DeltaPoint Jr Installation and Operation Manual 6 GPM (22.7 LPM) Unit EMERGENCY 24 Hour Service Phone Number 877-684-0589 Effective with products having serial number 040817000 and greater, Firmware Revision 3.15 DPJMAN-1106 ROCON LLC 1755 East Nine Mile Road, Hazel Park, MI 48030...
TABLE OF CONTENTS TABLE OF CONTENTS ..........................2 PROPRIETARY NOTICE ..........................3 SPECIFICATION ............................4 DIMENSIONS ............................... 5 DeltaPoint Jr. Top View ..........................5 DeltaPoint Jr. End View ..........................6 HOW IT WORKS ............................7 INSTALLATION ............................. 8 ELECTRICAL CIRCUIT ..........................9 JUMPER SETTINGS ..........................
Publication of this information does not convey any rights of use or reproduction other than in connection with the installation, operation and maintenance of the equipment described herein. Universal Flow Monitors, Inc. and Rocon LLC reserve the right to change the information contained in this publication at any time and without prior notice.
ROCON LLC GENERAL SPECIFICATION Maximum Operating Pressure: 150 PSI (10 bar) Minimum Operating Pressure: 10 PSI of back pressure is required for the formation of vortices. Temperature Ratings: 14 F to 122 F (-10 C to 50 C) Ambient: 176 F (80 C) Maximum...
HOW IT WORKS DeltaPoint Jr. is a cooling water flow switch. It is comprised of a flow sensor, a shut-off valve, a check valve, and all the associated wiring, complete in one package. When installed in the return leg, it can detect changes in water flow due to cap loss or a break in the line, and shut off the supply/return water legs.
ROCON LLC INSTALLATION There are no upstream or downstream piping requirements to achieve proper operation. Refer to page 22 to review requested water flow test using 90 degree elbow. The unit should be installed on the fence line for best results. The unit can be installed in any position as long as good piping installation requirements are adhered to.
ROCON LLC JUMPER SETTINGS DeltaPoint Jr - JUMPERS JP3 JP4 DeltaPoint Jr Interface Board Jumper Part # 7548 VOLTAGE = D2 - 24V PNP (SINKING) (0V A) VOLTAGE = D1 - 24V NPN (SOURCING) (24V A) RESTART SIGNAL = R - 24V ACTIVE HIGH...
ROCON LLC SET-UP PROCEDURE Configuring the Engineering Units In order to configure the engineering units (GPM or LPM), proceed as follows: 1. Press and hold the MENU pushbutton, the display shows “---”. Continue holding the pushbutton for at least 5 seconds.
Page 12
ROCON LLC Note: Flow fault occurs when flow =< setpoint. The LED display starts blinking to indicate this. After the occurrence of a flow fault, the unit must be restarted. If in bypass mode, the alarm signal returns to normal when flow > setpoint + hysteresis (display stops blinking).
ROCON LLC UNIT VERIFICATION Initial Water Flow Present to Operate 1. Confirm that the hoses to weld gun arms are hose-dressed properly. Refer to the INSTALLATION section of this manual. 2. Open the water shut-off ball valves to weld gun arms or cell.
ROCON LLC TROUBLESHOOTING Unit Will Not Power Up 1. Make sure the power cable is correctly plugged into the unit. The DeltaPoint Uno flowmeter display shows a 3-digit number (bright-red digits). It may or may not be flashing. 2. Check the connector on J4 (see...
ROCON LLC Check to determine if air is trapped in the cooling water circuit. Remove the hoses TO CELL and FROM Cell. Attach a 5-foot plastic (see-through) loop hose between TO CELL and FROM CELL on the unit. Power up the unit. Use a flashlight to look through the plastic hose and see if air bubbles are present in the water line.
ROCON LLC 2. Check the solenoid interrupt line (Pin 6 of the receptacle) and make sure it is low. 3. Check the jumper settings on JP2, JP4 and JP5. Make sure they are all set for “Active Low.” Flowmeter See TROUBLESHOOTING, “Unit Will Not Start”, to ensure sufficient water flow is available for flowmeter to operate.
3. Install new coil, push spring clip inward over coil and plug in DIN connector to coil. 4. Test to determine if coil is operational. 5. If there are problems, contact Service Department at Rocon LLC - 248-542-9635. Clean Diaphragm Orifice / Plunger Pilot Hole Tools required: #4 Allen wrench, 22 mm Open End Wrench 1.
13. With the spring clip pulled, slide the coil over the guide. When complete, push the spring clip over the coil. 14. Insert the DIN connector into the coil. 15. Energize coil to confirm operation. If there is a problem, consult Service Department at Rocon LLC. Override Stem Broken Spare Part: # 2705-CAP If the override stem is broken, replace the control cover.
ROCON LLC MODEL CODES DeltaPoint Jr EXAMPLE : XXXXD Port/Pipe Size Port/Pipe Size 4 Digit Number assigned at Factory FLOW SWITCH RANGE in Inches NPT in Inches NPT followed by alpha code: for Supply and for Pipes To Symbol Return Lines...
2.96 2.96 2.96 2.98 3.96 3.95 3.98 3.99 Based on the above results, there is no difference in performance in the installation of a 90 degree fitting in the inlet port of the flow switch on the DeltaPoint Jr unit.
ROCON LLC RMA NOTICE RMA NOTICE RETURN MATERIAL AUTHORIZATION Please read the following UFM policy information carefully. By following the guidelines outlined below you will assist in providing a timely evaluation and response regarding the status of your flow meter. UFM evaluates all AUTHORIZED RETURNED MATERIALS in a timely manner and will promptly provide notification regarding the status of the related materials and/or a written quotation indicating the total charges and description of the necessary repairs.