Advertisement

Quick Links

Operating Instructions
R A D I O S E N S O R
Heavy Duty TAG
Bluetooth sensor module
R a i l V e h i c l e s

Advertisement

Table of Contents
loading

Summary of Contents for ZF Heavy Duty TAG

  • Page 1 Operating Instructions R A D I O S E N S O R Heavy Duty TAG Bluetooth sensor module R a i l V e h i c l e s...
  • Page 2 This document is protected by copyright. Complete or partial reproduction or distribution of this document is not permitted without the approval of ZF Friedrichshafen AG. Infringements lead to civil and criminal prosecution. This document is a translation of the German original.
  • Page 3: Table Of Contents

    Table of Contents Preface ........................Validity and field of application ...................... Safety ......................... Signal words and symbols ......................General safety instructions ......................Product-specific safety instructions ....................2.3.1 Screw connection ..........................Description ......................... Brief product description ......................... Technical Data ......................Data sheet ............................
  • Page 4: Preface

    Preface Preface In addition to the ZF documentation, observe the provisions of the vehicle manufacturer or the body manufacturer. Validity and field of application This documentation applies to the following add-on device: • Heavy Duty TAG (radio sensor) EN 6075.758.101a - 2021-11...
  • Page 5: Safety

    Safety Safety Signal words and symbols This document contains particularly highlighted safety instructions which are marked with one of the following signal words depending on the severity of the danger. DANGER The signal word DANGER indicates a dangerous situation that, if not prevented, will lead to a severe injury or death.
  • Page 6: General Safety Instructions

    Intended use The ZF product is exclusively intended for the application as defined in the contract and as agreed on the time of delivery. Any other or extended form of use does not comply with this definition of intended use.
  • Page 7 Safety Handling of ZF product Unauthorized changes and modifications might impair functional security. Changes, modifications and applications are only permissible upon written approval by ZF Friedrichshafen AG. Observe the following when working on the ZF product: • Secure workspace. • Only carry out work at the unit when in a voltage-free state.
  • Page 8: Product-Specific Safety Instructions

    • Do not open the ZF product or the batteries. Opening or modifying the ZF product or the batteries will damage the safety devices. This may cause heat or smoke to develop or cause the product or batteries to ignite or explode.
  • Page 9: Screw Connection

    Safety • The firefighters may find instructions on what to bear in mind in the case of fire useful. • If large quantities of smoke or gas develop or are emitted, leave the affected area immediately. • Seek medical help in case of smoke and/or gas inhalation or respiratory tract irritation. •...
  • Page 10: Description

    The sensor may be operated in a frequency range from 2,402 MHz to 2,480 MHz. Function The sensor and the overall system will only function in combination with further ZF Friedrichshafen AG components. For more information, please talk to your ZF contact or visit www.zf.com/hd-tag.
  • Page 11: Technical Data

    The sensor comes with a 1-year warranty. During the warranty period, any defects that can be proven to result from material defects or manufacturing defects will be remedied by replacing or reworking the defective parts. ZF reserves the right to decide on how to remedy the defects. Type plate Position of type plate The type plate is located on the side of the housing.
  • Page 12: Transport And Storage

    Transport and Storage Transport and Storage Transport Commercial transport of lithium thionyl chloride batteries is subject to the dangerous goods laws. Preparation for transport and transport may only be carried out by trained persons and the process must be monitored by qualified experts or companies. 5.1.1 General transport instructions Lithium thionyl chloride batteries are subject to the following dangerous goods regulations and exemptions...
  • Page 13: Storage

    • Exemptions must be approved in advance by the appropriate national authority of the state of origin of the batteries and the state of the operator (airline). Storage The ZF product may not be stored under conditions that do not correspond to the specified technical data (refer to Chapter Technical Data) . Observe the following: •...
  • Page 14: Decommissioning

    In case the ZF product is damaged, please inform ZF Customer Service. If damaged, the batteries inside the ZF product may develop intense heat or cause a fire. In case of damage, the product may also release hazardous gases or leak hazardous liquids.
  • Page 15 The batteries may only be removed for disposal by trained specialized staff. The ZF product may only be opened for disposal by trained specialized staff. Once opened, the ZF product may not be started-up again. Once the product has been opened, the (refer to Section Product-specific safety instructions) .
  • Page 16: Installation

    Installation Installation Preparatory activities The sensor may only be installed by trained qualified staff and in accordance with the provisions and specifications provided by the vehicle manufacturer or operator. Installation location When installing the sensor, make sure that the installation location is protected from damage such as stone chipping or other mechanical impacts.
  • Page 17 Installation 30.3 Ø 10_010641_01_en Fig. 3 Sensor Clean the contact surfaces on the vehicle. Remove grease or other residues from the thread holes. Check the sensor for damage and install the sensor. • Applying threadlockers, such as Loctite, or installing additional thread locking elements is not permitted.
  • Page 18: Maintenance

    Maintenance Maintenance Checking the sensor The sensor is maintenance-free. • In case of potential, exposed installation positions, for example positions close to the track ballast, the sensor must be checked for damage regularly. (refer to Section Product-specific safety instructions) , (refer to Section •...
  • Page 19: Annex

    Annex Annex Overview of revisions Index Date of issue Initiator 2021-11 IBRD1 Dept. Tab. 2 Edition EN 6075.758.101a - 2021-11...
  • Page 22 ZF Friedrichshafen AG 88038 Friedrichshafen Deutschland · Germany Telefon/Phone +49 7541 77-0 Telefax/Fax +49 7541 77-908 000 www.zf.com...

Table of Contents