description Material no. Membranes, 3 pieces 4002451 Valve unit 2000089 61 | 76...
  • Page 62 BEKOMAT ® 16i CO Original installation and operation manual Illustration Description Material no. Valve attachment components 2000088 (contains the marked components [X]) 62 | 76...
  • Page 63 Original installation and operation manual BEKOMAT 16i CO ® Illustration Description Material no. Set of seals 2000090 Housing main part 2000092 63 | 76...
  • Page 64 BEKOMAT ® 16i CO Original installation and operation manual Illustration Description Material no. Housing lid 2000066 Top cover 2000066 64 | 76...
  • Page 65: Decommissioning

    Original installation and operation manual BEKOMAT 16i CO ® 12. Decommissioning 12.1 Warning notices DANGER Pressurised system! There is a danger of death or serious personal injury resulting from contact with fast or suddenly escaping fluids or through bursting system parts. • All work on the system must be carried out in the depressurised state and with the system secured against unintentional pressurisation.
  • Page 66: Decommissioning Work

    BEKOMAT ® 16i CO Original installation and operation manual 12.2 Decommissioning work Illustration Description / explanation 1. Interrupt the condensate feed and close the condensate inlet line [X5]. (e.g. close the recommended shut-off valve [X4]). 2. Close the venting line [X2] (e.g. using the recommended shut-off valve [X3]). 3. Press the TEST button briefly multiple times. 0 The pressure in the BEKOMAT is reduced.
  • Page 67: Dismantling

    Original installation and operation manual BEKOMAT 16i CO ® 13. Dismantling 13.1 Warning notices DANGER Pressurised system! There is a danger of death or serious personal injury resulting from contact with fast or suddenly escaping fluids or through bursting system parts. • All work on the system must be carried out in the depressurised state and with the system secured against unintentional pressurisation.
  • Page 68: Dismantling Work

    BEKOMAT ® 16i CO Original installation and operation manual 13.2 Dismantling work For dismantling work to be carried out, the following prerequisites must be fulfilled and the preparatory tasks must have  been completed. Prerequisites Tools Material Protective equipment • Spanner or adjustable end wrench • No material necessary Always to be worn: Preparatory tasks Decommissioning has been completed. Depressurise the pressurised system or the respective system section and secure it against unintentional pressurisation.
  • Page 69: Concluding Work

    Original installation and operation manual BEKOMAT 16i CO ® Dismantling work Illustration Description / explanation 5. Remove the hose [X6] from the condensate discharge [D] and disassemble. 6. Remove the condensate inlet line [X5] and the recommended shut-off valve [X4] from the condensate inlet [F] and disassemble. 7.
  • Page 70: Disposal

    Dispose of all components, parts, operating and auxiliary materials as well as cleaning media professionally and in accordance with regional legal specifications and regulations. • Dispose of electrical and electronic components through a specialist waste disposal company or return to BEKO TECHNOLOGIES. • In case of uncertainties regarding disposal, always consult a regional waste management company.
  • Page 71: Disposal Of Operating And Auxiliary Materials

    Original installation and operation manual BEKOMAT 16i CO ® 14.2 Disposal of operating and auxiliary materials Ensure the following prerequisites are met before disposal: Preparatory tasks The BEKOMAT has been decommissioned. ® The BEKOMAT is disassembled. ® The BEKOMAT is clean and free from all media residues. ®...
  • Page 72: Troubleshooting And Fault Repair / Faq

    15. Troubleshooting and fault repair / FAQ Error or fault pattern Possible causes Troubleshooting n = ∞ • Negative power-on self-test. • Contact BEKO TECHNOLOGIES customer 0 The electronics unit is service (see “1.1 Contact” on Page 5). defective. • Read off the operating voltage on the type  plate and check it. •...
  • Page 73: Appendices

    Original installation and operation manual BEKOMAT 16i CO ® 16. Appendices 16.1 Approval certificates and declarations of conformity Symbol Description / explanation CE marking The CE marking indicates that a product fulfils all the EU directives applicable for this product and  that basic safety and health requirements were met during manufacturing of the product. The product may be sold on the European market. FCC marking The FCC marking indicates that a product fulfils the requirements of the Federal Communications ...
  • Page 74: Declaration Of Conformity

    BEKOMAT ® 16i CO Original installation and operation manual 16.2 Declaration of Conformity 74 | 76...
  • Page 75 Original installation and operation manual BEKOMAT 16i CO ® 75 | 76...
  • Page 76 Tel. +81 44 328 76 01 service.it@beko-technologies.com info@beko-technologies.jp BEKO TECHNOLOGIES S. de R.L. de C. BEKO TECHNOLOGIES CORP. BEKO Technologies, S de R.L. de C.V. 900 Great Southwest Pkwy SW Blvd. Vito Alessio Robles 4602 Bodega 10 US - Atlanta, GA 30336 Zona Industrial Tel.

This manual is also suitable for:

Bm16ico

Table of Contents